  • Page 1 INSTALLATION & USER MANUAL POOL HEAT PUMPS INVERX20 TURBO SILENCE Please read this user’s manual carefully to ensure proper use, installation and maintenance Ithomis Str. 6, Chalandri, GR-15231, Athens - Greece Τel: 210 6715510 / 211 7007269/ 211 7007270 Fax: 2106542877 Website: www.ecofer.com.gr...
  • Page 2: Table Of Contents

    Installation and user manual SUMMARY FOR USERS ……………………………………………………………………....P.3-P.12 1. GENERAL INFORMATION 1.1. Contents 1.2. Operating conditions and range 1.3. Advantages of different modes 1.4. Kind reminder 2. OPERATIONS 2.1. Notice before using 2.2. Operation instructions 2.3. Advanced application 2.4. Daily maintenance and winterizing 3.
  • Page 3 Installation and user manual Warning a. Please read the following tips before installation, use and maintenance. b. Installation, removal and maintenance must be carried out by Professional in accordance with the instructions. c. Gas leakage test must be done before and after installation. 1.
  • Page 4 Installation and user manual d. Installation must be stopped if any gas leakage, and the unit must be returned to professional maintenance center. 3. Transportation and Storage a. Sealing is not allowed during transportation b. Transporting goods at a constant speed is needed to avoid sudden acceleration or sudden braking, so as to reduce the collision of goods.
  • Page 5: General Information

    Installation and user manual 1. GENERAL INFORMATION 1.1. Contents After unpacking, please check if you have all the following components. NOTICE: Please install the water unions step by step. STEP 1 STEP 3 STEP 2 1.2. Operating conditions and range ITEMS RANGE Operating range...
  • Page 6: Advantages Of Different Modes

    Installation and user manual 1.3. Advantages of different modes The heat pump has three modes: Turbo, Smart and Silence. They have different advantages under different conditions. MODE ADVANTAGES Heating capacity: 120%~20% Turbo mode Fast heating, intelligent optimization according to ambient temperature and water temperature Energy efficiently saving Heating capacity:100%~20% Smart mode...
  • Page 7 Installation and user manual 1.4.4. Do not put anything into the inlet or outlet, and do not remove the fan cover and the running fan to avoid injury. 1.4.5. Don’t use or store combustible gas or liquid such as thinners, paint and fuel to avoid fire. 1.4.6.
  • Page 8: Operations

    Installation and user manual 1.4.9. Please note that the following codes are not failure. CODES No water protection Anti-Freezing Protection Out of the operating range Insufficient water flow protection Power abnormal 2. OPERATIONS 2.1. Notice before using 2.1.1. For longer service life, please ensure water pump is on before heat pump starts to work, and water pump is off after heat pump is off.
  • Page 9 Installation and user manual Note: will be light all the time when power is ① Standby screen display: When the screen is locked, the key lamp will be off. Will show 0.00 when standby “ ” ② Screen lock: a. If no operation in 30 seconds, screen will be locked. b.
  • Page 10: Advanced Application

    Installation and user manual Water outlet 1. Power On: Press for 3 seconds to light up screen, then press to power on heat pump. 2. Adjust Set Temperature: When screen is unlocked, press to display or adjust the set temperature. 3.
  • Page 11 Installation and user manual mode, press to quit “Parameter Checking” status. 2.3.3. Parameter list Content Adjust range Step length 0: Continuous 1: Water temp control Water Pump Running Way 2: Time/water temp control Time Setting (Only available when the 10 ~ 120 min 5 min water pump running way is set to “2”)
  • Page 12: Daily Maintenance And Winterizing

    Installation and user manual Electronic expansion valve opening DC fan speed (r/min) 2.4. Daily maintenance and winterizing 2.4.1. Daily Maintenance Please don’t forget to cut off power supply of the heat pump ➢ Please clean the heat pump with household detergents or clean water, NEVER use gasoline, thinners or any similar fuel.
  • Page 13: Technical Specification

    Installation and user manual 3. TECHNICAL SPECIFICATION Model X20-09 X20-11 X20-14 X20-16 X20-18 Advised pool volume (m 18~35 25~40 30~50 35~60 40~65 Working air temp (° C) -20 ~43 Performance Condition: Air 28°C , Water 26°C , Humidity 80% Heating capacity (kW) in Turbo mode 10.1 12.2 14.9...
  • Page 14 Installation and user manual Model X20-22 X20-26 X20-32 X20-32T X20-40T Advised pool volume (m 45~75 55~90 65~105 65~105 75~120 Working air temp (° C) -20 ~43 Performance Condition: Air 28°C , Water 26°C , Humidity 80% Heating capacity (kW) in Turbo mode 23.4 28.2 34.1...
  • Page 15: Transportation

