MODEL PART DIAGRAM
FRONT
Control Panel
Front Panel
PACKAGE CONTENTS
(1) Pre-Filter
Unit
(8) Activated Carbon Filters
(2) True HEPA Filters
WHERE TO USE
12~18 in
12~18 in
4-STAGE AIR PURIFICATION
Pre-Filter
Activated Carbon Filter
1
2
Winix Smart Wi-Fi Setup
Before you begin, make sure you have a wireless router
that is 2.4Ghz or newer and have a Smartphone that is
Android 5.0 and later or iOS 10.0 and later. Reference the
Winix Smart Wi-Fi Set Up Guide for more details.
• Latest Phone Operating System requirements are
subject to change based on future phone technology
and app version updates.
• Make sure to disable any VPN networks before
connecting your unit.
1.
Download the Winix Smart app on your device.
• available via Google Play store or iTunes App
store.
2.
Run the app and follow the setup guide to connect
your device to the unit.
INITIAL OPERATION
1. Remove the front panel by grasping its
upper edge and gently pulling forward.
2. Remove the Pre-Filter, then the bag of
filters behind it.
3. After removing the packing vinyl of the
filter, insert the Activated Carbon Filter
into the Pre-Filter.
4. Install the filters until they fit securely in place.
02. True HEPA Filter (back)
01. Pre-Filter (With Carbon Filter) (front)
5. After filters are installed, close the front
panel.
6. Insert the power cord into an electrical
outlet.
MAINTENANCE
When to Replace Filters
Filter
Indicator Light
Pre-Filter
none
Activated Carbon
none
Filter
True HEPA Filter
• When the Check Filter Indicator LED is flickering, it is time to replace the Filter.
• Intervals between filter replacement may vary depending on environment.
C909_User(2610-0321-00)_V1_EN.indd 1
C909_User(2610-0321-00)_V1_EN.indd 1
BACK
Handle
Air Outlet
Vent
Power Plug
User
Alexa Setup Guide /
Manual
Wi-Fi Setup Guide
Allow 12 ~ 18 in. of space between TVs, radios, and
other electronics
Electromagnetic interference from certain electronics
may cause product malfunction.
Place indoors away from direct sunlight
Direct exposure may cause product malfunction or
failure.
Only place on hard, flat surfaces
Flimsy or slanted surfaces may result in abnormal
noise and vibrations.
Allow at least 12 ~ 18 in. from walls for maximum air
flow
Air Purification means it
removes inanimate particles
PlasmaWave
True HEPA Filter
3
4
Technology
Select "New Unit" and choose C909 to connect
①
to this model.
Read the notice and select "OK".
②
Enter the password to your Wi-Fi network.
③
Press and hold the Wi-Fi button on the unit's
④
control panel until it beeps.
• The Wi-Fi strength indicator will begin to
blink.
Connect to the Winix Smart network via your
⑤
device's network menu.
Selecting "Next" will connect your unit to your
⑥
device.
Define the unit settings (Name and Location).
⑦
When set up is complete, the Winix Smart
⑧
Indicator will light up.
Latch
02
01
Latch
When to Ser vice
When to Replace
Clean once every
Permanent
14 days
Replace every
3 months
Can NOT be WASHED
Lasts Approx.
12 months
CONTROL PANEL
01
02
03
07
08
09
10
01. Air Quality Indicator
Color coded LED light indicates one of three levels
of Air Quality: Red (poor), Amber (fair), and Blue
(good).
02. Auto Mode Indicator
The LED "Auto" light will indicate when Auto Mode
is activated.
03. Fan Speed Indicator
Indicates the current fan speed.
Low Medium High
Turbo
04. Sleep Mode Indicator
The LED "Sleep" light will indicate when Sleep
Mode is activated.
05. Filter Replacement Indicator/
Filter Reset Button
• Indicator : LED light indicates when it is time to
change the filter.
• Button : After replacing the True HEPA Filter,
press the Filter Reset button for at least 5
seconds until the Filter Replacement Indicator
turns off.
06. Wi-Fi Indicator
• Enables or disables the Wi-Fi feature.
• When in the pairing state, the Wi-Fi LED
flashes.
