NEC MultiSync 3D JC-1404HME Service Manual page 24

Table of Contents

Advertisement

(6) Focus Adjustment
a) Receive signal 12 (all white"%" or 4-dots missing signal)
Contrast control
: Fully clockwise
Brightness control : At a point where no back raster appears
b) Turn the focus control and adjust for the optimum focus.
(7) Purity Adjustment
a) Be sure that the display_ is not being exposed to any external magnetic fields.
b) Ensure that the spacing between the Purity, Convergence Magnet,
(PCM),
assembly and the
CRT stem is 29mm ±1 mm. (See below diagram)
c) Produce a complete, red pattern on the display. Adjust the Purity magnet rings on the
PCM
assembly to obtain a complete field of the color red. This is done by moving the two tabs in
such a angle between the two tabs, which should be approximately 180°.
d) Check the complete blue and complete green patterns to observe their respective color purity.
Make minor adjustment if needed.
Purity Magnets
4-pole magnets ( Red to Blue Convergence)
6-pole magnets (Green to Magenta Convergence)
29'±1
mm
Purity, Convergence Magnet Assembly (PCM}
~
R
Perform the adjustment by opening
7
the angle between the tabs.
B/RG P 1·
h
d'
b
·
1
er arm t ea 1ustment y opening
the angle between the tabs.
B - - - ~
_l_
-- -
~
- Yt I
R
PNform the adjustment by synchronous
rotation of the two tabs.
1
Perform the adjustment by synchronous
I
rotation of the two tabs.
Red to Blue Convergence
(Magenta}
Green to Magenta Convergence
(White}
(8) Convergence Adjustment
a) Produce a magenta crosshatch on the display.
b) Adjust the focus for the best overall focus on the display.
Also adjust the brightness to the desired condition.
c) Vertical red and blue lines are converged by varying the angle between the two tabs of the
4-pole magnets on the PCM assembly. (See above diagrams)
d) Horizontal red and blue lines are converged by varying the two tabs together, keeping the angle
between them constant.
e) Produce a white crosshatch pattern on the display.
f) Vertical green and magenta lines are converged by varying the angle between the two tabs of
the 6-pole magnets.
g) Horizontal green and magenta lines are converged by varying the two tabs together, keeping the
angle between them constant.
-23-