    Installation and user manual 1. TRANSPORTATION 1.1. When storing or moving the heat pump, the heat pump should be at the upright position. 1.2. When moving the heat pump, do not lift the water unions since the titanium heat exchanger inside the heat pump will be damaged. 2.
  • Page 16 Installation and user manual 2.2. Installation instruction 2.2.1. Location and size To avoid air recirculation, the heat pump should be installed in a place with good ventilation or should reserve sufficient space for installation and maintenance. Please refer to the schema below: * MINIMUM DISTANCE Filter...
  • Page 17 Installation and user manual UNIT=MM X20-09 X20-11 X20-14 X20-16 1045 X20-18 1045 X20-22 1195 X20-26 1072 X20-32 1264 X20-32T 1264 X20-40T 1364 ※ Above data is subject to modification without notice. 2.2.2. Heat pump installation. ➢ The frame must be fixed by bolts (M10) to concrete foundation or brackets. The concrete foundation must be solid;...
  • Page 18 Installation and user manual 1. Connecting your power wire  Please use cross screwdriver to take off the 2 screws at the bottom of the right side panel. Take off the lower half of the panel.  Unscrew the 4 screws on the cover of the electrical box.
  • Page 19 Installation and user manual NOTE: Must be hard wired, no plug allowed. For your safe use in winter, it’s strongly recommended to equip heating priority function.  For the detailed wiring diagram, please refer to Appendix 1.  3. Options for protecting devices and cable specification MODEL X20-09 X20-11...
  • Page 20 Installation and user manual ➢ After the water pump starts, please make sure no leakage of water. Then power on and press the ON/OFF button of the heat pump, and set desired temperature. ➢ In order to protect the heat pump, the heat pump is equipped with start delay function. When starting the heat pump, the fan will start to run in 3 minutes, in another 30 seconds, the compressor will start to run.
  • Page 21: Trouble Shooting For Common Faults

    Installation and user manual 3. TROUBLE SHOOTING FOR COMMON FAULTS FAILURE REASON SOLUTION No power Wait until the power recovers Power switch is off Switch on the power Heat pump doesn’t run Fuse burned Check and change the fuse The breaker is off Check and turn on the breaker evaporator blocked Remove the obstacles...
  • Page 22: Failure Code

    Installation and user manual 4. FAILURE CODE DISPLAY NOT FAILUREDESCRIPTION No water protection Power supply excesses operation range Excessive temp difference between inlet and outlet water (Insufficient water flow protection) Ambient temperature too high or too low protection Anti-freezing reminder Customer Control Switch DIN2 Disconnect Display Failure description...
  • Page 23: Appendix 1: Heating Priority Wiring Diagram (Optional)

    Installation and user manual APPENDIX 1: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL)
  • Page 24: Appendix 2: Heating Priority Wiring Diagram (Optional)

    Installation and user manual APPENDIX 2: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL)
  • Page 25: Appendix 3: Heating Priority Wiring Diagram (Optional)

    Installation and user manual APPENDIX 3: HEATING PRIORITY WIRING DIAGRAM (OPTIONAL) Parallel connection with filtration timer If the user wants to connect the water pump timer, the installer should connect water pump timer and water pump wiring of heat pump in parallel. So that water pump can start when water pump timer or water pump wiring of heat pump is connected, and water pump will only be switched off when both are disconnected at the same time.
  • Page 26: Wi-Fi Setting

    Installation and user manual 5. WI-FI SETTING 5.1. APP Download Android Mobile please download from iPhone please download from 5.2. Account registration a) Registration by Cell phone number/Email...
  • Page 27 Installation and user manual b) Cell phone number registration 5.3. Create family Please set a name for the family and choose the room of the device.
  • Page 28 Installation and user manual 5.4. Three methods of device binding Please connect your phone to the Wi-Fi network first. 5.4.1. Auto Discovery (Bluetooth) a) Please make sure the Bluetooth function is enabled on your phone. b) Press for 3 seconds after the screen unlock, will be flashing rapidly to enter Wi-Fi binding status.
  • Page 29 Installation and user manual 5.4.2. EZ Mode (Easy-connect) a) Activate the Wi-Fi module b) Press for 3 seconds after the screen unlocks, will be flashing rapidly to enter Wi-Fi binding status. c) Click "Add device", and follow the instructions below to finish binding. display on the screen once the Wi-Fi connection success.
  • Page 30 Installation and user manual 5.4.3. AP Mode Activate Wi-Fi module a) Press for 10 seconds after the screen unlock, will be flashing slowly to enter Wi-Fi binding status. b) Click "Add device", and follow the instructions below to finish binding. display on the screen once the Wi-Fi connection success.
  • Page 31 Installation and user manual 5.5. Operation instructions The following instructions are for heat pumps with heating function only. More share device Heating capacity percentage Indicate the working status Real-time power consumption Switching °C/°F The current swimming pool water temp Setting temp Temp adjustment slider Cloud Timer Turbo/Smart/Silence Selection...
  • Page 32 Installation and user manual 5.6. Share devices with your family members After binding, if your family members also want to control the device. Please let your family members register the APP first, and then the administrator can operate as below (The following pictures are for reference only): Then your family members will see this heat pump once they log in to the APP.
  • Page 33 Thank you for choosing Fairland TurboSilence Inverter. The factory reserves the final interpretation right. And keep the right to stop or change product specification and design without prior notice at any time, no need to bear the resulting obligations. Version: Gg3XPr32...