TEST
IDEAL RANGE
Free Chlorine
1.0 - 3.0 ppm
pH
7.2 - 7.8
Alkalinity
80 - 120 ppm
Salt
2700 - 3400 ppm Add salt as required to increase.
Stabilizer
60 - 80 ppm
Calcium
200 - 400 ppm
Electrolytic Cell inspect & clean
620 Division St.
Elizabeth, NJ 07207
ADJUSTMENT REQUIRED
Raise desired output % to
increase, lower desired output %
to decrease -OR- increase or
decrease pump filtration time.
Too high - add muriatic acid
Too low - add soda ash.
Add baking soda to increase.
Add acid as required to decrease.
Add cyanuric acid to increase.
Add calcium to increase.
Drain and add water to decrease.
Refer to section in manual.
092360D RevF
Copyright © 2010 Hayward
Aqua Plus
Automation and Chlorination
Operation Manual
for models
PL-PLUS
PL-PLUS-20
®
www.haywardnet.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aqua Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for Hayward Aqua Plus

  • Page 1 200 - 400 ppm Add calcium to increase. Drain and add water to decrease. Electrolytic Cell inspect & clean Refer to section in manual. Operation Manual for models PL-PLUS PL-PLUS-20 092360D RevF 620 Division St. www.haywardnet.com Elizabeth, NJ 07207 Copyright © 2010 Hayward...
  • Page 2: Important Safety Instructions

    LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Rite, Aqua Rite Pro, Aqua Plus and SwimPure chlorination products to be free of defects in materials and workmanship, under normal use and service, for a period of three (3) years.
  • Page 3: Table Of Contents

    Operate the Spa - Automatically.......... 24 Set the Heater Temperature..........24 Available displays depend on configuration. If you call the Hayward Technical Service Dept. for assistance, they may ask for the software revisions of both the main unit and each of the display/ Set the Chlorinator Output ...........
  • Page 4: Automation

    Manual. Aspects of the Aqua Plus that pertain to system setup are not covered in this manual. Automation The Aqua Plus can control up to 4 high voltage (120/240V) pieces of equipment, up to 3 automatic valve actua- tors, and a conventional and solar heater. Both manual and automatic (programmed) operation are available. All of the control functions can be programmed at a display/keypad which is part of the main unit (typically located near the pool equipment) or at one or more remote display/keypads.
  • Page 5: Default Display

    Default Display below: Turn power on at the main panel and turn the Aqua Plus control power circuit breaker on. The keypad will show the default display. The default display alternates between the day/time, air and pool (or spa) temperature, pool/ spa sanitizer setting, and salt level.
  • Page 6: Filter Pump

    • No Cell Power -- If no chlorinator cell power is detected on the printed circuit board. While the main objective of the Aqua Plus is to automate the operation of your pool/spa system, there may be certain times when you want to override the automatic operation and control the equipment manually. To operate •...
  • Page 7: Pool/Spa Valves

    • Inspect Cell -- For optimum operation, you will need to inspect the Aqua Plus chlorinator cell approximately every 3 months and clean the cell if necessary. The Aqua Plus will automatically remind you when it is time and External Input Interlock: display “Inspect Cell, + to reset”...
  • Page 8: Using The Programming Buttons

    Press the “MENU” button to get to the desired menu. Multiple pushes of the button will Menu If you are in an area that only experiences occasional freezing conditions, your Aqua Plus system may be set up to rotate through all 6 menus and return to the starting point.
  • Page 9: Programming Menu Flowchart

    Programming Menu Flowchart The Aqua Plus’s six menus have many items that allow you to customize the operation of your pool/spa equipment. The chart below shows the Aqua Plus’s menus as well as each menu’s specific settings. default menu day and time...
  • Page 10: Settings Menu

    The Default Menu is a series of informative displays (temperatures, salt levels, chlorinator settings, etc.) with nothing to set. The Aqua Plus will automatically switch to the default menu when no keys have been pressed for 2 minutes and will then scroll through each display.
  • Page 11 At the end of the super chlorinate period, chlorine production. A high salt level can cause the Aqua Plus to stop chlorinating. The salt in your pool/spa is the pool will return to normal operation.
  • Page 12: General Water Chemistry

    General Water Chemistry Salt is required only if you are using the chlorinator features on the Aqua Plus Control. If you are NOT using the chlorinator, it is recommended that you follow all of the other chemistry recommendations besides salt. Refer to the...
  • Page 13: Timers Menu

    4. Press “+” or “-“ to toggle between “on” and “off” This menu will only appear if a wireless base station is connected to the Aqua Plus. Perform this procedure each time a wireless remote control is added to the Aqua Plus system. During this proce- dure the wireless remote “learns”...
  • Page 14 Move between start and stop times & to previous/next menu item heater will start. This operation is the highest priority and will take precedence over other automatically programmed operations. At the end of the spa period, the Aqua Plus will return Filter T2-wkend...
  • Page 15 Move to previous/next menu item spa time, the Aqua Plus will turn on the filter pump and move the pool/spa valves into the “spa-only” position. The heater will automatically heat the spa up to the programmed spa temperature (page 7).
  • Page 16 6B A, Button 1 This menu allows the user to map each button of the AQL-SS-6B to one of the standard Aqua Plus For larger pools or when you have an unusually high bather load, a large amount of rain, a cloudy functions.
  • Page 17 AIR temperature falls sensor falls below the selected freeze temperature threshold, If “Pool Only” is selected, then the Aqua Plus will switch the pool/spa valves to the “pool only” the Aqua Plus will turn on the valve to allow circulation of the water. IMPORTANT: this only enables operation of the valve3 output during freeze--see the “Filter Pump Config.”...
  • Page 18 Aux1 Pump Speed Aqua Plus will turn on the filter pump to circulate the water. If “Pool and Spa” is selected in the Pool/ This is the speed of the filter pump when the Aux1 output is on. The default selection is “Settings Spa sub-menu (see page 18), the valves will also alternate between the pool and spa every 30 minutes Menu”.
  • Page 19 This feature ensures that the heater cools down before water circulation is stopped. When enabled, timer and timeclock functions the Aqua Plus will continue to run the filter pump for 5 minutes after the heater turns off. During this Aux1 Relay Toggle between Standard (default), Dimmer and VSP period the filter pump LED will flash and also a “Heater Cooldown, X:XX remaining”...
  • Page 20 Allow Low Speed Low Speed of a 2-speed Filter Pump – the Aqua Plus will turn on the lights relay whenever the low speed operation of the filter pump is required. It is very important that the “2-speed” filter pump This menu only appears if the pool filter is configured for 2-speed operation.