The label on your tool may include the following symbols. The
symbols and their definitions are as follows:
BPM .................... beats per minute
V ......................... volts
min ..................... minutes
j
or DC ............ direct current
.../min .............. per minute
RPM .................... revolutions per
minute
A ......................... amperes
Hz ....................... hertz
W ........................ watts
Wh ...................... watt hours
n o ....................... no load speed
n ......................... rated speed
c
..................... safety alert symbol

ASSEMBLY AND ADJUSTMENTS


WARNING: To reduce the risk of serious personal
injury, turn unit off and remove the battery pack
before making any adjustments or removing/installing
attachments or accessories. An accidental start‑up can
cause injury.
SPECIFICATIONS
Maximum Pounds per Square Inch
Rated Gallons per Minute
Battery
Inlet Hose
Pressure of Inlet Water
Inlet Water
Soap Consumption Rate
Attaching Quick Connect Filter (Fig. B)
This power cleaner must be used with the quick connect
adapters. The garden or suction hose can only be attached
when the quick connect filter 
1. To connect the quick connect filter 
cleaner 
 2 
, place the end of the quick connect filter onto the
water intake 
. Tighten the quick connect filter by hand.
 3 
nOTE: Avoid cross threading when installing the hose.
Cross threading will cause leaks.
To Attach the Spray Wands, Soap Bottle or other
Attachment (Fig. C)
The spray wand, soap bottle and other attachments (sold
separately) connect to the power cleaner. To connect the
spray wand 
 8 
and soap bottle 
• Insert the end of the attachment into the opening on
the power cleaner 
 2 
. Push in and turn the attachment
clockwise until it's secured into working position.
• To remove the attachment, push in and turn the
attachment counterclockwise and pull from the power
cleaner 
 2 
.
nOTE: Other accessories are available for use with this
power cleaner, refer to the Accessories section.
h
..................... wear respiratory
protection
f
..................... wear eye
protection
i
..................... Class II
Construction
(double insulated)
g
..................... wear hearing
protection
a
..................... read all
documentation
n
..................... avoid staring at
light
l
or AC............ alternating current
Ah ....................... amp hours
550
1.0
20V DC
20 ft (6 m)
20‑100 PSI
Cold Tap
10% MAX
 7 
is installed.
 7 
to the power
 11 
to the power cleaner 
To Attach the Garden or Suction Hose (Fig. D, E)
Connecting the garden hose or suction hose will depend on
the job to be performed.
To Attach Garden Hose (Fig. D)
This power cleaner must be used with the quick
connect adapters.
1. To connect the quick connect garden hose adapter 
to a garden hose, thread the quick connect garden hose
adapter onto the end of the garden hose. Tighten the
garden hose by hand.
nOTE: Avoid cross threading when installing the hose.
Cross threading will cause leaks.
nOTE: Before connecting the garden hose to the power
cleaner, run water through the garden hose for thirty
seconds to clear any debris from the mouth of the garden
pressure hose.
2. To connect the quick connect garden hose adapter 
to the quick connect filter 
the quick connect garden hose adapter firmly onto the
quick connect filter.
nOTE: Before use, gently tug on the garden hose to ensure
the connection is secured. Make sure the quick connect
garden hose adapter is flush with the quick connect filter as
shown in Figure D.
3. Always disconnect the garden hose after usage. To
disconnect, pull back the collar on the quick connect garden
hose adapter and remove from the quick connect filter.
To Attach the Suction Hose (Fig. E)
Use the suction hose to pull water from a bucket or other
fresh water source.
NOTICE: Do not use to suction soap, chemicals, dirty or
corrosive liquids, such as window cleaner, plant food,
fertilizers or bleach. Do not use salt water.
1. To connect the quick connect hose connector 
end of the suction hose to the quick connect filter 
power cleaner 
, push the quick connect hose connector
 2 
firmly onto the quick connect filter.
nOTE: Before use, gently tug on the suction hose to ensure
the connection is secured. Make sure the quick connect
hose connector on the end of the suction hose is flush with
the quick connect filter as shown in the Figure E inset.
2. Place other end of suction hose with filter on it into
container of fresh water or a fresh water source. Adjust
the float on the suction hose so the filter stays covered in
the liquid.
3. Select the correct nozzle to be used.
4. After the job being performed is complete, place the
suction hose into container of clean water and draw the
clean water through the system to rinse.
To Attach Nozzle to Spray Wand (Fig. F)

DANGER: Risk of fluid injection. Do not direct discharge
stream toward persons, unprotected skin, eyes or any pets or
 2 
:
animals. Serious injury will occur.

WARNING: Flying objects could cause risk of
serious injury. DO NOT attempt to change nozzles while
power cleaner is running. Turn power cleaner off before
changing nozzles.
To connect the nozzle 
the quick connect collar 
insert the appropriate nozzle. Release the quick connect
collar to lock the nozzle in place.
 7 
on the power cleaner 
 10 
,
 15 
to the spray wand 
toward the spray wand and
 9 
English
 16 
 16 
 2 
, push
 13 
on the
on the
 7 
 8 
, pull
7

Advertisement