Training manual CLAS X
5.3.3
MINIMUM POWER CHECK.
24 kW CF
28 kW CF
24 kW FF
28 kW FF
32 kW FF
5.3.4
SOFT IGNITION POWER CHECKING
24 kW CF
28 kW CF
24 kW FF
28 kW FF
32 kW FF
Fig. D
To check the minimum power loosen screw "2"
1.
the pressure gauge fitting pipe in the pressure intake.
2.
Disconnect the compensation pipe of the air chamber (fig.B).
3.
Have the boiler work on minimum power and disconnect a cable
from the modulator (fig.D). The supply pressure must correspond with
the one foreseen for the type of gas for which the boiler has been
prearranged (refer to table below). If it does not correspond, act on
adjusting screw "4"
"3"(fig.C).
4. After checking tighten screw "2" and check sealing.
5. Reconnect the cable of the modulator.
6. Reconnect the compensation pipe
OUTLET PRESSURE MIN. POWER (mbar)
AGGIORNARE
Regulation carried out on parameter
To check the slow ignition power, loosen screw "2"
1.
insert the pipe of the pressure gauge in the pressure intake.
2.
Disconnect the air chamber compensation pipe (fig.B)(sealed
chamber).
3.
Open the tap of the hot water, the burner turns on, disconnect the
detection electrode in order to have the slow ignition pressure for 8
seconds before safety block.
4.
Change parameter
OUTLET PRESSURE SOFT IGNITION (mbar)
AGGIORNARE
(fig.D)
while holding the hexagon nut steady
G20
G30
2,2
5,5
2,5
5,3
2,3
5,5
2,5
5,1
2,3
5,2
2 20
2 20
(see paragraph 6.2 and 6.3).
G20
G30
2,2
5,5
2,5
5,3
6,3
10
5,1
9,5
5,6
12
(fig.B)
and insert
G31
6,9
7,5
7,2
7,2
6,8
(fig.B)
and
G31
6,9
7,5
12,7
13,7
12
Pag. 42 di 69
Need help?
Do you have a question about the CLAS X and is the answer not in the manual?
Questions and answers
здравствуйте . Аристон клас иккс . дом отапливается тёплыми полами и гистерезис составляет около 15 градусов в отопительном контуре . как добиться гистерезиса 5 градусов так как 15 градусов на полах очень заметно остывают полы .
To achieve a 5-degree hysteresis in the heating circuit for the Ariston CLAS X when using underfloor heating, set the thermoregulation type to "Fixed Flow Temperature" (0 = Fixed Flow) and then set the desired fixed temperature. The system allows temperature settings from 35 °C to 82 °C. Hysteresis control depends on maintaining the temperature range around the setpoint. Specific hysteresis settings are not directly mentioned, so manual adjustment of on/off thresholds around the target temperature may be required.