Replace Outdoor Fan Blade And Motor - Friedrich ZoneAire Premier R-32 Series Service Manual

Packaged terminal air conditioners & heat pumps, standard chassis r-32 refrigerant 230/265 volt
Hide thumbs Also See for ZoneAire Premier R-32 Series:
Table of Contents

Advertisement

Unit Disassembly and Component Replacement

Replace Outdoor Fan blade and motor

Warning:
Ensure there are no open flame sources or hot
surfaces that exceed 1200˚F in the work area.
Warning:
Discharge capacitors in a way that won't cause
any spark. The standard procedure to short circuit the capacitor
terminals usually creates sparks.
1.
Remove Front panel.
2. Open electrical box and disconnect wiring to outdoor fan.
See Figures 503 thru 507.
3. Remove middle connection brackets. See Figure 524.
middle
connection
bracket
4. Remove outdoor fan shroud. See Figure 525.
50
screws
middle connection bracket
Figure 524
screws
Outdoor
Fan Shroud
Figure 525
5. Remove nut on fan blade. See Figure 526.
6. Remove Outdoor Fan screws. See Figure 526.
nut
motor
screws
Figure 526

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZoneAire Premier R-32 Series and is the answer not in the manual?

Questions and answers

Table of Contents