NI PCI-7030/6533E
High Speed Digital I/O RT Board
A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
• C r i t i c a l a n d e x p e d i t e d s e r v i c e s
• I n s t o c k / R e a d y - t o - s h i p
Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate, representative, or authorized distributor for any manufacturer listed herein.
In Stock
New From Surplus Stock
Open Web Page
https://www.artisantg.com/55339-1
• We b u y y o u r e x c e s s , u n d e r u t i l i z e d , a n d i d l e e q u i p me n t
• F u l l - s e r v i c e , i n d e p e n d e n t r e p a i r c e n t e r

Advertisement

loading
Need help?

Need help?

Do you have a question about the PCI-7030 and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments PCI-7030

  • Page 1 NI PCI-7030/6533E High Speed Digital I/O RT Board In Stock New From Surplus Stock Open Web Page https://www.artisantg.com/55339-1 A l l t r a d e m a r k s , b r a n d n a m e s , a n d b r a n d s a p p e a r i n g h e r e i n a r e t h e p r o p e r t y o f t h e i r r e s p e c t i v e o w n e r s .
  • Page 2 RT Series DAQ Device User Manual RT Series DAQ Device User Manual April 2001 Edition Part Number 322635B-01...
  • Page 3 Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545 For further support information, see the Technical Support Resources appendix. To comment on the documentation, send e-mail to techpubs@ni.com © Copyright 1999, 2001 National Instruments Corporation. All rights reserved.
  • Page 4 Any action against National Instruments must be brought within one year after the cause of action accrues. National Instruments shall not be liable for any delay in performance due to causes beyond its reasonable control.
  • Page 5 Classification requirements are the same for the Federal Communications Commission (FCC) and the Canadian Department of Communications (DOC). Changes or modifications not expressly approved by National Instruments could void the user’s authority to operate the equipment under the FCC Rules.
  • Page 6 interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. •...
  • Page 7 Chapter 4 LabVIEW RT Programming Targeting LabVIEW RT and Downloading VIs............4-1 Resetting the RT Series DAQ Device .............4-2 Creating Stand-Alone Executables ................4-2 Embedded Applications...................4-2 Command-Line Arguments ................4-2 Programming LabVIEW RT..................4-3 © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 8 Contents Real-Time Programming ....................4-4 Running a VI at Time-Critical Priority without the RT Development System ................... 4-4 Use of Shared Memory ................... 4-4 Configuration Issues ..................4-4 RT Series DAQ VIs....................... 4-5 Appendix A Specifications Appendix B Technical Support Resources Glossary Index RT Series DAQ Device User Manual...
  • Page 9 Text in this font denotes text or characters that you should enter from the monospace keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 10 About This Manual programs, subprograms, subroutines, device names, functions, operations, variables, filenames and extensions, and code excerpts. Related Documentation The following documents contain information that you might find helpful as you read this manual: • LabVIEW Real-Time User Manual • LabVIEW Real-Time Release Notes •...
  • Page 11 DAQ daughterboard. The processor board contains a microprocessor that runs real-time, embedded LabVIEW RT applications. The RT Series DAQ device provides the same high-performance data acquisition as other National Instruments DAQ devices. For example, the PXI-7030/6040E contains a DAQ device that is equivalent to the PXI-6040E.
  • Page 12 PXI-7030/6040E PXI E Series User Manual PXI-7030/6030E PXI E Series User Manual PXI-7030/6533 DIO 6533 User Manual PCI-7030/6040E PCI E Series User Manual PCI-7030/6030E PCI E Series User Manual PCI-7030/6533 DIO 6533 User Manual What You Need to Get Started To set up and use your RT Series DAQ device, you need the following: ❑...
  • Page 13 LabVIEW RT installation. Refer to the LabVIEW Real-Time Release Notes for specific information about LabVIEW RT and NI-DAQ version compatibility. Refer to Chapter 2, Installation and Configuration, for information about installing your RT Series hardware. © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 14 Visually verify the installation. Make sure the board is not touching other boards or components and is fully inserted in the slot. Replace the cover. Plug in and turn on your computer. © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 15 Your RT Series DAQ device is installed. You are now ready to configure your software. Board Configuration Because of the National Instruments standard architecture for data acquisition and the PCI and PXI bus specifications, the RT Series DAQ devices are completely software configurable.
  • Page 16 PC. You do not need to test the resource configuration, because National Instruments configures the DAQ daughterboard, and the resources do not change. In addition, applications run on the host PC cannot access the DAQ © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 17 Chapter 2 Installation and Configuration daughterboard directly, even though the DAQ daughterboard is configured as a separate device. Only LabVIEW RT applications targeted to the RT Series DAQ device can access the DAQ daughterboard. If you want to test whether the DAQ daughterboard is working, run any DAQ example that ships with LabVIEW RT.
  • Page 18 RT Series DAQ hardware. The following sections describe the components that make up the RT Series DAQ hardware. 1 Processor Board 2 DAQ Daughterboard Figure 3-1. PCI RT Series Data Acquisition Hardware © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 19 Chapter 3 Hardware Overview 1 Processor Board 2 DAQ Daughterboard Figure 3-2. PXI RT Series Data Acquisition Hardware Processor Board The 7030 processor board contains a microprocessor and support circuitry, as shown in Figure 3-3. The support circuitry includes a chipset with PCI controller and ISA bridge, main memory (DRAM), L2 cache (SRAM), and BIOS.
