Omconfig Chassis Temps - Dell Command Line Interface User Manual

Dell command line interface user's guide
Table of Contents

Advertisement

Table 4-13. omconfig chassis remoteaccess config=user id=<user id> dracusergroup=custom
name=value pair 1
name=value pair 2
config=user
id=user id
(continued)
dracusergroup=custom

omconfig chassis temps

Use the omconfig chassis temps command to set warning thresholds for temperature probes. As with
other components, you can view both warning and failure threshold values, but you cannot set failure
thresholds. Your system's manufacturer sets the minimum and maximum failure thresholds.
NOTE:
Settable thresholds vary from one system configuration to another.
Valid Parameters for Temperature Warning Thresholds
Table 4-14 shows the valid parameters for setting temperature warning thresholds:
Table 4-14. omconfig chassis temps
name=value pair
index=<n>
warnthresh=default
minwarnthresh=<n>
maxwarnthresh=<n>
84
omconfig: Managing Components Using the Instrumentation Service
name=value pair 3
logindrac= true | false
configuredrac= true | false
configure users= true | false
clearlogs= true | false
executeservercommands=
true | false
accessconsoleredir= true |
false
accessvirtualmedia= true |
false
testalerts= true | false
Description
Number of the probe or probe index (must be specified).
Sets minimum and maximum warning thresholds to default.
Minimum warning threshold (1 decimal place).
Maximum warning threshold (1 decimal place).
Description
true/false: Enables/disables
logging into DRAC.
true/false: Enables/disables
configuration of DRAC.
true/false: Enables/disables
configuration of users.
true/false: Enables/disables
log clearance.
true/false: Enables/disables
execution of server commands.
true/false: Enables/disables access
to console redirection.
true/false: Enables/disables access
to virtual media.
true/false: Enables/disables
test alerts.