❶
Select the mounting location.
Mounting Location Guidelines
• 2.3 m (7'6") mounting height
• Avoid direct or reflected sunlight
• Aim sensor away from windows or heating/
cooling devices
• Sensor must have a clear line-of-sight to
protected area
❹
Wire the unit.
• Connect wires as shown using 0.64 - 1.63 mm
(14 to 22 AWG) wire size. Observe proper
polarity.
❷
Separate the sensor housings and re-
move the printed circuit board (PCB).
• Push outward on the
PCB latch and lift the
PCB out of the hous-
ing.
❺
Configure the sensor sensitivity.
POWER
12VDC
Switch
10mA
ALARM
Alarm
16VDC
90mA
LED
TAMPER
30VDC
0.5A
2
•
Configure the IS-215T for the sensitivity best
suited to the application.
SENSITIVITY
High (pulse count 1)
Low [Normal] (pulse count 2)
❸
• Use a small screwdriver to
push in the housing latch
at the bottom of the sensor,
and gently pull apart the
housings.
• Slide the wire through the wire channel and wire
• Mount the back housing flat against a wall or in a
• Replace the PCB.
❻
SWITCH SW2 POSITION
ON
OFF
Mount the unit.
Wiring Knockouts
Corner
Mount
Wire Channel
access in the back housing.
corner.
Walk-test the sensor.
High Sensitivity: 2-4 Steps
(Pulse Count 1)
Low [Normal] Sensitivity: 3-5 Steps
(Pulse Count 2)
Corner
Mount
Wall Mount
Need help?
Do you have a question about the IS-215T and is the answer not in the manual?
Questions and answers