[2] Test Mode

• Setting the test mode
During AC unplug, plug-in AC while pressing down the
POWER button and CD button. Then, press the CD
button to enter the test mode.
Step
Step
Step
Step
Step
C D
OPEN/CLOSE operation is using manual.
1
2
3
4
5
Reading Sub-code and Display
STOP and return to Step 1
Hold down << CD >> key for more than 2 sec.
Start Auto Adjustment at current pick-up location.
T E S T
/
<<
>> key input.
Laser ON.
/
<<
>> key input.
Focus ON
/
<<
>> key input.
CLV Servo ON
<<
/
>> key input.
Tracking Servo ON
<<
/
>> key input.
<<STOP>> key input.
<<STOP>> key input.
2 – 2
IL isn't done