Vega VEGAPOINT 31 Operating Instructions Manual

Capacitive level switch, three-wire: io-link, transistor
Hide thumbs Also See for VEGAPOINT 31:

Advertisement

Quick Links

Operating Instructions
Capacitive level switch
VEGAPOINT 31
Three-wire: IO-Link, transistor
Document ID: 62325

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VEGAPOINT 31 and is the answer not in the manual?

Questions and answers

Summary of Contents for Vega VEGAPOINT 31

  • Page 1 Operating Instructions Capacitive level switch VEGAPOINT 31 Three-wire: IO-Link, transistor Document ID: 62325...
  • Page 2: Table Of Contents

    Sensor parameter adjustment ..................30 Setup with PC/notebook (Bluetooth) ................... 31 Preparations ........................31 Connecting ........................31 Sensor parameter adjustment ..................32 10 Diagnostics and servicing ....................33 10.1 Maintenance ........................33 10.2 Rectify faults ........................33 VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 3 13.1 Technical data ........................ 41 13.2 Device communication IO-Link ..................44 13.3 Dimensions ........................50 13.4 Industrial property rights ....................52 13.5 Licensing information for open source software ............. 52 13.6 Trademark ........................52 Editing status: 2024-07-22 VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 4: About This Document

    Symbols used Document ID This symbol on the front page of this instruction refers to the Docu- ment ID. By entering the Document ID on www.vega.com you will reach the document download. Information, note, tip: This symbol indicates helpful additional infor- mation and tips for successful work.
  • Page 5: For Your Safety

    During work on and with the device, the required personal protective equipment must always be worn. Appropriate use The VEGAPOINT 31 is a sensor for point level detection. You can find detailed information about the area of application in chapter "Product description". Operational reliability is ensured only if the instrument is properly used according to the specifications in the operating instructions manual as well as possible supplementary instructions.
  • Page 6: Safety Instructions For Ex Areas

    Safety instructions for Ex areas For applications in hazardous areas (Ex), only devices with corre- sponding Ex approval may be used. Observe the Ex-specific safety instructions. These are an integral part of the device documentation and are enclosed with every device with Ex approval. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 7: Product Description

    Information sheet "PINs and Codes" (with Bluetooth versions) with: – Bluetooth access code Information: Optional instrument features are also described in this instructions. The respective scope of delivery results from the order specification. Constituent parts The VEGAPOINT 31 consists of the components: • Housing with integrated electronics • Process fitting • Plug (optional) Fig.
  • Page 8: Principle Of Operation

    Open the VEGA Tools app and enter the serial number under "Documentation". Principle of operation Application area The VEGAPOINT 31 is a capacitive point level sensor for point level detection It is designed for industrial use in all areas of process technology and can be used in light-weight, fine bulk solids.
  • Page 9: Packaging, Transport And Storage

    Unless otherwise indicated, the packages must be stored only under the following conditions: • Not in the open • Dry and dust free • Not exposed to corrosive media VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 10: Accessories

    Various threaded and hygienic sockets are available for devices with socket threaded version. You can find further information in chapter "Technical Data". Protective cover For devices with dust Ex approval, the housing must be protected against external damage. Use the optional protective cover for this purpose. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 11: Mounting

    Chemical properties of the medium • Abrasion and mechanical influences Switching point The VEGAPOINT 31 can be mounted in any position. The instrument must be mounted in such a way that the sensor is at the height of the requested switching point. Fig. 3: Installation examples 1 Upper level detection (max.) as overflow protection...
  • Page 12: Mounting Instructions

    Mounting instructions Inflowing medium If VEGAPOINT 31 is mounted in the filling stream, unwanted false measurement signals can be generated. For this reason, mount VEGAPOINT 31 at a position in the vessel where no disturbances, e.g. from filling openings, agitators, etc., can occur. Vessel installations Metal vessel installation or struts can affect the switching sensitivity of the device.
  • Page 13 4 Mounting Fig. 4: Mounting of the protective cover Protective cover - 1. half Protective cover - 2. half Fixing screws (2 pieces) VEGAPOINT 31 VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 14: Connecting To Power Supply

    EN 61326-1 for industrial areas, shielded cable should be used. Connecting Instrument versions Fig. 5: Instrument versions Device version with housing 316L and plastic Device version with full metal housing 316L 360° status indication VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 15: Wiring Plan

    Contact, plug connector Function/Polarity Voltage supply/+ Transistor output 2 Voltage supply/- Transistor output 1/IO-Link Switch-on phase After switching on, the device first carries out a self-test in which the function of the electronics is checked. The current measured value is then output on the signal cable. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 16: Access Protection

    It can't be changed. The emergency device code can also be found on the supplied information sheet "Ac- cess protection". If this document is lost, the emergency device code can be retrieved from your personal contact person after legitimation. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 17: Storing The Codes In Myvega

