Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear eye
instruction
protection
manual
1. SAFETY
IMPORTANT These instructions are provided as a guide only. Always refer to the manufacturer's service instructions.
Keep this product in good working order and condition, take immediate action to repair or replace damaged parts.
9
Use approved parts only. Unapproved parts will invalidate the warranty.
9
Keep children and unauthorised persons away from the work area.
9
Keep work area clean and tidy and free from unrelated materials.
9
Ensure the work area has adequate lighting.
9
DO NOT use the kit to perform a task for which it is not designed.
8
DO NOT hold pump inlet against the skin whilst using the pump.
8
DO NOT allow untrained persons to use the kit.
8
DO NOT use whilst under the influence of drugs, alcohol or intoxicating medication.
8
After use, clean equipment and store in a cool, dry, childproof area.
9
WARNING! Brake fluid will damage paintwork. Any spillage should be flushed with water immediately.
WARNING! Brake fluid is flammable - keep away from sources of ignition,including hot surfaces e.g. exhaust manifold.
Dispose of waste liquids in accordance with local authority regulations.
9
WARNING! DO NOT pollute the environment by allowing uncontrolled discharge of fluids.
Always read and comply with the warnings on the brake fluid container.
9
Wear eye protection and keep skin contact to a minimum. If brake fluid enters eyes rinse with plenty of water and seek medical
9
advice. If swallowed seek medical advice immediately.
2. INTRODUCTION
Professional vacuum/pressure diagnostic tool helps identify a variety of faults on vehicle systems including fuel, ignition, transmission,
emission and air conditioning/heating. Kit also includes reservoirs, hoses and adaptors for bleeding brake and clutch systems.
Features lightweight aluminium body with simple twist function for choice of pressure or vacuum testing. Large rubber easy-to-read
gauge. Supplied in carry-case.
3. CONTENTS
(1).Vacuum Pump, (2) . Fluid Container (x2), (3). Transfer Cap, (4).
Vacuum Hoses; (5). 6mm (x1), (6). 8mm (x2), 6mm (x2), (7) Assorted
Connectors & Blanking Caps (x19)
© Jack Sealey Limited
VACUUM & PRESSURE TEST/BLEED KIT
MODEL NO:
Wear protective
gloves
fig.1
Original Language Version
VS403.V3
VS403.V3
Issue: 4 (H,F) 17/05/23

Advertisement

loading

Summary of Contents for Sealey VS403.V3

  • Page 1 VS403.V3 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Operation

    The VS403.V3 can be used for both pressure and vacuum testing by means of the sliding sleeve selector at the front end of the pump. To select PRESSURE TESTING mode, move the sliding sleeve away from the nozzle end of the pump until it makes contact with the main body.
  • Page 3 FUEL SYSTEMS: TESTING MECHANICAL FUEL PUMPS The VS403.V3 vacuum tester can be used to evaluate the condition of a mechanical fuel pump by testing the vacuum that it is able to create. Locate and remove the suction line from the pump. Connect the VS403.V3 vacuum tester to the suction port of the pump, start and run the engine at idle.
  • Page 4 Start engine and run at idle until normal operating temperature is reached. Remove the vacuum line from the EGR valve and attach the VS403.V3 vacuum tester kit (fig.8). Operate the hand pump to apply approximately 15 inHg of vacuum. If the EGR Valve is working correctly the engine idle will become rough.
  • Page 5 VS403.V3 is extremely simple. Locate the solenoid to be tested and remove the line that goes to the component being tested. Connect the VS403.V3 to the solenoid port (fig.10) and start the engine.
  • Page 6 Automatic transmissions are normally equipped with a vacuum operated modulator valve in order for the automatic transmission to detect engine loads and adjust shift points to suit. The VS403.V3 vacuum tester can be used to test both that the modulation valve diaphragm is serviceable and also to simulate varying engine loads so modulator pressure readings can be recorded.
  • Page 7: Environment Protection

    Refer to the relevant vehicle manufacturer’s instructions for clutch bleeding procedure. If no specific instructions from the vehicle manufacturer exist, follow the same basic procedure as the brake bleeding instructions above. Parts support is available for this product. Please email sales@sealey.co.uk or telephone 01284 757500 ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste.