Omconfig Chassis Fans - Dell Command Line Interface User Manual

Dell command line interface user's guide
Table of Contents

Advertisement

Default Minimum and Maximum Warning Thresholds
If you want to set both the upper and lower current warning threshold values to the recommended
default value, type:
omconfig chassis currents index=0 warnthresh=default
You cannot default one value and set another. In other words, if you default the minimum warning
threshold value, you are also selecting the default value for the maximum warning threshold value.
Specify a Value for Minimum and Maximum Warning Thresholds
If you prefer to specify values for the current probe warning thresholds, you must specify the number of
the probe you are configuring and the minimum and/or maximum warning threshold values. In the
following example, the probe that is being configured is probe 0:
omconfig chassis currents index=0 minwarnthresh=3.310 maxwarnthresh=
3.381
When you issue the command and the system sets the values you specify, the following message appears:
Current probe warning threshold(s) set successfully.

omconfig chassis fans

Use the omconfig chassis fans command to set fan probe warning thresholds. As with other components,
you can view both warning and failure threshold values, but you cannot set failure thresholds.
Your system's manufacturer sets the minimum and maximum failure thresholds.
Valid Parameters for Fan Warning Thresholds
Table 4-6 shows the valid parameters for setting fan warning thresholds:
Table 4-6. omconfig chassis fans
name=value pair
index=<n>
warnthresh=default
minwarnthresh=<n>
maxwarnthresh=<n>
Default Minimum and Maximum Warning Thresholds
NOTE:
Systems that contain ESM3, ESM4, and BMC capabilities do not allow you to set warning threshold values
to default values.
If you want to set both the upper and lower fan warning threshold values to the recommended default
value, type:
omconfig chassis fans index=0 warnthresh=default
Description
Number of the probe or probe index (must be specified).
Sets minimum and maximum warning thresholds to default.
Minimum warning threshold.
Maximum warning threshold.
omconfig: Managing Components Using the Instrumentation Service
71