OPERATING AND PERFORMANCE TEST
2-1.
INTRODUCTION
2-2.
The following information is provided to determine
whether the plotter is operating properly. If operation is
not correct, refer to Section VI of this manual for service
information.
2-3.
REAR PANEL SWITCHES (Option 001)
2-4.
A3/ A4. This switch chooses between
Bl
A3 size
paper and A/ A4 size paper. The switch is used to set the
default paper size only at power up. Subsequent paper
size changes can be made from the front panel.
2-5.
BAUD RATE. Table 2-1 shows the switch settings
required. Disregard any markings on the switch itself
and use the 1 and 0 markings on the rear panel to
determine baud rate.
2-6.
PARITY. Two rear panel switches are used for
parity selection. When the SI/PARITY switch is set to 1
(ON), the S2/PARITY switch selects odd or even parity.
2-7.
MET/US. This switch is used to program the
plotting area for four paper sizes:
Paper
Switch
Maximum
Size
Position .
Plotting Area
B/A3
MET
275
x
402 mm
us
10.2
x
16.3 in.
A/A4
MET
192
x
275 mm
us
7.5
x
10.2 in.
2-8.
D/Y. When the EAVESDROP switch is in the Y
position, received data is retransmitted and the plotter
does not respond unless it is given a "Plotter On"
instruction. When this switch is in the D position, the
plotter responds to all recognized commands.
2-9.
REAR PANEL SWITCHES (Option 002)
2-10.
ADDRESS. The plotter's HP-IB address is set by
five of the seven switches on the rear panel. Disregard
any markings on the switch itself and use the 1 and 0
labels on the rear panel to determine the address in
binary coded decimal.
2-11.
A3/ A4. This switch chooses between
Bl
A3 size
paper and A/ A4 size paper. The switch is used to set the
default paper size only at power up. Subsequent paper
size changes can be made from the front panel.
2-12.
MET /US. This switch is used to program the
plotting area for four paper sizes:
Paper
Switch
Maximum
Size
Position
Plotting Area
BIA3
MET
275
x
402 mm
us
10.2
X
16.3 in.
A/A4
MET
192
X
275 mm
us
7.5
x
10.2
2-13. BASIC OPERATING TEST
2'14.
The front panel controls can be used to test basic
operation of the plotter; however, this procedure does not
test the 110 circuits.
a.
Make sure six pens are installed in pen carousel.
Table 2-1. Baud Rate Selection
ONE STOP BIT
TWO STOP BITS
REAR PANEL SWITCHES
BAUD
REAR PANEL SWITCHES
B4
B3
B2
Bl
RATE
B4
B3
B2
Bl
-
-
-
-
External
0
0
0
0
-
-
-
-
75
0
0
0
1
-
-
-
-
110
0
0
1
0
0
0
1
1
150
-
-
-
-
0
1
0
0
200
-
-
-
-
0
1
0
1
300
1
0
1
1
0
1
1
0
600
1
1
0
0
0
1
1
1
1200
1
1
0
1
1
0
0
0
2400
1
1
1
0
1
0
0
1
4800
1
1
1
1
1
0
1
0
9600
-
-
-
-
1
=
Switch Open; 0
=
Switch Closed