Wiring Connection

Keep electrical and transducer cables away
from alternator or other noise generating elec-
trical cables. Avoid connecting the instrument
to power circuits that share loads with ignition,
alternators, inverters and radio transmitters.
Electrical power supply connections should
always be as short as possible.
FUJI 5-PIN
CONNECTOR
Installation of the fuel flow trans-
ducer
The fuel flow transducer is designed for in-
stallation in Coast Guard approved 9.5 mm
(
/
") flexible fuel line. The transducer MUST be
3
8
installed AFTER the main fuel filter. It should be
located well away from any area where it will be
effected by excessive heat or vibration from the
engine. It is preferable to mount the transducer in
a vertical position.
8
BRACKET
Northstar
F210 Installation and Operation Manual
Connect the red wire to the positive supply
via a 1 amp fuse or a 1 amp circuit breaker.
Connect the black wire to the electrical
ground.
Connect the fuel flow transducer to the five
pin transducer inlet cable.
BUZZER
600mm (24")
POWER CORD
RED
(+) TERMINAL
Drain all the fuel from the flexible fuel line. Cut the
fuel line and using the fuel hose fixing clips provided
install the transducer so that the FUEL IN side of
the transducer connects to the fuel tank.
BLACK
(-) TERMINAL