7.3.2 LED description
The single LED indicates the operational status of inverter.
LED Designation
Color
Status
Green
ON
Green
Blink
POWER
Green
Blink
Green
Blink
Green
Blink
Green
ON
Green
Blink
Green
Blink
COMM
Green
Blink
Green
Blink
Blank
ON
Green
ON
Green
Blink
BAT
Green
Blink
Green
Blink
Blank
ON
Red
ON
FAULT
Red
Blink
Red
ON
The LED combination indicate the operational status of inverter.
LED Designation
Color
Status
POWER
Green
ON
BAT
Green
ON
COMM
Green
ON
FAULT
Red
ON
POWER
Green
Blink
BAT
Green
Blink
COMM
Green
Blink
FAULT
Red
Blink
POWER
Green
Blink
BAT
Green
ON
BAT
Green
Blink
COMM
Green
Blink
41
Action
Message
steady
Feed in grid
3s on/1s off
DC ON/AC OFF
1s on/3s off
DC OFF/AC ON
0.5s on/0.5s off
synchronizing with grid
2s on/2s off
standby mode
steady
BAT is in normal operation
1s on/3s off
BAT is in low power
0.5s on/0.5s off
BAT is in fault mode
1s on/1s off
BAT interal comm. Fail
2s on/2s off
BAT is in standby mode
steady
No BAT , PV inverter mode
steady
4G/WiFi,local WiFi ok
0.5s on/0.5s off
Local WiFi connecting
1s on/1s off
WiFi/ 4G fail,Local WiFi ok
1s on/3s off
Local WiFi fail,4G/WiFi ok
steady
Comm. Fail
steady
Arc Fault(with the buzzer on)
1s on/1s off
Warning
steady
Fault
Action
Message
In sequence
DSP Firmware Update
1s on/1s off
M3 Firmware Update
3s on/1s off
Backup mode
steady
1s on/1s off
BAT internal comm. Fai
7.4 Powering off the system
Ø
After the inverter powers off, the remaining electricity and heat may
still cause electric shock and burns. After power-off, wait 5 minutes
before servicing the inverter. Always wear protective gloves when
servicing the inverter.
Ø
If the inverter is connected to the battery, ensure that a shutdown
command is sent from the APP. Power off the system after the inverter has
WARNING
shut down. If no shutdown command is sent from the app, the inverter
will shut down after the power grid is off, the inverter will wait for
meanwhile, then charge the battery by solar power and the inverter enter
off grid mode.
Ø
Power off both Grid, PV and Battery totally, can shut down the system.
Ø
Send a shutdown command from the APP. for details, see the Operations on the
Shinephone APP.
Ø
Turn off the AC switch between the inverter and the power grid.
Ø
Turn off the DC switch at the bottom of the inverter.
Ø
If a battery connects to the battery port of the inverter, power off the battery.
Ø
The system is shutdown.
7.5 Button
7.5.1 Reset button
There is a button located inside the wiring box. for this button,there are the The
ffollowing functions are for reset botton:
Button
Application
Arc reset
Clear arc fault
If there is no arc fault, run arc
Arc self-test
self-test
Gateway reset to factory
Gateway reset
status
Fig 7.2
Trigger condition
Press the button for 3-5 seconds
Press the button for 3-5 seconds
Press the button for more than 10
seconds
42

Advertisement

loading
Need help?

Need help?

Do you have a question about the MIN 8200TL-XH-US and is the answer not in the manual?

Questions and answers