Hide thumbs Also See for SLICE6 AIR:

Advertisement

Quick Links

SLICE6 AIR DAS
User's Manual
July 2024
13006-90440-MAN (Rev. 3)
© Diversified Technical Systems, Inc. All Rights Reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLICE6 AIR and is the answer not in the manual?

Questions and answers

Summary of Contents for DTS SLICE6 AIR

  • Page 1 SLICE6 AIR DAS User’s Manual July 2024 13006-90440-MAN (Rev. 3) © Diversified Technical Systems, Inc. All Rights Reserved.
  • Page 2: Table Of Contents

    DTS Support ........................4 Introducing the SLICE6 AIR DAS ..................5 SLICE6 AIR DAS Module (chassis isolated) ..............5 SLICE6 AIR DAS Module - Ethernet Recorder (EDR) ............. 6 Sensor Interface ......................... 7 Supported Sensor Types ....................7 Input Range ........................7 Excitation Sources ......................
  • Page 3 Data Streaming ......................20 IRIG ........................... 20 Appendix A: Hardware Specifications ................21 Mechanical Specifications, Connector Information and Pin Assignments ...... 21 SLICE6 AIR Input Impedance ..................29 UART RS232/RS422 Connections ................31 Ethernet Chaining ......................31 Accessories/Support Equipment ..................32 Appendix B: Hardware Configuration Specifications ..........
  • Page 4: Dts Support

    DTS has support engineers worldwide with extensive product knowledge and crash test experience to help via telephone, e-mail or on-site visits. The best way to contact a DTS support engineer is to submit a request through the DTS Help Center portal (support.dtsweb.com).
  • Page 5: Introducing The Slice6 Air Das

    July 2024 Introducing the SLICE6 AIR DAS SWaP optimized, the SLICE6 AIR DAS is a complete data acquisition unit for measuring analog signals in extreme environments such as payload ejection/deployment; in-flight/on- board UAVs/drones, rockets, missiles and munitions; and biomechanics. PTPv2 Ethernet communications with on-board data storage to flash memory are supported.
  • Page 6: Slice6 Air Das Module - Ethernet Recorder (Edr)

    July 2024 SLICE6 AIR DAS Module - Ethernet Recorder (EDR) The SLICE6 AIR Ethernet Recorder module is a SLICE6 AIR DAS module with firmware that supports recording Ethernet traffic (up to 10 Mbps UDP) instead of analog (sensor) data. DataPRO version 3.4 or greater is required. Details for its use can be found on the Help...
  • Page 7: Sensor Interface

    SLICE6 AIR DAS Sensor Interface Supported Sensor Types The SLICE6 AIR DAS supports many types of sensors including accelerometers, load cells and pressure sensors. The following general sensor types are supported: • Full- bridge (4-wire) or half-bridge (3-wire) resistive and piezo-resistive sensors, •...
  • Page 8: Excitation Sources

    Shunt Emulation The SLICE6 AIR DAS contains a shunt emulation circuit, effectively eliminating the need for conventional shunt resistors to perform shunt checks. When “Emulation” is chosen as the shunt calibration method, the software injects a precisely calculated current into the sensor to create an expected deflection of the sensor’s output.
  • Page 9: System Connector

    • UART-based GPS/1PPS 3, 4 • IRIG-B122/B022. When operating as a PTP master clock, SLICE6 AIR DAS communicates with slave units to provide clock synchronization. When operating as a slave unit, the DAS synchronizes its internal clock with the grandmaster/master clock.
  • Page 10: Power Management

    Help Center here. Power Management The SLICE6 AIR DAS and DS-4 do not contain an internal battery and must be connected to external power at all times for operation. Without external power applied, the DAS is in a power off state.
  • Page 11: Power-Up And Power-Down Procedures

    July 2024 Power-up and Power-down Procedures When sufficient power is applied, the SLICE6 AIR DAS will power up (on, idle and communi- cation enabled) if an ON signal is present. With power applied but the ON signal absent, the unit is off. Power up (On state) occurs in ~15 s, after which communication is enabled.
  • Page 12: Leds

    SLICE6 AIR DAS User’s Manual July 2024 LEDs The SLICE6 AIR DAS has two LED indicators that show system and power status. Status (STS) LED The status LED indicates communication and arm status and is red, green or blue. At system power up, the LED cycles from red to green to blue followed immediately by the power LED boot-up sequence.
  • Page 13: Power (Pwr) Led

    SLICE6 AIR DAS User’s Manual July 2024 Power (PWR) LED The power LED is red, green or blue. Condition Power up Connected to host Power up; not connected to host (time synchronization is disabled DAS synchronized with time input source (0.5 Hz)
  • Page 14: Data Memory Size

