Installation and Operating Manual
TTXII Swing Door Operator

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TTXII and is the answer not in the manual?

Questions and answers

Summary of Contents for Tormax TTXII

  • Page 1 T-1132 e 1.09 US801465 V1.4 and up Installation and Operating Manual TTXII Swing Door Operator...
  • Page 2: Table Of Contents

    Contents Introduction Safety General Safety and Accident Prevention Regulations Safeguarding Danger Points Organizational Measures 7 - 8 Basic Functions Installation Outswing Surface Mount With 0” to 9 -7/8” Reveal Inswing Surface Mount With 0” Reveal Inswing Surface Mount With Deep Reveal Double Egress with Surface Mount Mechanical Adjustments Electrical Connections and Wiring Diagrams...
  • Page 3: Introduction

    These instructions are addressed to AAADM Certified installation and service Adressee technicians. This document is applicable to the Tormax TTXII swing door operator with SW 1.4 Area of Application and up. Non-compliance endangers the safety of the installation personnel, the system op- Explanation of Symbols erator or the user.
  • Page 4: Safety

    Always use appropriate tools for installation and repair. Prior to commissioning or performing any work on the door system, the operating in- structions for the TORMAX operator and the following safety directions should be studied with great care and must be observed!
  • Page 5: Safeguarding Danger Points

    The TORMAX operator is designed according to the current state of technology as Intended Purpose well as the recognized safety-relevant regulations and is intended exclusively for the deployment in conjunction with automatic interior and exterior doors (without wind loads) used by people e.g. in hospitals, homes for the elderly, shopping centres, of ce buildings and large-scale enterprises.
  • Page 6: Organizational Measures

    Service Technicians in accordance with the latest ANSI A156.10 or A156.19 standard. Contact Tormax for training classes conducted at our facility if you wish to attend a factory training class. Use the system only in a technically sound state. Eliminate faults immediately that Fundamental Safety Mea may impair safety.
  • Page 7: Basic Functions

    Basic Functions Motion Control – General The door opens motor-driven in accordance with the stored speed pro le (see section 7.1) against the installed spring. If the motor torque decreases the door is braked down by the spring. The door is held in the open position by a reduced motor torque. The closing action is performed through spring force only.
  • Page 8 An opening can be initiated by an activator, a key switch and also by “Push and Go” Operating Mode AUTO depending upon con guration. The door opens and stops in open position. It opens according to the settings of “Teach- Operating Mode OPEN In General”.
  • Page 9: Installation

    Installation...
  • Page 13: Mechanical Adjustments

    Mechanical Adjustments An external door stop may be installed as shown but you must leave a 3/8” space between the door and any physical stop. The door should only be opened so far that the standard linkage cannot tip over and the sliding lever does not leave the rail.
  • Page 14 Electrical Connections 10AT 230/115V~ 50/60 Hz T1132/1 Mains Connection Before beginning the work described here check that the mains supply is switched off. If possible, route the mains connection along the side of the power supply to the op- erator. The connecting cables must be of the type “PVC cable H05VV-F”...
  • Page 15 Terminal Connections ** OFF AUTO OPEN Safety devices without monitoring – – Activator +24 V Key switch 24 V – Door lock 24 VDC locked currentless No protective +24 V * unlocked currentless circuit necessary Status indication door closed/*open 24 V +24 V Legend: programmable...
  • Page 22: Commissioning With "Teach-In General

    Commissioning the TTXII Operator The activating devices are installed to the latest ANSI A156.10 Requirements and / or A156.19 standard. before Commissioning The operator is secured with appropriate fasteners. The internal stop is adjusted correctley. The all wires are no in the path of moving parts.
  • Page 23: Programming Examples

    Programming Examples Program the desired functions now in sequence in accordance with the programming table. (Turn Push and Pull off Solid 1 Flashing “1”) Example 1 1. Simultaneously press and release the yellow and blue buttons for 1 second, Immediatley press the yellow button (step do not hold down) til a solid number 1 is displayed, Immediatley press and release the blue button and a flashing “0”...
  • Page 24: Programming Table

    Programming Table (Teach-In Solid 0 flashing “0”) Simultaneously press and release the yellow and blue buttons for 1 second, Immediatley press the yellow button and a solid 0 will display, Immediatley press the blue button and a flashing “0” will display, Immediatley open the door to 90 degrees at a fast speed, hold the door open for the amount of hold open time, allow the door to spring close to the full closed position then Immediatley push the door open 6”...
  • Page 25 Programmable Functions Function Para- Description of Function meter Teach-In General Programs the door to your opening specifications Opening and closing speed, open position, hold-open time, disabling angle for safety device in opening direction The behaviour applies to opening through activators, key switches and Push-and-Go. The technician must perform the “Teach-In General”...
  • Page 26 Function Para- Description of Function meter Open and closing speed 0...9 This adjustment is a governor for the opening and closing speed. It is recommended the speed during Teach-In General be performed fast and then use this adjustment as governor to adjustment limit the opening and closing speeds.
  • Page 27 Simultaneous pairs or Double Egress doors Electrical Connections As described in Chapter 6, the following instructions also apply: Always operate both units directly connected to the same power supply (L1, N, PE). Both units must have the same earth ground! So that data can be exchanged between the two control units, both RS232 interfaces must be connected with interface module 406079.
  • Page 28 (Teach-In Solid 0 flashing “0”) Secondary operator 3. Simultaneously press and release the yellow and blue buttons for 1 second, Immediatley press the yellow button and a solid 0 will display, Immediatley press the blue button and a flashing “0” will display, (Caution the Primary door will open then close after the Secondary door has been taught in, make sure the door area is free of any obstruction) Immediatley open the door to 90 degrees at a fast speed, hold the door open...
  • Page 29: Trouble Shooting

    Trouble shooting Fault pattern Cause Door doesn‘t open – Safety device in opening direction is active or the cable is interrupted or jumper 14-15 is missing – The safety device for the swing area is active or the cable is interrupted or jumper 18–19 is missing –...
  • Page 30 Your First Choice for Door Automation TORMAX Sliding Doors TORMAX Swing Doors TORMAX Folding Doors TORMAX Revolving Doors TORMAX Slide-Swing Doors TORMAX TECHNOLOGIES, INC. 12859 Wetmore Road San Antonio, TX 78247 210-494-3551 210-494-5930 (FAX) 888-685-3707 WWW.TORMAXUSA.COM INFO@TORMAXUSA.COM...