  • Page 20 Embedded CPU Bus ISA Bridge Cache Memory BIOS SRAM/DRAM Controller PCI Controller Embedded ISA Bus Shared Memory BIOS MITE Interface Extension Shared Memory I/O Daughterboard Figure 3-3. RT Series Processor Board Diagram © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 21 DAQ Daughterboard The daughterboard in the RT Series system provides the DAQ functionality. Each daughterboard is a National Instruments DAQ device with some mechanical modifications to allow it to connect to the processor board. You can expect the same high performance and specifications from the daughterboard that you do from the standard version of the device.
  • Page 22 On the PXI-7030 device, the LEDs are visible on the front panel. Because the LEDs are located along the top edge of the device on the PCI-7030, you must remove the cover from the case of your computer to view them.
  • Page 23 Select Target Platform dialog box to reset the RT Series DAQ device. Any VIs you previously downloaded to the RT Series DAQ device are aborted and unloaded from memory. Click Configure in the © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 24 Chapter 4 LabVIEW RT Programming Select Target Platform dialog box to launch MAX and configure your RT Series DAQ devices. Resetting the RT Series DAQ Device Resetting the RT Series DAQ device is necessary only after you first turn on the system or if communication with the RT Engine cannot be established or has been lost.
  • Page 25 If you attempt to download to and run on your target platform a VI that has any of the unsupported functionality listed above, the VI still executes. Unsupported functions do not work and return standard LabVIEW error codes. © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 26 Chapter 4 LabVIEW RT Programming Real-Time Programming This section provides an overview of real-time programming using your RT Series DAQ hardware. Running a VI at Time-Critical Priority without the RT Development System Instead of using TCP/IP or VI Server to communicate data to a host PC application, you can maximize real-time VI performance on RT Series DAQ devices by peeking and poking data to shared memory.
  • Page 27 RT Series DAQ device. Refer to the PID Control for G Reference Manual for more information about the PID Control and Fuzzy Logic VIs. © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 28 On-chip cache ........16 KB write-back L2 cache ..........256 KB write-back Floating-point unit........Yes Host-Embedded Communication Shared Memory Type ............SRAM Size............1 KB user available Bus Interface Type ............PCI Slave © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 29 To calculate the total power requirement, add the processor board requirement from Note this section to the I/O board requirement given in the I/O board manual. Physical Dimensions (Not Including Connectors) PCI-7030..........312.9 by 160.5 cm (12.3 by 4.2 in.) One PCI slot PXI-7030 ..........16 by 10 cm (6.3 by 3.9 in.)
  • Page 30 Technical Support Resources Web Support National Instruments Web support is your first stop for help in solving installation, configuration, and application problems and questions. Online problem-solving and diagnostic resources include frequently asked questions, knowledge bases, product-specific troubleshooting wizards, manuals, drivers, software updates, and more. Web support is available through the Technical Support section of ni.com...
  • Page 31 Appendix B Technical Support Resources Worldwide Support National Instruments has offices located around the world to help address your support needs. You can access our branch office Web sites from the Worldwide Offices section of . Branch office Web sites provide ni.com...
  • Page 32 (2) collecting and measuring the same kinds of electrical signals with A/D and/or DIO boards plugged into a computer, and possibly generating control signals with D/A and/or DIO boards in the same computer © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 33 Glossary device Instrument or controller that is addressable as a single entity and controls or monitors real-world I/O points. A device is often connected to the host computer through some type of communication network or can be a plug-in device. For data acquisition (DAQ) applications, a DAQ device is inside your computer or attached directly to the parallel port of your computer.
  • Page 34 Glossary VISA virtual instrument software architecture—a new driver software architecture developed by National Instruments to unify instrumentation software GPIB, DAQ, and VXI. It has been accepted as a standard for VXI by the VXIplug&play Systems Alliance. © National Instruments Corporation...
  • Page 35 (note), 2-1 devices and corresponding manual unpacking RT Series DAQ devices, 1-3 (table), 1-2 related documentation, x downloading VIs, 4-1 to 4-2 LabVIEW functions not supported on DAQ hardware, 4-3 © National Instruments Corporation RT Series DAQ Device User Manual...
  • Page 36 Index LabVIEW RT programming, 4-1 to 4-5 processor board, 3-2 to 3-3 creating stand-alone executables, board diagram, 3-3 4-2 to 4-3 description, 3-2 downloading VIs, 4-1 to 4-2 specifications, A-1 LabVIEW functions not supported on programming. See LabVIEW RT DAQ hardware, 4-3 programming.
  • Page 37 4-2 to 4-3 command-line arguments, 4-2 to 4-3 embedded applications, 4-2 system integration, by National Web support from National Instruments, B-1 Instruments, B-1 Worldwide technical support, B-2 targeting LabVIEW RT, 4-1 to 4-2 technical support resources, B-1 to B-2 ©...

This manual is also suitable for:

Rt seriesPci-6040ePci-6030ePci-6533Pxi-7030