Adp PL Series Installation Instructions Manual

Premier indoor plenum coils

Advertisement

Available languages

Available languages

Quick Links

TABLE OF CONTENTS
General ............................................................5
Location and Clearance ..................................5
Plenum Coil Application...................................6
Suspended Coil Installation .............................6
Label Installation..............................................7
Metering Device...............................................7
Furnace Attachment ........................................8
Plenum Connections .......................................8
Secondary Drain Pan ......................................8
Condensate Drain............................................9
Coil Cleaning ...................................................9
Refrigerant Line Installation ...........................10
Refrigerant Charging .....................................10
Flammable Refrigerant Detection ..................10
SAFETY CONSIDERATIONS
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and signal word. These signals words mean the following:
DANGER: You can be killed or seriously injured if you don't immediately follow instructions.
WARNING: Indicate a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Caution may also be used to alert
against unsafe practices.
NOTICE: Indicates a statement of company policy as the message relates directly or indirectly to the safety of personnel or protection of property.
IMPORTANT: More detailed information concerning the statement of company policy as the message relates directly or indirectly to the safety of
personnel or protection of property.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or
lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications are subject to change without notice
and without obligation on our part. Please contact your ADP representative or distributor to verify details.
PL Series
Premier Indoor Plenum Coils
PAGE
CAUTION
© 2024 by Advanced Distributor Products. All rights reserved.
2175 West Park Place Blvd., Stone Mountain, GA 30087
www.adpnow.com
Installation Instructions
TABLE OF CONTENTS
Refrigerant Recovery .................................... 11
Maintenance and Repair ............................... 11
Warranty ........................................................ 12
Installation Check List ................................... 12
IM-PLC-0667392-08
March 2024
PAGE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PL Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Adp PL Series

  • Page 1 Product improvement is a continuous process at Advanced Distributor Products. Therefore, product specifications are subject to change without notice and without obligation on our part. Please contact your ADP representative or distributor to verify details. © 2024 by Advanced Distributor Products. All rights reserved.
  • Page 2 Evaporator Coil Safety CAUTION IMPORTANT Any service personnel installing, decommissioning, or per- This unit is a PARTIAL UNIT AIR CONDITIONER, complying forming maintenance on the unit must be properly trained with with PARTIAL UNIT requirements of this Standard, and must only be connected to other units that have been confirmed as A2L refrigerants complying to corresponding PARTIAL UNIT requirements of...
  • Page 3 Evaporator Coil Safety IMPORTANT IMPORTANT Work shall be undertaken under a controlled procedure so as Where electrical components are being changed, they shall be to minimize the risk of a flammable gas or vapor being present fit for the purpose and to the correct specification. At all times while the work is being performed.
  • Page 4 Evaporator Coil Safety WARNING NOTICE Auxiliary devices which may be a potential ignition source shall All maintenance staff and others working in the local area shall not be installed in the duct work. Examples of such potential be instructed on the nature of work being carried out with work ignition sources are hot surfaces with a temperature exceeding in confined spaces being avoided.
  • Page 5 GENERAL ADP evaporator coils are designed for use with condensing units or heat pump units. These instructions are intended as a general guide and do not supersede local codes in any way. Consult with local authorities having jurisdiction before installation.
  • Page 6 PLENUM COIL Drain Pans IMPORTANT  Drain pans are made of a polymer that can withstand temperatures up to 450°F. For proper operation, after brazing, attach and insulate the TXV sensor bulb at a 10 to 2 o’clock position to the ...
  • Page 7 LABEL INSTALLATION Permanently mark the serial label with the appropriate A1 (R-410A & R-22)refrigerant & metering device used. See example below. For A2L (R-454B & R-32) installations refer to the ADP’s Refrigerant Detection System Kit for instructions. METERING DEVICE Coils are suited for R-22, R-410A and can be configured for R- 454B, R-32 with Refrigerant Detection System kit.
  • Page 8 FURNACE ATTACHMENT Align the bottom edges of the coil and furnace—the included FIGURE 3 furnace mount bracket (Figure 3) may be attached to the coil with 2 screws. Attach coil to furnace flanges using sheet metal Furnace Attachment screws. Seal according to local codes. Coil Support Options 1.
  • Page 9 CONDENSATE DRAIN FIGURE 5 Coils are equipped with multiple drain connections. Determine Drain Trap and Vent Tee the drain connections to be used and note the difference between the primary (green) and secondary (red) openings. Drain plugs are provided for all openings; remove and discard the appropriate plugs with ½"...
  • Page 10 REFRIGERANT LINE INSTALLATION If installing the coil in a system using A2L refrigerants. DO NOT BRAZE ANY LINE SETS without reviewing ADP’s Refrigerant Detection System Kit Installation manual for specific requirements on primary and secondary joints within the installed spaces.
  • Page 11 REFRIGERANT RECOVERY Before carrying out work on systems containing refrigerant, it is essential that the technician is completely familiar with the equip- ment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Prior to the task being carried out, an oil and refrigerant sample shall be taken in case analysis is required prior to re-use of recovered refrigerant.
  • Page 12 ADP LIMITED WARRANTY Term of Warranty  Equipment Information Advanced Distributor Products (ADP) warrants that products Please complete information below and retain this warranty for sold shall be of merchantable quality, free of defects in records and future reference. material and workmanship, under normal use and service, for...
  • Page 13: Table Of Contents

