WALL MOUNT INSTALLATION INSTRUCTIONS
G
ENERAL
These instructions are intended as a general guide and do
not supersede local codes in any way. Consult with
authorities having jurisdiction before installation.
ADP "W" series air handlers are suitable for closet or flush
mount installations and are designed for electrical heat
installation with a matched remote outdoor unit. These units
are designed for indoor installations only.
IMPORTANT
The Clean Air Act of 1990 bans the intentional
venting of refrigerant (CFC's and HFC's) as of
July1, 1992. Approved methods of reclaiming must
be followed. Fines and/or incarceration may be
levied for non-compliance.
The following words are used throughout this manual to
identify levels of hazard seriousness.
DANGER-Immediate hazards that WILL result in severe
personal injury or death.
WARNING-Hazards or unsafe practices COULD result in
severe personal injury or death.
CAUTION-Hazards or unsafe practices COULD result in
minor personal injury or product or property damage.
W SERIES AIR HANDLER
WARNING!
Product contains fiberglass wool.
Disturbing the insulation in this product during
installation, maintenance or repair will expose you
to fiberglass wool. This material may cause
respiratory, skin, and eye irritant. Breathing this
may cause lung cancer. (Fiberglass wool is known
to the State of California to cause cancer.)
R
ECEIVING
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
Check the unit rating plate for unit size, electric heat, coil,
voltage, phase etc. to be sure unit matches requirements.
R
EQUIREMENTS
Installation of air handler units with or without optional
electric heat must conform with standards in the National
Fire
Protection
Association
installation of Air Conditioning and Ventilation Systems
NFPA No. 90A," and Standard for Installation of Residence
Type warm Air Heating and Air Conditioning Systems NFPA
No. 90B, manufacturer's installation instructions and local
municipal building codes.
This unit is certified for installation clearances to
combustible material as listed on the unit rating plate.
Accessibility and service clearances must take precedence
over combustible material clearances.
Part # 065463808
October 2009
(NFPA)
"Standard
for
T
C
ABLE OF
ONTENTS

Advertisement

loading
Need help?

Need help?

Do you have a question about the W Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Adp W Series

  • Page 1: Table Of Contents

    Air Conditioning and Ventilation Systems ADP “W” series air handlers are suitable for closet or flush NFPA No. 90A,” and Standard for Installation of Residence mount installations and are designed for electrical heat Type warm Air Heating and Air Conditioning Systems NFPA installation with a matched remote outdoor unit.
  • Page 2 NSTALLATION W Series air handlers are suitable for free-air return as enclosed in a closet with a louvered door, flush mounted in a wall, or typical upflow application with bottom return air duct. Closet or “ON” the wall applications Note: If mounted in a closet a louver or grill with at least 1 square foot of face area per ton is required on the door.
  • Page 3: Condensate Drain

    Remove the existing piston from inside the distributor assembly Superheat (°F) Outdoor Air Insert the desired ADP piston into the distributor Temp. (°F) assembly. Inspect “O” ring and replace if damaged. Ensure gasket is in place.
  • Page 4 Route drain line so that it does not interfere with accessibility to the coil, air handling system or filter and will not be exposed to freezing temperatures. If line makes a second trap, or has an extended run before termination, a vent tee should be installed after the trap closest to the pan.
  • Page 5: Wiring Low Voltage Connections

    If the air handler is purchased and installed with a heat kit and needs to be converted in the field back to no heat a “no Cooling Only Application heat reversion package" is required for operation. See ADP’s Air Handler Accessories Sheet for further details. Thermostat Air Handler LOWER...
  • Page 6: Physical Data, Nomenclature

    HYSICAL Model Available Voltages 208/240 V, 60 Hz, 1 Phase Maximum Elec. Heat available (kW) Transformer Size and Type 40VA, Class 2 Wheel (dia.” X width”) 10 x 6 10 x 6 10 x 6 10 X 8 10 x 8 10 x 8 Motor H.P.
  • Page 7 Model Nomenclature W = Wall Mount Panel Options A = Includes upper front panel (embossed) B = Includes upper and lower front panel (embossed) C = Includes upper front panel (beige) D = Includes upper and lower front panel (beige) L= Includes upper and lower louvered front panel (beige) Coil Slab Number...
  • Page 8 Performance Cooling Wet DX Coil with Filter & Electric Heat CFM vs. ESP (inches H Model Speed Setting W****18 Medium High W****24 Medium High W****30 Medium 1,009 High 1,129 1,085 1,047 1,111 1,076 1,040 W****31 Medium 1,242 1,189 1,151 1,089 1,016 High 1,335...
  • Page 9: Electrical Wiring Diagram

    LECTRICAL IRING IAGRAM...
  • Page 10: Dimensions

    Dimensions Unit Size Duct Opening 18, 24, 30 15.0" 38 1/2" 11.0" 7.0" 5 1/2" 2 1/4" 3 1/4" 10.0" D X 14.0" W 31, 36, 42 18 3/4" 44 1/2" 14 1/2" 7 3/8" 6.0" 2 1/2" 5 1/2" 12.0" D X 14.0" W 3/4"...
  • Page 11 It is expressly understood and agreed that ADP shall not be liable to buyer, or any customer of buyer, for direct or indirect, special, incidental, consequential or penal damages, or for any expenses incurred by reason of the use or misuse by buyer or third parties of said products.

This manual is also suitable for:

W 18W 24W 30W 31W 36W 42