Download Print this page

Wilder Technologies OSFP 1.6T User Manual

Test adapters

Advertisement

Quick Links

OSFP 1.6T Test Adapter User Manual
OSFP 1.6T
Test Adapters
Preliminary User Manual
P a g e
| 1
©2024 Wilder Technologies, LLC
Document No. 910-0079-000 Rev. B

Advertisement

loading
Need help?

Need help?

Do you have a question about the OSFP 1.6T and is the answer not in the manual?

Questions and answers

Summary of Contents for Wilder Technologies OSFP 1.6T

  • Page 1 OSFP 1.6T Test Adapter User Manual OSFP 1.6T Test Adapters Preliminary User Manual P a g e ©2024 Wilder Technologies, LLC Document No. 910-0079-000 Rev. B...
  • Page 2 Electrical Responses ........................32 Wilder OSFP 1.6T HCB Response ....................32 Wilder OSFP 1.6T MCB Response ....................33 Wilder OSFP 1.6T Typical MTF Response .................. 34 Wilder OSFP 1.6T ICN ........................ 39 Compliance with Environmental Legislation ................. 40 WEEE Compliance Statement ....................40 Compliance To RoHS 2 Substance Restrictions .................
  • Page 3 640-1176-100 (OSFP-1.6T-TPA1.00-MCB-RHS-RC) Cooling Module, and Riding Heat Sink The OSFP 1.6T HCB (Plug) and OSFP 1.6T MCB (Receptacle) TPAs, shown in Figures 1 and 2 below, test 224 Gbps PAM4 OSFP interface cables, hosts, and modules to the requirements of the OSFP MSA and IEEE 802.3dj™/D1.2 standards.
  • Page 4 OSFP 1.6T Test Adapter User Manual OSFP-1.6T-TPA1.XX-HCB-P The OSFP 1.6T Host Compliance Test Adapter can be used for testing the compliance of OSFP Host Devices to the OSFP MSA and IEEE 802.3dj™/D1.2 standards. 32x 1.85mm or 1.00mm Female Connectors for...
  • Page 5 OSFP 1.6T Test Adapter User Manual OSFP-1.6T-TPA1.XX-MCB-R The OSFP 1.6T Module Compliance Board can be used for testing the compliance of the OSFP MSA and IEEE 802.3dj™/D1.2 standards. 32x 1.85mm or 1.00mm Female Connectors for High- Speed Testing USB Type-C, I...
  • Page 6 Pasternack Part Number PE8259 NOTE: RF Terminators may be required to support specific user test configurations. (Some RF Terminators may be optionally ordered from Wilder Technologies or refer to the following table for purchasing options). RF Terminator Specifications and Source Information...
  • Page 7 (per OSFP MSA). The Cooling Module is required when testing OSFP modules at power classes 4 or greater. The Cooling Module is shipped disassembled from the OSFP 1.6T MCB TPA. To install the cooling module onto the MCB, slide the cooling module assembly onto the mounting rail guide until the assembly clicks in place on the rail.
  • Page 8 “OSFP MSA Specification for OSFP Octal Small Form Factor Pluggable Module, Rev 5.0, October 2 , 2022” Outside Case Temperature Outside Handle Temperature Figure 4. OSFP 1.6T MCB with DUT Temperature locations (Cooling Module not shown). P a g e ©2024 Wilder Technologies, LLC Document No. 910-0079-000 Rev. B...
  • Page 9 OSFP 1.6T Test Adapter User Manual Module Type 1. OSFP Open Top Heat Sink Module (Fin Type) Thermal Measurements Figure 5. OSFP Open Top Heat Sink Module (Fin Type). Table 1. OSFP Open Top Heat Sink Module Thermal Data with Cooling Module...
  • Page 10 OSFP 1.6T Test Adapter User Manual Module Type 2. OSFP Closed Top Heat Sink Module (Tunnel Type) Thermal Measurements Figure 6. OSFP Closed Top Heat Sink Module (Tunnel Type). Table 2. OSFP Closed Top Heat Sink Module Thermal Data with Cooling Module...
  • Page 11 Figure 7. Caution Label, IEC 60417. Caution, Hot Surface Cooling Module Usage Recommendations and Thermal Safety Precautions While testing an OSFP device module with the OSFP 1.6T MCB TPA, the test operator should adhere to the following usage recommendations and thermal safety precautions. •...
  • Page 12 Retain the outer cardboard shipping container until the contents of the shipment have been inspected for completeness and the product has been checked mechanically and electrically. Use the foam-lined instrument-case for secure storage of the Wilder Technologies OSFP Test Adapter when not in use.
  • Page 13 OSFP 1.6T Test Adapter User Manual The OSFP Test Adapter Care and Handling Precautions The OSFP Test Adapters require careful handling to avoid damage. Improper handling techniques, or using too small a cable bend radius, can damage the coaxial cable connections within the adapter housing or the cables themselves.
