CONTROL BOX
METHOD FOR CREATING CROWN ROAD SURFACE
You can create the Crown road surface.
When you select "Set Start Point and Main-fall"
Set the starting point.
1.
Lower the bucket edge to the ground at an arbitrary place,
tap "Measure Point" button (1) or tap "Select" button (2) to
select a point, and show the Point Coordinates.
(1) Grade
2.
Tap the items (3) of "Direction", "Grade", and "Length" on
"Main-fall", and input the values.
3.
Tap the item (4) of "Cross-fall Grade" and input the value
of "Cross-fall Grade".
4.
Tap the item (5) of "Width of road", and input the width of
road.
5.
Tap "Exit" button (6), and the screen changes to "Message
Box" screen.
To reflect the created Surface to the currently setting Sur-
face, tap the ENTER button. Not to reflect it to the current-
ly setting Surface, tap the RETURN button.
REMARK
On this screen, even if you tap the ENTER button, the set-
ting will not be completed.
6.
The screen changes to the editing screen of Surface. Tap
the ENTER button. The creation of Surface is completed.
7.
Tap the RETURN button on the editing screen of Surface,
and the creation of Surface is canceled.
REMARK
For the operation procedure of the Surface editing screen,
see "METHOD FOR EDITING SURFACES".
7-50
Measure
SETTING
G0056201