    "PINs and Codes". This greatly simplifies the use of additional adjust- ment tools, as all Bluetooth access and device codes are automati- cally synchronized when connected to the "myVEGA" account VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 18: Setup

    NAMUR NE 107. Coverage 360° status indi- cation Switching status Switching status Output 1 Output 2 Covered open closed Green Uncovered closed open Yellow Fault open open (Covered/Uncov- ered) Default setting Switching status of output 1 VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 19: Menu Overview

    Function output (OU1) Opener (HNC) Function output 2 (OU2) Closing contact (HNO) Switching output Switching point (SP1) 85 % Switching delay (DS1) 0.5 s Reset point (RP1) 83 % Reset delay (DR1) 0.5 s Only for "User-defined" application VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 20: Parameter Adjustment

    This name is stored in the sensor and is used to identify the device. You can enter names with max. 19 characters. The character set comprises: • Upper and lower case letters from A … Z Only DTM adjustment VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 21 In addition there are the following status indications: • Simulation - red flashing • Maintenance required - green flashing Individual signalling If you have selected "Individual signaling", you can select the respec- tive LED colour separately for the following switching states. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 22 In this menu item you can set the function of the two outputs indepen- dently of each other. Closing contact = HNO (Hysterese Normally Open) - MIN (dry run protection) Opener = HNC (Hysterese Normally Closed) - MAX (overfill protec- tion) Closing contact = FNO (Window Normally Open) Opener = FNC (Window Normally Closed) VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 23 Window High (FH) and Window Low (FL). If the measured variable leaves the window, the output returns to its previous state. If the measured variable moves within the window, the state of the output does not change. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 24 The setting is a degree for the sensitivity of the sensor tip. Reset point (RP1) The reset point (RP) controls the sensitivity of the sensor when the sensor tip becomes free. The percentage defines the upper range limit of the hysteresis. The setting is a degree for the sensitivity of the sensor tip. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 25 After a reset, parameter adjustments made by the user are reset. The following reset functions are available: Restore basic settings: Resetting the parameter settings incl. spe- cial parameters to the default values of the respective device. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 26 In this menu item you can retrieve the current measured values of the device. Measured values Here you can view the current coverage status of the device (covered/ uncovered). Additional measured values Here you can find additional measured values of the device. • Electronic temperature (°C/°F) VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 27 Click on the button "Accept simulation value". The sensor now switches to the desired simulation switching status. During simulation, the LED display flashes in the colour of the se- lected switching status. A simulation of the fault status is not possible. To cancel the simulation, click on "Terminate simulation". VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 28 In this menu item you can retrieve the sensor features of the device. This menu item can only be selected via PACTware with DTM. • Order texts • Instrument version • Electronics • etc. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 29: Setup With Smartphone/Tablet (Bluetooth)

    • Operating system: Android 5.1 or newer • Bluetooth 4.0 LE or newer Download the VEGA Tools app from the "Apple App Store", "Goog- le Play Store" or "Baidu Store" to your smartphone or tablet. Connecting Connecting Start the adjustment app and select the function "Setup". The smart- phone/tablet searches automatically for Bluetooth-capable instru- ments in the area.
  • Page 30: Sensor Parameter Adjustment

    The sensor adjustment menu is divided into two halves: On the left you'll find the navigation section with the menus "Setup", "Diagnosis" and others. The selected menu item, recognisable by the colour change, is dis- played in the right half. Fig. 10: Example of an app view - Setup VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 31: Setup With Pc/Notebook (Bluetooth)

    Enter Bluetooth access For authentication, enter in the next menu window the 6-digit code Bluetooth access code: Fig. 11: Enter Bluetooth access code VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 32: Sensor Parameter Adjustment

    The sensor adjustment menu is divided into two halves: On the left you'll find the navigation section with the menus "Setup", "Display", "Diagnosis" and others. The selected menu item, recognisable by the colour change, is dis- played in the right half. Fig. 12: Example of a DTM view - Setup VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 33: Diagnostics And Servicing

    24 hour service hotline Should these measures not be successful, please call in urgent cases the VEGA service hotline under the phone no. +49 1805 858550. The hotline is also available outside normal working hours, seven days a week around the clock.
  • Page 34: Diagnosis, Fault Messages

    The switching point (SP) must be smaller than the reset point (RP) F260 Error in the calibration Repeat device adjustment F261 Error in the instrument settings Carry out device reset Reset device to delivery status VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 35: Status Messages According To Ne 107

    • Failure • Function check • Out of specification • Maintenance required and explained by pictographs: Fig. 13: Pictographs of the status messages Failure - red 2 Out of specification - yellow Function check - orange Maintenance required - blue VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 36 Carry out a reset values Error in the instrument set- tings Function check Code Cause Rectification Text message C700 A simulation is active Finish simulation Simulation active Wait for the automatic end after 60 mins. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 37: Software Update

    • The serial number of the instrument • A short description of the fault • Details of the medium, if applicable Print the generated instrument return form. Clean the instrument and pack it damage-proof. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 38 10 Diagnostics and servicing Send the printed instrument return form and possibly a safety data sheet together with the device. You will find the address for the return on the generated instrument return form. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 39: Dismount

    If personal data is stored on the old device to be disposed of, delete it before disposal. If you have no way to dispose of the old instrument properly, please contact us concerning return and disposal. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 40: Certificates And Approvals

    DIN EN ISO 14001. Help us to meet these requirements and observe the environmental instructions in the chapters "Packaging, transport and storage", "Dis- posal" of this instructions manual. VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 41: Supplement

    Other connections via hygiene adapters possible Max. torque - process fitting Ʋ Thread G½, ½ NPT 50 Nm (37 lbf ft) Ʋ Thread G¾, ¾ NPT 75 Nm (55 lbf ft) Ʋ Thread G1, 1 NPT 100 Nm (73 lbf ft) VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 42 Power supply on - Output 1 open Ʋ Yellow Power supply on - Output 1 closed Ʋ Red Voltage supply on - failure/simulation Adjustment Adjustment possibilities App (Android/OS), PACTware with DTM, I/O-Link via DTM, IODD or I/O-Link master VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 43 Output of the temperature values via Bluetooth, IO-Link Electromechanical data M12 x 1 plug connector Ʋ Cable Fixed connected to the plug Depending on the local conditions; with M12 x 1 plug stainless steel (closed full metal housing) effective range up to approx. 5 m (16.40 ft) Depending on the instrument version VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 44: Device Communication Io-Link

    VendorID 0x00, 0x62 9, 10, 11 DeviceID 0x00, 0x02, 0x00 512 Process data word Configuration 31 (MSB) … … 0 (LSB) Sensor X-value 0.1 % (frequency) Temperature in °C, resolution 0.1 K Out2 Out1 VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 45 0x03, 0x0E, 0x02, 0x03, 0x0E, 0x10 Vendor Name 0x0010 String VEGA Gries- haber KG Vendor Text 0x0011 String www.vega. Product Name 18 0x0012 String VEGAPOINT Product ID 0x0013 String VEGAPOINT Product Text 0x0014 String LevelSwitch VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 46 Switching delay (DS2) 0x010C Float Reset delay (DR2) 0x010D Float Switching point (FH2) 0x010E Float Reset point (FL2) 0x010F Float Switching delay (DS2) 0x0110 Float Detailed error information can be found Under Diagnosis, Error Messages VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 47 - failure 0x0120 0 … 255 Individual Signal- ling - switching output Green 0x0121 0 … 255 Individual Signal- ling - switching output Blue 0x0122 0 … 255 Individual Signal- ling - switching output VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 48 256 = Covered 512 = Covered in- side Window 768 = Covered outside Window Output 0x0134 Unsigned16 RO 0 = Open 1 = Closed Detailed error information can be found Under Diagnosis, Error Messages VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 49 ISDU (hex) Access Factory Reset 0x082 Reset Pointer - Resonance Frequency 0x0A1 Reset Pointer - Measuring Cell Temperature 0x0A3 Reset Pointer - Electronic Temperature 0x0A4 Uncovered 0x0A5 Covered 0x0A6 Accepting and activating taught-in settings 0x0AC VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 50: Dimensions

    (0.71") (0.71") Fig. 14: VEGAPOINT 31, standard version - thread with M12 x 1 plug Thread G½, G¾, G1 (DIN ISO 228/1) with M12 x 1 plug connection Thread G½, G¾, G1 (DIN ISO 228/1) with M12 x 1 plug connection - full metal version Thread ½...
  • Page 51 13 Supplement VEGAPOINT 31, protective cover ø 46 mm (1.81") Fig. 16: VEGAPOINT 31, protective cover VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 52: Industrial Property Rights

    Les lignes de produits VEGA sont globalement protégées par des droits de propriété intellec- tuelle. Pour plus d'informations, on pourra se référer au site www.vega.com. VEGA lineas de productos están protegidas por los derechos en el campo de la propiedad indus- trial. Para mayor información revise la pagina web www.vega.com.
  • Page 53 Notes VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 54 Notes VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 55 Notes VEGAPOINT 31 • Three-wire: IO-Link, transistor...
  • Page 56 Subject to change without prior notice © VEGA Grieshaber KG, Schiltach/Germany 2024 VEGA Grieshaber KG Am Hohenstein 113 Phone +49 7836 50-0 77761 Schiltach E-mail: info.de@vega.com...

Table of Contents