NEC UNIVERGE SV9100 System Maintenance Manual page 85

Hide thumbs Also See for UNIVERGE SV9100:
Table of Contents

Advertisement

UNIVERGE SV9100
Alarm
Type
Name
No.
35
Not set CS Blocking
36
Not set CS error
notification 1
37
Not set CS transmission
error.
System Maintenance Manual
Content of Alarm
The link of the CSIU and
1. Outgoing noise.
CS came off.
Minor. Method of setting up
CS.
3. Wiring to connect CSIU
unit with CS.
4. Hard defect of CS.
5. Hard defect of CSIU.
CS detected the problem
1. Outgoing noise.
occurring in the air
synchronous signal
Minor. Method of setting up
between CS-CSIU, BBIC
CS.
reset was executed, and
it was restored
3. Wiring to connect CSIU
automatically.
unit with CS.
4. Hard defect of CS.
5. Hard defect of CSIU.
Because CS had not
1. Outgoing noise.
returned the response
to the control signal
Minor. Method of setting up
from a main device
CS.
longer than the fixed
time, it was restored
3. Wiring to connect CSIU
automatically specifying
unit with CS.
reset to concerned CS
with a main device.
4. Hard defect of CS.
5. Hard defect of CSIU.
Cause
Action
Please confirm the
following matter when
happening frequently
when operating it.
1. Please confirm CS is
normally connected.
Minor. Please confirm
the wiring between
CSIU-CS is normal.
3. Please exchange CS.
4. Please exchange
CSIU.
Please confirm the
following matter when
happening frequently
when operating it.
1. Please confirm CS is
normally connected.
Minor. Please confirm
the wiring between
CSIU-CS is normal.
3. Please exchange CS.
4. Please exchange
CSIU.
Please confirm the
following matter when
happening frequently
when operating it.
1. Please confirm CS is
normally connected.
Minor. Please confirm
the wiring between
CSIU-CS is normal.
3. Please exchange CS.
4. Please exchange
CSIU.
Issue 1.0
Recovery
The error is
recovered when
reconnecting or
exchanging it.
This error has
been recovered
when it is notified.
This error has
been recovered
when it is notified.