    July 2024 Data Memory Size With 15 GB of flash memory available for data storage, the SLICE6 AIR DAS can record ~52 minutes of data at the maximum sampling rate (6 channels at 400,000 sps). Since the recording capacity is very large, it is generally best to limit sampling rates and event durations to the minimum necessary to avoid large and cumbersome data files.
  • Page 15: Slice6 Air Ds-4

    Appendix A. For power requirements, please see page 10. Information on Ethernet chaining is on page 31. Contact DTS if you have any questions about using multiple systems in your test environment. WARNING: Testing using the DS-4 should only be performed with the DAS retainer cap securely fastened (6.6 in-lb).
  • Page 16: Basic Care And Handling

    Shock Rating The SLICE6 AIR DAS and DS-4 are rated for 500 g, 4 ms half-sine duration, in all axes. (A 5000 g option for the SLICE6 AIR DAS module is available.)
  • Page 17: Environmental Rating

    SLICE6 AIR in your environment, please contact DTS. Environmental Rating The SLICE6 AIR DAS module is IP64 rated. The DS-4 and all accessories are not IP rated. 6 (solid ingress) = totally protected against dust;...
  • Page 18: Software

    The discussion below provides a general introduction to data collection. Please see the software manual for a detailed discussion and implementation specifics. The SLICE6 AIR DAS is a standalone data logger. Once the system is armed, the PC can be disconnected if desired.
  • Page 19: Hybrid Recorder Mode

    The SLICE6 AIR DAS can be placed in an auto-arm mode that will cause the unit to arm automatically when the power is cycled. This available with any available data collection mode.
  • Page 20: Data Streaming

    SLICE6 AIR DAS User’s Manual July 2024 Finally, if the SLICE6 AIR DAS remains connected to the PC during data collection, the control software can be used to initiate data collection. The table below summarizes the data collection modes and event/triggering options.
  • Page 21: Appendix A: Hardware Specifications

    All copyright, patent, and ownership rights are retained. This information shall not be disclosed, Manufacture/fabricate to meet the EU RoHS Directive reproduced in whole or in part, or used for manufacture without prior written consent from DTS. 2011/65/EU and RoHS Annex II phthalates...
  • Page 22 Manufacture/fabricate to meet the EU RoHS Directive ADDED INPUT CONNECTOR PINOUT AND ADDITIONAL INFO 2020-10-27 JC reproduced in whole or in part, or used for manufacture without prior written consent from DTS. 2011/65/EU and RoHS Annex II phthalates CORRECTED TORQUE SPEC ON PG.2...
  • Page 23 This drawing contains information that is the property of Diversified Technical Systems, Inc. (DTS). All copyright, patent, and ownership rights are retained. This information shall not be disclosed, reproduced in whole or in part, or used for manufacture without prior written consent from DTS. VELCRO STRAP FOR...
  • Page 24 Manufacture/fabricate to meet the EU RoHS Directive CORRECTED MATERIAL CALLOUT IN TITLE BLOCK 2024-03-06 JC reproduced in whole or in part, or used for manufacture without prior written consent from DTS. 2011/65/EU and RoHS Annex II phthalates 26-POSITION HD D-SUB...
  • Page 25 This drawing contains information that is the property of Diversified Technical Systems, Inc. (DTS). All copyright, patent, and ownership rights are retained. This information shall not be disclosed, reproduced in whole or in part, or used for manufacture without prior written consent from DTS. VELCRO STRAP FOR...
  • Page 26 All copyright, patent, and ownership rights are retained. This information shall not be disclosed, Manufacture/fabricate to meet the EU RoHS Directive reproduced in whole or in part, or used for manufacture without prior written consent from DTS. 2011/65/EU and RoHS Annex II phthalates...
  • Page 27 This drawing contains information that is the property of Diversified Technical Systems, Inc. (DTS). All copyright, patent, and ownership rights are retained. This information shall not be disclosed, reproduced in whole or in part, or used for manufacture without prior written consent from DTS. VELCRO STRAP FOR...
  • Page 28 SLICE6 AIR DAS User’s Manual July 2024 Sensor Connector (looking into the connector) Suggested cable connector P/N: Omnetics A99014-513 (MMDS-513-N-02-SS) (solder cup termination) (DTS P/N 80000-04110-R) Omnetics MMDS-513-N-02-WD* (discrete wires) Signal Voltage Current Signal Voltage Current -SIG_CH1 -0.3 ~ 5.3 V <1 mA...
  • Page 29: Slice6 Air Input Impedance

    SLICE6 AIR DAS User’s Manual July 2024 SLICE6 AIR Input Impedance Note: This only applies to inputs less than 1 PN junction away from ground. If the voltage increases beyond that, the hardware will clip the signal. support.dtsweb.com 13006-90440-MAN (Rev. 3)
  • Page 30 SLICE6 AIR DAS User’s Manual July 2024 System Connector (looking into the connector) Suggested cable connector P/N: Omnetics A98001-025 (MMDP-025-N-02-SS) (solder cup termination) (DTS P/N 80000-04111-R) Omnetics MMDP-025-N-02-WD* (discrete wires) Function Voltage Current +PWR 9 ~ 30 V <150 mA...
  • Page 31: Uart Rs232/Rs422 Connections

