Led Status Indicator, Display & Function Key - Siemens SIMATIC RTLS4084T Operating Instructions Manual

Localization systems
Hide thumbs Also See for SIMATIC RTLS4084T:
Table of Contents

Advertisement

Device description
2.3 LED status indicator, display & function key
2.3
LED status indicator, display & function key
The operating states of the transponder are indicated by the LED. The LED can be green and
red and have the states off , on
LED
LED L1
LED L2
Table 2- 3
Display
Display
F1 function key
F2 function key
10
, flashes .
Meaning
Lights up green once for 1.5 seconds when the transponder is restarted.
Briefly flashes green once when the F1 or F2 function key is pressed and the
battery voltage is sufficient.
Briefly flashes red once when the F1 of F2 function key is pressed when the
battery voltage is low. However, the transponder is available and localizable.
Lights up green once for 1.5 seconds when the transponder is restarted.
Flashes red (user LEDs flash) if you trigger flashing via the Locating Manager. You
can configure the duration and frequency of flashing via the Locating Manager.
Display and function key
Meaning
5 background images can be saved
20 text boxes with 58 characters per box
20 font types/sizes incl. bar codes
If this function key is pressed, the message is forwarded to the program
interface.
When the F1 function key is pressed, the charge state of the battery pack is
evaluated and, depending on its voltage, the LED 1 briefly flashes green or red. In
the Locating Manager, you can configure a transponder parameter to define the
threshold value below which the battery voltage is defined as too low for
operation, a "low power" message is generated and LED 1 flashes red. Refer to
the notes in the section "Installation & operation (Page 13)".
If this function key is pressed, the message is forwarded to the program
interface.
When the F2 function key is pressed, the charge state of the battery pack is
evaluated and, depending on its voltage, the LED 1 briefly flashes green or red. In
the Locating Manager, you can configure a transponder parameter to define the
threshold value below which the battery voltage is defined as too low for
operation, a "low power" message is generated and LED 1 flashes red. Refer to
the notes in the section "Installation & operation (Page 13)".
Operating Instructions, 05/2023, C79000-G8976-C626-04