Repeat Mechanism; Removal And Reassembly Procedure; Reassembly Of Cabinet - JVC QL-F300 Service Manual

Quartz locked fully-automatic turntable
Table of Contents

Advertisement

2-(4)
Repeat Mechanism
When the REPEAT knob is turned ON, the slider is placed in
the position (where the slider contacts the stopper at part
'""A'') shown in Fig. 11 and the mechanism operates to lead
in the tonearm
repeatedly
to the same
position.
As the
repeat
rod moves
in direction
''a'', the slider moves
in
direction ''b'' and stays there.
Repeat Rod
lf the change cycle starts in this state, the lead-in lever
turns in direction ''c'' and moves with arm lever stud
As the drive plate moves,
the tonearm
will be driven
in
direction ''d'' to perform the lead-in operation.
Slider
Fig. 11
3. Removal and Reassembly Procedure
3-(1)
Removel of Cabinet
1. Remove feet @) ~
(4) shown in Fig. 12.
2. Remove
the cord
stopper
of the signal cord as
shown in Fig.12.
3. Remove
the
head
shell
and
main
weight
from
the
tonearm.
4. Move the tonearm in direction of the center spindle as
shown in Fig.13.
5. Life the cabinet up, then remove the cabinet.
Note:
When the cabinet touches the tonearm, this may
damage the tonearm and the cabinet.
3-(2)
Reassembly of Cabinet
1. Set the operation switches on the front as follows:
Operation switch
|
Setting
|
f
SIZE
30
|
REPEAT
OFF
CUEING
DOWN
2. Set the tonearm as in Fig. 13.
3. Reassemble the cabinet.
Note:
When remouting the feet Q) - (), mount the
feet having slipproof at the front side.
QL-F300
No. 2650
®
@
Fig. 12
Fig. 13

Advertisement

Table of Contents
loading