Pepperl+Fuchs KCT2-6ST-V Manual page 11

Table of Contents

Advertisement

KCT2-6ST-V
KC-LED-96-1T-24VDC
Count frequency:
Frequency measurement
Accuracy <0.1 %
Measuring principle:
< 38 Hz:
> 38 Hz:
In case of frequencies < 10 Hz, the waiting time
must be increased accordingly to obtain the
display of a value.
AC power supply: 100 ... 240 VAC ±10%
Input level:
typ. Low Level:
typ. High Level:
Fmax:
Tacho
DC power supply:
Input level:
typ. Low Level:
typ. High Level:
Fmax:
Tacho
Counting ranges:
Seconds
Minutes
Hours
h.min.s
Accuracy
Minimum pulse length for the Reset input:
5 ms
Input sensitivity:
SELV circuits, reinforced / double insulation
Standard sensitivity:
AC power supply
DC power supply
10 / ENG
period measurement
gating time measurement
gating time 26,3 ms
Standard
2,5 V
22,0 V
kHz
60
24
12 V DC
Standard
2,5
2,0 V
22,0
10 V
kHz
kHz
60
20
0.001 s ... 999999 s
0.001min ... 999999 min
0.001 h ... 999999 h
00 h 00 min 01 s
... 99 h 59 min 59 s
<50 ppm
Low: 0 ... 4 V DC
High: 12 ... 30 V DC
Low: 0 ... 0,2 x U
[V DC]
B
High: 0,6 x U
... 30 V DC
B
Pulse shape:
Sensor supply voltage:
(Voltage output for external sensors)
SELV circuit, reinforced/double insulation
AC power supply
Ambient temperature:
Storage temperature:
Relative humidity: <85 % (non-condensing)
Altitude:
EMC:
Noise immunity:
Device safety (for the AC models):
Protection Class:
!
Only the front side is classified as acces-
sible for the operator.
Application area:
Insulation:
Front:
Rear side:
Signal inputs and
sensor power supply: SELV
Housing:
For front panel mounting:
Weight:
Protection:
any,
Schmitt-Trigger inputs
24 V DC ±15 %/100 mA
–20 ...+65 °C
–25 ... +70 °C
to 2000 m
with shielded signal and
control cables
Protection Class 2
(front side)
Pollution level 2
over-voltage Category II
double insulation
basic insulation
96 x 48 mm
acc. to DIN 43700,
RAL7021, dark grey
appr. 150 g
IP65 (front, device only)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kc-led-96-1t-24vdc

Table of Contents