    Pin 9 (looking into the connector) Ethernet Chaining To share Ethernet communications, chain SLICE6 AIR DAS modules or DS-4 units together using the methodology in the table below. (Be sure to properly terminate an Ethernet chain.) SLICE6 AIR DAS/DS-4 SLICE6 AIR DAS/DS-4...
  • Page 32: Accessories/Support Equipment

    13006-90570: SLICE6 AIR DAS System Conn Assy (Micro-D 25P conn, backshell, S/R) 13006-90630: Cable, SLICE6 AIR 2-rack daisy chain (SYS port > 2 racks in series) (120") 13006-90690: SLICE6 AIR DAS Sensor Connector Protector Kit 13006-90840: SLICE6 AIR DAS/TSR AIR Test Device...
  • Page 33: Appendix B: Hardware Configuration Specifications

    SLICE6 AIR DAS User’s Manual July 2024 Appendix B: Hardware Configuration Specifications SLICE6 AIR DAS are typically delivered with a default IP address as follows: 192.168.4.xx where xx is based on the last two digits of the S/N; for example: IP address S/N S6A0047 = 192.168.4.47...
  • Page 34 SLICE6 AIR DAS User’s Manual July 2024 2. The software will immediately look for all attached devices and list them in the table. (You may also click to refresh the list.) Current IP address for any selected device will cause the unit’s LED to flash.
  • Page 35 SLICE6 AIR DAS User’s Manual July 2024 4. To enable DHCP, select the check box then select . Proceed to step 7. 5. To disable DHCP and manually enter IP address and other information, unselect the check box. 6. Enter the new parameters and select for each item updated.
  • Page 36: Appendix C: Sensor Interface Wiring Diagrams

    SLICE6 AIR DAS User’s Manual July 2024 Appendix C: Sensor Interface Wiring Diagrams © Diversified Technical Systems, Inc. All Rights Reserved. SLICE6 AIR Sensor Channel Architecture © Diversified Technical Systems, Inc. All Rights Reserved. Bridge Input support.dtsweb.com 13006-90440-MAN (Rev. 3)
  • Page 37 SLICE6 AIR DAS User’s Manual July 2024 © Diversified Technical Systems, Inc. All Rights Reserved. Signal Generator (floating) © Diversified Technical Systems, Inc. All Rights Reserved. Signal Generator (grounded) support.dtsweb.com 13006-90440-MAN (Rev. 3)
  • Page 38 SLICE6 AIR DAS User’s Manual July 2024 © Diversified Technical Systems, Inc. All Rights Reserved. Strain Gage (2-wire) © Diversified Technical Systems, Inc. All Rights Reserved. Strain Gage (3-wire) support.dtsweb.com 13006-90440-MAN (Rev. 3)
  • Page 39 SLICE6 AIR DAS User’s Manual July 2024 © Diversified Technical Systems, Inc. All Rights Reserved. Strain Gage (full bridge) © Diversified Technical Systems, Inc. All Rights Reserved. 3-Wire Potentiometer support.dtsweb.com 13006-90440-MAN (Rev. 3)
  • Page 40 SLICE6 AIR DAS User’s Manual July 2024 © Diversified Technical Systems, Inc. All Rights Reserved. 4-Wire Potentiometer © Diversified Technical Systems, Inc. All Rights Reserved. Accelerometer (3-wire) support.dtsweb.com 13006-90440-MAN (Rev. 3)
  • Page 41 SLICE6 AIR DAS User’s Manual July 2024 © Diversified Technical Systems, Inc. All Rights Reserved. IEPE Accelerometer © Diversified Technical Systems, Inc. All Rights Reserved. Switch Closure support.dtsweb.com 13006-90440-MAN (Rev. 3)
  • Page 42 SLICE6 AIR DAS User’s Manual July 2024 © Diversified Technical Systems, Inc. All Rights Reserved. RTD (4-wire) © Diversified Technical Systems, Inc. All Rights Reserved. Range Expander support.dtsweb.com 13006-90440-MAN (Rev. 3)
  • Page 43 SLICE6 AIR DAS User’s Manual July 2024 © Diversified Technical Systems, Inc. All Rights Reserved. Magnetic Pickup support.dtsweb.com 13006-90440-MAN (Rev. 3)
  • Page 45 SLICE6 AIR DAS User’s Manual July 2024 Revision History Date Description 31 Jan 2020 Initial release. 6 Feb 2020 Changed max input voltage from 36 to 30 VDC and updated consumption data. Replaced PPS with 1PPS. Added 50 kHz spec to fixed hardware filter.

Table of Contents