Terry Stacey
February 22, 2025
The wiring diagram on the Honeywell IS312B does not make it clear where power goes in or which connection goes to the security lights. I'm also concerned at the connections being labelled as 12v and 18v not 220v
1 comments:
Mr. Anderson
February 22, 2025
The Honeywell IS312B Passive Infrared Motion Sensor connects to power and security lights using the following wiring:
1. Power Connection: - Connect V+ to the positive 12-18 VDC power supply. - Connect V- to the negative (ground) of the power supply.
2. Security Light Connection: - Use the NC (Normally Closed) and C (Common) terminals for relay output to control the security light. - Connect the security light circuit in series with these terminals, ensuring it matches the voltage and current specifications.
Ensure the power source is EN 60950 Class II Limited Power Source compliant. Always test the installation after connecting.
Page 2
Honeywell is a registered trademark of Kontakta den lokala auktoriserade representanten för Honeywell för produktgarantiinformation. Honeywell International Inc. All other Voor informatie over de productgarantie kunt u het beste contact opnemen met de lokale Honeywell vertegenwoordiging. trademarks are the properties of their 800-18734-04 Rev. D Contatti il suo rappresentante Honeywell per ulteriori informazioni su prodotti e garanzia.
Need help?
Do you have a question about the IS312B and is the answer not in the manual?
Questions and answers
The wiring diagram on the Honeywell IS312B does not make it clear where power goes in or which connection goes to the security lights. I'm also concerned at the connections being labelled as 12v and 18v not 220v
The Honeywell IS312B Passive Infrared Motion Sensor connects to power and security lights using the following wiring:
1. Power Connection:
- Connect V+ to the positive 12-18 VDC power supply.
- Connect V- to the negative (ground) of the power supply.
2. Security Light Connection:
- Use the NC (Normally Closed) and C (Common) terminals for relay output to control the security light.
- Connect the security light circuit in series with these terminals, ensuring it matches the voltage and current specifications.
Ensure the power source is EN 60950 Class II Limited Power Source compliant. Always test the installation after connecting.