NEC LED-FE012i3 Installation And Maintenance Manual page 34

Hide thumbs Also See for LED-FE012i3:
Table of Contents

Advertisement

(3) Connection when using a wall-mount frame
This connection is an example of connection when using the maximum capacity.
The power cable corresponding to the yellow part needs to be prepared by the customer.
Please connect considering the capacity of the switchboard and the inrush current specification.
4 x 4 frame set
AC POWER
HDMI
Controller
(MCTRL660Pro)
DVI
4 x 4 frame set
Number of power system
Current rating
Inrush current
25°C Cold start
Pulse width: 3ms
per 1 module
per power system
per frame set
per 1 module
per power system
per frame set
AC 100V
2
0.5 A
4.0 A
8.0 A
50 A
400 A
800 A
English - 32
AC 200V
2
0.3 A
2.4 A
4.8 A
100 A
800 A
1600 A

Advertisement