  • Page 14 OSFP 1.6T Test Adapter User Manual • CAUTION 5: Carefully Make High-Speed (1.85mm and 1.00mm) Connections To connect the OSFP TPA High-Speed connectors, follow these steps: 1. Hold the cable stationary by grasping the cable at the heat shrink label section near the connector.
  • Page 15 OSFP 1.6T Test Adapter User Manual General Test Adapter, Cable, and Connector Observing simple precautions can ensure accurate and reliable measurements. Handling and Storage Before each use of the OSFP TPA, ensure that all connectors are clean. Handle all cables carefully and store the OSFP TPA in the foam-lined instrument case when not in use.
  • Page 16 OSFP 1.6T Test Adapter User Manual Electrostatic Discharge Information Protection against electrostatic discharge (ESD) is essential while connecting, inspecting, or cleaning the OSFP TPA test adapter and connectors attached to a static-sensitive circuit (such as those found in test sets).
  • Page 17 Figure 8. OSFP 1.6T MCB User Model In this configuration, the OSFP 1.6T MCB is used to test an OSFP Module. The MCB must be powered by an external source, either with the provided 12V power supply, or with the 3.3V banana plug jacks.
  • Page 18 OSFP 1.6T Test Adapter User Manual Closeup of MCB Interface and Functional Ports Power Indicator Power Source Input – DC power USB-C to I C – USB-C will Jack and banana sockets provided allow users to access I for preferred power input.
  • Page 19 Two Wire Interface. To access this information, use the Wilder Technologies CMIS GUI software. Installation and instructions are in the CMIS GUI user manual (910-0070-000). This manual is provided on USB Flash Drive supplied with the OSFP MCB product.
  • Page 20 *DC blocks are accessories and are not provided with this product Figure 10. OSFP 1.6T HCB User Model In this configuration, the OSFP 1.6T HCB is used to test an OSFP Host. An RX signal, inputted from a connected Signal Generator, is transferred through the HCB’s RX lines into the OSFP host under test.
  • Page 21 The OSFP TPA’s have Touchstone S4P files for de-embedding the electrical length and losses within the TPA up to the OSFP connector interface pads. (Contact Wilder Technologies, support@wilder-tech.com, to obtain a copy of the S4P files.) The Touchstone S4P files enable...
  • Page 22 OSFP 1.6T Test Adapter User Manual Mechanical and Environmental Specifications NOTE: All specifications in this manual are subject to change. Table 3. General Specifications ITEM DESCRIPTION Usage Environment Controlled indoor environment HCB (Plug) Test Adapter Length (w/ 1.85mm coax) 327.7 mm (12.9 inches) (Characteristic) 304.8 mm (12.0 inches)
  • Page 23 OSFP 1.6T Test Adapter User Manual Table 4. OSFP-1.6T-TPA1.XX-HCB-P: 8-Position Cable Connector (Low-Speed). LABEL PIN NO. COLOR ID FOR HCB DESCRIPTION Pin 1 Grey SDA, I C Data for DDC, Serial Data Line Pin 2 Purple Signal (RF Ground) and Supply (Power) Common...
  • Page 24 OSFP 1.6T Test Adapter User Manual Table 5. OSFP-1.6T-TPA1.XX-HCB-P (Plug) Pin Assignements Connector Color Color ID for Data Pin Description Destination (HCB) Identification Line Polarity Number (HCB) Coax Shield and Ground See Table 4 P2 Pin 2,4, and 8 Tx2p...
  • Page 25 OSFP 1.6T Test Adapter User Manual Coax Shield and Ground Black Insulation P2 Pin 2,4, and 8 Rx1n Rx1- Black Yellow Rx1p Rx1+ Yellow Coax Shield and Ground See Table 4 P2 Pin 2,4, and 8 Coax Shield and Ground...
  • Page 26 OSFP 1.6T Test Adapter User Manual Tx3n Tx3- Black White/Green Tx3p Tx3+ White/Green Coax Shield and Ground See Table 4 P2 Pin 2,4, and 8 Tx1n Tx1- Black White/Yellow Tx1p Tx1+ White/Yellow Coax Shield and Ground See Table 4 P2 Pin 2,4, and 8...
  • Page 27 OSFP 1.6T Test Adapter User Manual OSFP-1.6T-TPA1.XX-MCB-R (Receptacle) Cable Pin-out The OSFP-1.6T-TPA1.XX-MCB-R test adapter provides thirty-two 1.85mm or 1.00mm connectors (eight lanes of primary differential signals) to access all OSFP high-speed signals. Labels clearly mark each cable or connector. The following figure refers to the pin-description tables for the OSFP-1.6T-TPA1.XX-MCB-R (Receptacle) test adapter.
