External Device Output Terminal (OUT)
The external device output terminal consists of a pair of two output terminals (OUT). There is no
distinction between " + " and " - " for OUT. The NC Viewer switches the 2 output terminals to
disconnected or connected condition. The output terminals use photo couplers and are separate
from the internal circuit in the VB-C300.
Loads connected to the output terminals should be within the following ratings:
Internal Connection Chart
The wire appropriate for external device cable is as follows.
AWG: # 28 - # 22
Tip
Conductor diameter:
Rating across the output terminals: Up to 50 VDC
Continuous load current: 100 mA or less