• When paired successfully, the Wi-Fi LED will be
a solid white light.
07. Smart Sensor
Detects the amount of odorous gas in the
environment. When in Auto mode, the fan speed
®
adjusts according to the detected amount of gas.
08. Power Button
Turns the unit on or off. During the first 30 seconds
REPLACING FILTERS
Resetting Filter Life:
After replacing your True HEPA Filter, place the Pre-Filter back in and close the Front
Panel. While the unit is on, hold the Filter Reset Button for at least 5 seconds until
you hear the beep. After the beep, the Filter Replacement Indicator will disappear.
Your Winix True HEPA is now reset.
CLEANING CARE
Cleaning the Filters:
Use a vacuum cleaner or soft brush to clean the
Pre-Filter
• If it is excessively soiled, rinse in room
temperature water.
• Do not use detergent or soap.
• Allow the filter to dry for 24 hours or more
before using.
• Intervals between filter cleaning may vary
depending on the air quality.
• Do not use hot water over 104
o
F or volatile
fluids such as paint thinner.
N O T I C E
• When cleaning the unit, always unplug the
power cord first and then wait until the unit has
cooled down.
• Never disassemble, repair, or modify the unit
yourself.
• Do not use flammable sprays or liquid detergents.
• Do not allow children to clean or maintain the unit.
• Before cleaning or maintaining, ensure unit is
unplugged.
• Do not use benzene, alcohol, or other
volatile fluids, which may cause damage or
discoloration.
of powering up, the Air Quality Indicator will cycle
through Blue, Amber and Red colors.
04
05
06
• Odor Sensor takes approximately 4 minutes to
detect the air quality in the environment before
normal operation begins.
09-1. Fan Speed/Auto/Sleep Buttons
Use the Fan Speed arrow buttons to set the
desired fan speed. Fan Speeds cycle over in
11 12
this sequence: Auto, Low, Medium, High, Turbo,
Sleep, Auto.
• Auto Mode:
- Auto Mode automatically adjusts fan
speeds according to your indoor air
quality. The fan speed will adjust to low
when air quality is good, medium when
fair, and to high when poor.
• Sleep Mode:
When Sleep Mode is activated, the Air Quality
Indicator LED light is disabled.
- Fan speed will automatically set to
minimum speed (lower than 'Low') which
will be nearly silent.
- When Sleep Mode is active, PlasmaWave
will be disabled, but it can be turned back
on.
09-2. PlasmaWave
®
Button Press and hold the two arrow
buttons
+
for 3 seconds
®
Press the Plasmawave
button when the unit is
on to enable or disable this feature. By default,
®
PlasmaWave
is enabled whenever the unit is
powered on. When the unit is running, you may
hear a chirping or buzzing sound. The sound is
from particles passing through PlasmaWave
is normal and does not signify product failure.
®
10. PlasmaWave
Indicator
Indicates whether PlasmaWave
disabled.
11. Wi-Fi Button
• Press for 3 seconds to activate pairing mode.
• When Wi-Fi is paired, press the button to turn
Wi-Fi off or back on.
12. Light Sensor
Detects the amount of ambient light in the
environment. When in Auto Mode, the light sensor
detects when to put the unit into Sleep Mode.
115115
Cleaning the Exterior & Interior:
Wipe with a soft damp cloth using room
temperature water.
• Afterwards, wipe it down with a clean, dry cloth.
Open the front panel and clean the interior with a
vacuum cleaner.
• For optimal performance, clean every 1 - 2 months.
SPECIFICATIONS
Model
Voltage
AC 120 V / 60 Hz
Power Rate
Verified
500 sq.ft.
Room Size
16.5 in(W) × 11.4 in(D)
Dimensions
× 23.2 in(H)
Weight
17.2 lbs
Replacement
Filter A / SKU: 115115
Filter
The exterior, design, and product specifications
may be changed without prior notice to improve
product performance.
2023-05-21 오후 4:15:02
2023-05-21 오후 4:15:02
®
®
, it
®
is enabled or
C909
95 W
Need help?
Do you have a question about the C909 and is the answer not in the manual?
Questions and answers
What is the difference between the blue A label and the yellow A label for item 115115, model C909?