    L’amélioration des produits est un processus continu chez Advanced Distributor Products. Par conséquent, les spécifications des produits sont sujettes à modification sans préavis et sans obligation de notre part. Veuillez contacter votre représentant ou distributeur ADP pour vérifier les détails.
  • Page 14 Sécurité relative à l’évaporateur AVIS ATTENTION Cette unité, est un CLIMATISEUR PARTIEL, conforme aux Tout le personnel qui installe, retire du service ou entretient exigences DES UNITÉS PARTIELLES de la présente norme; l'unité doit être correctement formé aux réfrigérants A2L. elle ne doit être raccordée qu'à...
  • Page 15 Sécurité relative à l’évaporateur IMPORTANT IMPORTANT Les travaux doivent être entrepris selon une procédure con- Lorsque des composants électriques sont remplacés, ils doi- trôlée afin de minimiser le risque de présence d'un gaz ou vent être adaptés à l'usage prévu et conformes aux spécifica- d'une vapeur inflammable pendant l'exécution des travaux.
  • Page 16 Sécurité relative à l’évaporateur AVERTISSEMENT AVIS Aucun dispositif auxiliaire pouvant être une source Tout le personnel de maintenance et les autres personnes d'inflammation potentielle ne doit pas être installé dans les travaillant dans la zone doivent être informés de la nature des conduits.
  • Page 17: Généralités

    GÉNÉRALITÉS Les serpentins d'évaporateur ADP sont conçus pour être utilisés avec des climatiseurs ou des thermopompes. Ces instructions contiennent des directives générales, mais n’ont aucunement vocation à supplanter les codes locaux. Consultez les organismes locaux compétents avant l’installation. Lisez ce manuel d'installation et tous les « Avertissements » avant d'installer le serpentin d'évaporateur.
  • Page 18: Serpentin Avec Plénum

    SERPENTIN AVEC PLÉNUM Bacs de drainage IMPORTANT  Les bacs de drainage en polymère peuvent résister à des températures de 450 °F. Pour un rendement optimal, installez et isolez le bulbe de la TXV dans une position comprise entre 10 et 2 heures ...
  • Page 19: Dispositif De Mesure

    Marquez de manière permanente l'étiquette de série avec le réfrigérant A1 approprié et le dispositif de mesure utilisé. Voir l'ex- emple ci-dessous. Pour les installations A2L, référez-vous au manuel du kit de système de détection de réfrigérant d'ADP pour les instructions.
  • Page 20: Fixation Au Générateur D'air Chaud

    FIXATION AU GÉNÉRATEUR D’AIR CHAUD Alignez les bords inférieurs du serpentin et du générateur. Le FIGURE 3 support de montage du générateur inclus (Figure 3) peut être fixé au serpentin avec 2 vis. Fixez le serpentin aux brides du Fixation au générateur d’air chaud générateur avec des vis à...
  • Page 21: Drain De Condensat

    DRAIN DE CONDENSAT FIGURE 5 Les serpentins sont équipés de plusieurs raccords de Piège de drainage et T d’évent drainage. Déterminez les raccords à utiliser et notez la différence entre les orifices primaires (verts) et secondaires (rouges). Des bouchons de drainage sont fournis pour toutes L’évent doit dépasser d’au les ouvertures.
  • Page 22: Installation Des Conduites De Réfrigérant

    Si vous installez la bobine dans un système utilisant des réfrigérants A2L, NE SOUDEZ AUCUN DES ENSEMBLES DE TUYAUX sans avoir préalablement examiné le manuel d'installation du kit de système de détection de réfrigérant d'ADP pour connaître les exigences spécifiques concernant les joints primaires et secondaires dans les espaces in- stallés.
  • Page 23: Détection De Réfrigérant Inflammable

    DÉTECTION DU RÉFRIGÉRANT INFLAMMABLE le pourcentage approprié de gaz (25 % maximum) est Ne jamais utiliser une source d'inflammation potentielle pour confirmé. rechercher ou détecter les fuites de réfrigérant.  Des liquides de détection de fuites peuvent également être Ne pas utiliser de lampe haloïde (ou tout autre détecteur utilisés avec la plupart des réfrigérants, mais ne pas utiliser utilisant une flamme nue).
  • Page 24: Entretien Et Réparation

    ENTRETIEN ET RÉPARATIONS INSTRUCTIONS Lorsqu’il est nécessaire d’ouvrir le circuit de réfrigérant pour effectuer des réparations – ou à toute autre fin – les procédures conventionnelles doivent être utilisées. Cependant, pour les réfrigérants inflammables, il est important de suivre de bonnes pratiques de travail comme le retrait en toute sécurité...
  • Page 25: Garantie

    GARANTIE LIMITÉE D’ADP Période de garantie Information sur l’équipement Advanced Distributor Products (ADP) garantit que les produits Écrivez renseignements demandés ci-dessous vendus sont de qualité marchande et exempts de défauts de conservez la présente garantie dans vos dossiers pour matière et de fabrication, dans des conditions d’utilisation et consultation future.
  • Page 26 2175 West Park Place Boulevard Stone Mountain, GA 30087 www.adpnow.com...

Table of Contents