Sharp XL-DK257N Service Manual page 80

Table of Contents

Advertisement

XL-DK257N
IC701 RH-IXA159AW00: System Microcomputer (1/5)
NAME
Pin
No.
PORT_TYPE
NO USE
1
P96/ANEX1
NO USE
2
P95/ANEX0
3
VOL_DATA
P94
4
VOL_CLK
P93
5
NO USE
P92/TB2IN
6
NO USE
P91/TB1IN
7
VOL_LATCH
P90/TB0IN
8
BYTE
BYTE
9
CNVSS
CNVSS
10
XCIN
P87/XCIN
11
XCOUT
P86/XCOUT
12
RESET
RESET
13
X_OUT
XOUT
14
GND
VSS
15
X_IN
XIN
16
VCC
VCC1
17
NMI
P85/NMI
18
P-IN
P84/INT2
19
OSC
P83/INT1
20
RX_IN
P82/INT0
21
AMP DET
P81
22
AMP MUTE
P80
23
AMP ON/OFF
P77
24
RDS_VOLT_CONT
P76
25
RDS DATA
P75/TA2IN
INPUT /
FORM
OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
INPUT
INPUT
INPUT
INPUT
INPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
INPUT
INPUT
OUTPUT
CMOS OUTPUT
-
-
INPUT
CMOS INPUT
-
-
INPUT
CMOS INPUT
INPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
INPUT
CMOS INPUT / OUTPUT
INPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
OUTPUT
CMOS INPUT / OUTPUT
INPUT
CMOS INPUT / OUTPUT
8 – 7
SOFT
FUNCTION OUTLINE
PULLUP
Fix "L"
OFF
Fix "L"
COMMUNICATION WITH
DATA OUTPUT
COMMUNICATION WITH
CLOCK OUTPUT
Fix "L"
OFF
Fix "L"
COMMUNICATION WITH
LATCH OUTPUT
EXTERNAL BUS. JOINT TO
-
VSS IF NO USE
USED IN SINGLE MODE.
CONNECT TO VSS
THROUGH PULL DOWN
-
RESISTOR. EXCLUSIVE USE
FOR VCC DURING FLASH
WRITING
32.768kHz X'tal (SUB-CLOCK)
OFF
32.768kHz X'tal (SUB-CLOCK)
RESET INPUT. ACTIVE "L"
-
CONNECT TO WRITER
RESET LINE DURING FLASH
MICOM STANDARD
OSCILLATION OUTPUT
-
CONNECT TO 9.8MHz
CERAMIC OSCILLATION
-
CONNECT TO GND(VSS).
MICOM STANDARD
OSCILLATION OUTPUT
-
CONNECT TO 9.8MHz
CERAMIC OSCILLATION
SUPPLY INPUT TO MICOM
-
(3.3V)
BACK-UP POWER SUPPLY
CONNECT TO VCC
-
THROUGH PULL UP RESIS-
TOR. (SET FOR FLASH)
POWER FALURE DETEC-
TION. JUDGE AS POWER
OFF
FAILURE IF FAIL TO DETECT
EDGE WITHIN 90 msec.
OSCILLATOR FREQUENCY
ADJUSTMENT. SET FOR
H=415kHz, L=375kHz
REMOCON IN
(SHARP FORMAT)
OFF
POWER IC ABNORMAL
DETECT ABNORMAL=L
AMP MUTE CONTROL L:
MUTE OFF, H: MUTE ON
AMP ON/OFF CONTROL L:
OPERATING MODE,
H: STANDBY MODE
RDS FUNCTION CONTROL H:
OFF
FM FUNC ONLY (H MODEL)
RDS DATA in (H MODEL)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp-dk257n