  • Page 28 OSFP 1.6T Test Adapter User Manual Table 6. OSFP-1.6T-TPA1.XX-MCB-R (CONN6) 20-Position Fixture-Mounted Connector (Low-Speed) LABEL PIN NO. DESCRIPTION INT-RSTn Pin 1 Interrupt Pin 2 No Connection Pin 3 No Connection Pin 4 No Connection Pin 5 No Connection Pin 6...
  • Page 29 OSFP 1.6T Test Adapter User Manual Table 7. OSFP-1.6T-TPA1.XX-MCB-R (Receptacle) Pin Assignements Connector Color Color ID for Data Pin Description Destination (MCB) Identification Line Polarity Number (MCB) Coax Shield and Ground CONN 6 Pin 17,19 Tx2p Tx2+ White/Blue Tx2n Tx2-...
  • Page 30 OSFP 1.6T Test Adapter User Manual Coax Shield and Ground Black Insulation CONN 6 Pin 17,19 Rx1n Rx1- Black Yellow Rx1p Rx1+ Yellow Coax Shield and Ground CONN 6 Pin 17,19 Coax Shield and Ground J2 Pin 1 Rx2p Rx2+...
  • Page 31 OSFP 1.6T Test Adapter User Manual Tx3n Tx3- Black White/Green Tx3p Tx3+ White/Green Coax Shield and Ground CONN 6 Pin 17,19 Tx1n Tx1- Black White/Yellow Tx1p Tx1+ White/Yellow Coax Shield and Ground CONN 6 Pin 17,19 P a g e | 31 ©2024 Wilder Technologies, LLC...
  • Page 32 Documented in the following pages are the electrical responses of the Wilder Technologies OSFP 1.6T TPAs. HCB loss, MCB loss, and MTF response data is shown. The following data is pending upon ratification of the final specification: ICN, ERL, and other electrical responses and limits.
  • Page 33 OSFP 1.6T Test Adapter User Manual Wilder OSFP 1.6T MCB Response Figure 14. Plot of OSFP 1.6T MCB Insertion Loss The loss of the MCB up to but excluding the connector and its associated PCB pads is plotted in Figure 14. Note that the IEEE 802.3dj™/D1.2 specification states that the difference between reference and MCB response should be accounted for in the measurement.
  • Page 34 OSFP 1.6T Test Adapter User Manual Wilder OSFP 1.6T Typical MTF Response Figure 15. Plot of OSFP 1.6T Mated Differential Insertion Loss Response P a g e | 34 ©2024 Wilder Technologies, LLC Document No. 910-0079-000 Rev. B...
  • Page 35 OSFP 1.6T Test Adapter User Manual Figure 16. Plot of OSFP 1.6T Mated Differential Return Loss Response MTF RLoss is shown for information only. P a g e | 35 ©2024 Wilder Technologies, LLC Document No. 910-0079-000 Rev. B...
  • Page 36 OSFP 1.6T Test Adapter User Manual Figure 17. Plot of OSFP 1.6T Mated Test Fixture Differential Return Loss MTF RLoss is shown for information only. P a g e | 36 ©2024 Wilder Technologies, LLC Document No. 910-0079-000 Rev. B...
  • Page 37 OSFP 1.6T Test Adapter User Manual Figure 18. Plot of OSFP 1.6T MTF Common Mode Return Loss Figure 19. Plot of OSFP 1.6T MTF Conversion Return Loss P a g e | 37 ©2024 Wilder Technologies, LLC Document No. 910-0079-000 Rev. B...
  • Page 38 OSFP 1.6T Test Adapter User Manual Figure 20. Plot of OSFP 1.6T MTF Conversion Insertion Loss P a g e | 38 ©2024 Wilder Technologies, LLC Document No. 910-0079-000 Rev. B...
  • Page 39 OSFP 1.6T Test Adapter User Manual Wilder OSFP 1.6T ICN TX victim is on HCB side and aggressors for TX victim are TX1in-TX[n]in on MCB (excluding thru channel) and TX1in-TX[n]in on MCB which make up the FEXT and NEXT responses, respectively.
  • Page 40 European Union Directive 2002/96/EC on waste electrical and electronic equipment ("WEEE Directive"). As a service to our customers, Wilder Technologies is also available for managing the proper recycling and/or disposal of all Wilder Technologies products that have reached the end of their useful life.
  • Page 41 OSFP 1.6T Test Adapter User Manual Glossary of Terms TERMINOLOGY DEFINITION A signal imposed on a system (i.e., cable assembly) to measure response on Aggressor other signal carriers. Decibel (dB) Ten times the common logarithm (i.e. log10) of the ratio of relative powers.
  • Page 42 OSFP 1.6T Test Adapter User Manual Index 224 Gbps PAM4, 3 OSFP Open Top Heat Sink Module with DUT AC coupled, 6 Temperature Locations, 9 Cable Bend Limits, 13 OSFP-TPA-HCB Test Adapter (Plug), 22 Cable Tension (Pull Forces), 13 OSFP-TPA-MCB-R (Receptacle) Test Adapter, 27...
  • Page 44 Visit our website at www.wilder-tech.com Wilder Technologies, LLC 11201 NE 9th St. Vancouver WA, 98684 Phone: 360-859-3041 Fax: 360-859-3105 www.wilder-tech.com ©2024 Wilder Technologies, LLC Document No. 910-0079-000 Rev. B Date Created: 10/25/2024 inprotected.com...