OPERATION

3.20.3 RECEIVER PANEL WITH MONITOR BOX

Legend for illustration Z 22469:
3
Service arm, hydraulically operated
4
Monitoring and control box
5
Push button for testing lamps (6, 7, 8, 9, 10 and 11).
Push the button, all lamps must light up. If a lamp does
not light up, corrective action must be taken.
6
Indicator lamp, fuel tank full. (H139)
7
Indicator lamp, grease container of Central lubrication
System FULL. (H76)
8
Indicator lamp, grease container of Swing circle pinion
Lubrication System FULL. (H78)
9
Indicator lamp, engine oil reserve tank for Front engine 2
FULL. (H142-2)
10
Indicator lamp, engine oil reserve tank for Rear engine 1
FULL. (H142-1)
11
Indicator lamp, main hydraulic oil reservoir FULL.
Recheck hydraulic oil level at the sight gauge before
operating the machine. (H52)
12
Receiver panel
Fuel filling adapter, observe lamp (6).
13
REMARK
The fuel nozzle cut-out pressure should be adjusted
to 0,38 bar. If this pressure is too low for filling the fuel
tank up to the correct level, gradually increase the cut-
out pressure until the pressure is sufficient for filling up
to the correct level
The maximum flow rate should not exceed 680 liter per
minute.
14
Adapter for filling the grease container of the Central
Lubrication System (CLS). Before filling the grease con-
tainer make sure the grease filter in the filling line is not
obstructed. Observe lamp (7).
15
Adapter for filling the grease container of the Swing cir-
cle pinion Lubrication System (SLS). Before filling the
grease container make sure the grease filter in the filling
line is not obstructed. Observe lamp (8).
16
(Fr.) Front engine, (Rr.) Rear engine. Oil evacuation and
filling adapter connected to the engine oil pan. Monitor
oil level at level gauge.
3.20 CENTRAL REFILLING SYSTEM