Table of contents Foreword Safety Precautions Warning Attention Safety About Your Heat Pump Transportation Accessories Features Operating range Introduction of different modes Technical parameter Dimension Installation Guidance Installation reminder Warning Electric wiring diagram Operation Guidance Key Function Screen Display Operation Instruction Testing Inspect heat pump before use Leakage detection notice and method...
A. Foreward Thank you for choosing our inverter pool heat pump which is designed for a more silent and energy saving user experience. It is an ideal way for green pool heating. We hope you'll enjoy using our heat pumps. Thank you!
B. Safety Precautions We have provided important safety messages in this manual and on your heat pump. Please always read and obey all safety messages. Environment friendly R32 Refrigerant is used for this heat pump. 1. Warning The WARNING sign denotes a hazard. It calls attention to a procedure, practice, or the like, which, if not correctly performed or adhered to, could result in personal injury or injury to a third party.
2. Attention a. Please read the following instructions before installation, use and maintenance. b. Installation must be done by professional staff only in accordance with this manual. c. A leakage test must be performed after installation. d. Except for the methods recommended by the manufacturer, do not use any methods to accelerate the defrosting process or clean the frosted parts.
C. About your heat pump 1. Transportation a. Always keep upright b. Do not lift the water union (Otherwise, the titanium heat exchanger may be damaged) 2. Accessories 3. Features Turbo fan DC Twin-rotary inverter compressor DC Brushless fan motor EEV Technology Reverse cycle defrosting with 4-way valve High efficiency twisted titanium heat exchanger...
4. Operating Range To provide you comfort and pleasure, please set swimming pool water temperature efficiently and economically. a. The heat pump can work between air -15°C~43°C, b. Temperature of heating 18°C~40°C c. Temperature of cooling 12°C~30°C Ideal operation range is between air 15°C ~ 25°C. 5.
7. Dimensions Size(mm) Name Model MPC220 MPC270 1135 MPC320 1029 1107 MPC320s 1029 1107 MPC410s 1139 1106 ※ Above data is subject to modification without notice. Note: The above swimming pool heat pump specification drawing is for installation reference only to technical staff.
D. Installation Guidance 1. Installation Reminder Only professional staff are allowed to install the heat pump. The users are not qualified to install by themselves, otherwise the heat pump might become damaged and unsafe for a users’ safety. a. Installation distance, drainpipe installation and water pipe connection The inverter pool heat pump should be installed in a good, ventilated place.
Page 11
water outlet Chlorinator cell valve (or other treatment) By-pass Filter valve water water inlet return valve Filtration Pool pump Important: Adjust By-pass valve to correct pool water volume (page 6) 1) The frame must be fixed by bolts (M10) to a concrete foundation or brackets. The concrete foundation must be solid and fastened;...
2. Warning Connect to an appropriate power supply, the voltage should comply with the rated voltage of the products. The heat pump must be earthed. Wiring must be handled by a professional technician according to the circuit diagram. Set leakage protector according to the local code for wiring (leakage operating current ≤ 30mA). The layout of the power cable and signal cable should be orderly and not affecting each other;...
Page 13
4. References for Protecting Devices and Cable Specification MODEL MPC220 MPC270 MPC320 MPC320S MPC410S Rated Current (A) Rated Breaker Residual Action Current (mA) Fuse (A) Power Cord (mm 5x2.5 5x2.5 Signal Cable (mm 3×0.5 3×0.5 3x0.5 3x0.5 3x0.5 Maximum Current (A) 10.5 ※...
E. Operation Guidance 1. Key Function Symbol Heating & cooling modes Power On/Off Wi-Fi setting Lock/Unlock Screen Heating mode (18-40°C) Cooling mode (12-30°C) Auto mode (12-40°C) Power Perfect Silence 1. Temperature Setting Attention: The controller has a power-down memory function. The buttons will turn dark when it’s locked.
2. Screen Display a. Plugged without turning on b. Power on Heating mode Cooling mode Auto mode Running speed percentage Wi-Fi connection Inlet Outlet...
3. Operation Instructions a. Screen Lock 1) There is an automatic screen lock function. No operation for more than 30 seconds, the screen will automatically lock and the screen will dim while the lock button will light on and the other button light will be off. 2) Press “...
Page 17
e. Power/Perfect/ Silence mode Heating mode: Press “ ” to switch among Power mode , Perfect mode and Silence mode Cooling and Auto mode: only support Power mode , Perfect mode f. Operating Frequency Compressor icon lights on during operation. Operation frequency speed will show on screen as below: Frequency percentage g.
Page 18
h. Defrosting 1) Automatic defrosting: When machine is auto defrosting, will flash, and return to previous working mode when it finishes. 2) Manual Defrosting: To enter forced defrosting mode, the compressor must be working for more than 10 minutes. in heating mode, press “ ”...
