VNX5700 rear view
Table 10 Control Station LEDs
LED
System status/boot
(location 2)
System power/sleep or
standby (location 3)
Internal hard drive activity
(location 4)
Onboard (integrated)
Ethernet NIC 1 and 2
(locations 5 and 6,
respectively)
1. The system status LED flashes green while booting up.
On the rear, viewing from top to bottom, a Block and File (Unified) VNX5700 platform
includes the following hardware components:
One to two Control Stations
◆
One Data Mover enclosure with two, three, or four Data Movers
◆
One SPE with two storage processors (SPs), each SP (A and B) having one CPU module
◆
and one power supply module
One dual 1U SPS or one dual 2U SPS
◆
Color
State
Green
On
Blinking
Amber
On
Blinking
—
Off
Green
On
Blinking
—
Off
Green
Blinking
—
Off
Green
On
Blinking
VNX5700 Hardware Information Guide
System component description
Description
Power on/system loaded and
ready
1
Booting up
or system degraded
Critical, non-recoverable error;
system has failed due to:
• Themtrip asserted
• IERR asserted
• Non-recoverable temperature
threshold asserted.
• Non-recoverable voltage
asserted.
• Power fault/Power control
failure
Non-fatal alarm; system is likely
to fail due to:
• Critical temperature threshold
asserted.
• Critical voltage threshold
asserted.
• Critical fan threshold
asserted.
Power off
Power on
Sleep (standby)
Power off
Hard drive access
No hard drive activity
NIC link/no access
NIC link/LAN access
25
Need help?
Do you have a question about the VNX5700 and is the answer not in the manual?