6.3 Settings for Upper and Lower Output Clipping
Configuration
Name
Upper limit of upper and lower
output clipping
Lower limit of upper and lower
output clipping
Sample program
Example) CH0 shows control examples for cases exceeding the upper and lower limits.
R0
(
DF
)
R1
(
DF
)
X101
Upper limit
relay
X102
Lower limit
relay
● Upper and lower limit settings are used to clip the output according to the resolution of the
original output range regardless of whether scale conversion is set or not.
6-6
Default
Setting range and description
K0
Set the upper limit to turn ON the upper limit relay for the use of
the function of clipping upper and lower output limits.
Setting range: -32,500 to +32,500 (Specified with a signed
integer)
K0
Set the lower limit to turn ON the lower limit relay for the use of the
function of clipping upper and lower output limits.
Setting range: -32,500 to +32,500 (Specified with a signed
integer)
Y110
(CH0)
<
SET
>
Turn ON the execution
Upper and lower
relay.
limit execution
relay
Y110
(CH0)
<
RST
>
Turn OFF the
Upper and lower
execution relay.
limit execution
relay
Y200
(CH0)
Turn ON Y200 when
the value exceeds the
upper limit.
(CH0)
Y201
Turn ON Y201 when
the value drops below
the lower limit.