F. Testing 1. Inspect Heat Pump Before Use a. The ventilating device and outlets are operating adequately and are not obstructed. b. It’s prohibited to install refrigeration pipe or components in a corrosive environment. c. Inspect the electric wiring on basis of the electric wiring diagram and earthing connection. d.
G. Maintenance – (SUMMER) - for a Service Technician “CUT OFF” the power supply to the heat pump before cleaning or servicing. In the Summer season, we recommend the evaporator coil/condenser is periodically cleaned by a service technician to prevent clogging and enhance the efficiency of the heat pump. 1.
Page 21
Maintenance (WINTER) – Homeowner “CUT OFF” power supply of the heat pump before cleaning, examination and repairing 4. In the winter season when the pool is no longer in use: a. Cut off the power supply to prevent any machine damage. b.
Trouble Shooting for Common Faults 1. Repairing Guidance WARNING: a. If repair or scrap is required, please contact authorised service centre nearby. b. Requirements for Service Personnel. Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry-recognised assessment specification.
Page 23
2. Failure Solution and Code Failure Reason Solution When powered on, the This is not a failure. Please Startup code controller displays a code wait until it disappears. Refer to the manual to Unresponsive controller Some models have screen lock function. unlock the screen Improper operation Refer to the manual...
Page 24
Protection & Failure code Display Protection Code Description No water protection Power supply excesses operation range (not a failure) Excessive temp difference between inlet and outlet water (Insufficient water flow protection) Ambient temperature too high or too low protection (not a failure) Anti-freezing reminder (not a failure) Display Failure Code Description...
Water Pump Control Connection Water pump: 230V voltage, ≤500W capacity Breaker/fuse (Customer prepare) Power cord Earthing Power Supply 230V~/50Hz Water Pump Customer remote control switch connector Breaker/fuse Water Pump (Customer prepare) Power Supply 230V~/50Hz Earthing...
Page 26
Water pump: 230V voltage, >500W capacity Breaker/fuse Power cord (Customer prepare) Earthing Power Supply 230V~/50Hz Water Pump Customer remote control switch connector Breaker/fuse Water Pump (Customer prepare) Contactor Power Supply 230V~/50Hz Earthing...
Page 27
Water pump: 400V voltage Breaker/fuse (Customer prepare) Power Supply Power cord 400V~/50Hz Earthing Water Pump Customer remote control switch connector Water Pump Breaker/fuse (Customer prepare) Contactor Power Supply 400V~/50Hz Earthing...
Page 28
Water Pump Control and Timer Connection 1: Water pump timer 2: Water pump wiring of Heat Pump Note: The installer should connect 1 parallel with 2 (as above picture). To start the water pump, condition 1 or 2 is connected. To stop the water pump, both 1 and 2 should be disconnected.
Page 29
WARRANTY 5/12 YEAR LIMITED WARRANTY – Mr Perfect is supplied with a 5-Year Parts only Warranty extended to 12-Years on the Heat Exchanger and Compressor. Applicable to UK Mainland only. The liability of the manufacturer shall not exceed the repair or replacement of defective parts and does not include 1) any costs for labour to remove and reinstall the defective part, 2) transport costs to and from the factory and 3) any other materials required to make the repair.
Page 30
(If later than sales receipt/invoice , signed documentation from pool/refrigerant required). Please do not attempt to modify or mend a fault without prior permission as this may invalidate the warranty. To register your warranty or make a claim, please go to www.paramountpools.co.uk and search for Aquark Heat Pump.
Wi-Fi Operation InverGo Download Account Registration Register by e-mail or third-party application. Android a. E-mail registration.
Page 32
b. Register through third-party application Create Family Please set family name and choose location of device.
Page 33
APP Pairing a. With Bluetooth 1. Please confirm that you’re connected to Wi-Fi and your Bluetooth is on. 2. Click “Add Device”, and then follow the instructions to pair device.
Page 34
b. With Wi-Fi 1. Please make sure you are connected to Wi-Fi. 2. Press " " for 3 seconds to unlock the screen. Press “ ” for 3 seconds and release. After hearing “Beep”, enter Wi-Fi password in app. During connection, “ ”...
Page 35
Operation 1. For heat pump with Heating function only: Compressor Indicate Power/ speed Perfect/ Silence mode °C/°F switch Setting Inlet water temperature temperature Query Select Power/ Perfect/ Silence Mode Timer On/Off 2. For heat pump with Heating & Cooling function: Compressor Indicate Power/ speed...
Page 36
Share Devices to Your Family Members After pairing, if your family members also want to control the device, please let your family members register “InverGo” first, and then the administrator can operate as below: Notice: Weather forecast is just for reference. App is subject to updates without notice.