Schwesternruf (checkbox)
When enabled, Nurse Assist alarms can be raised by pressing the
EkoCare device in this Mode. On EkoCare Units, the number of times a button must be
pressed to raise an alarm is set as 1 and cannot be changed.
If the Anwesenheit setting is enabled in the same device mode (see section 5.4.7), the
BLUE
Nurse Assist alarm button raises a Patient Call alarm unless the
Present button has been pressed to indicate the presence of a responder. While the Nurse
is present, the Nurse Assist button raises Emergency alarms when pressed. A second
press of the Attendance button clears any active alarms raised from the device and returns
the Nurse Assist button to Patient Call mode.
If the Nurse Call setting is disabled, the
Alarmtext (text field)
This setting defines the message text that is sent to other devices when a Nurse Assist
alarm is raised from devices in this Mode. This is set as Assistenz by default. The
Schwesternruf setting must be enabled for this setting to apply.
To customise this message, enter an alphanumeric string into the text field (maximum 20
characters).
5.4.25 SCHWESTERNRUFBETRIEB SETTINGS [CALL POINT AND FOB
DEVICES]
These settings enable the alarm buttons on Call Point and Fob devices in this Mode to be
used to raise Patient Call alarms, and the way in which the device responds when this
occurs. If Schwesternrufbetrieb is enabled for a Call Point or Fob, all alarm buttons raise
a Patient Call alarm when pressed.
Fig. 52 The Schwesternruf settings as available to Call Point and Fob Device Modes
If a Call Point is linked to an EkoCare Unit for which the Attendance setting has been
enabled and is currently active (i.e., the
Presence at an earlier alarm), all alarms raised by the Call Point until the Nurse Presence
has been cleared (i.e., the
original alarm) are treated as an Emergency Alarm. Alarms raised by the Call Point during
this time inherit the message code configured in the Notruf – Alarmtext setting of the
linked EkoCare Unit.
PLEASE NOTE: Enabling Schwesternrufbetrieb for Fob devices causes all alarm
buttons on the device to raise a Patient Call alarm when pressed. Automatic alarms,
BLUE
button raises a Patient Call when pressed.
GREEN
button has been pressed to indicate Nurse
GREEN
button has been pressed a second time to clear the
EkoSecure DIN VDE V 0825-1 compliant Hub Administrator Guide
5 Konfiguration menu
BLUE
button on an
GREEN
Nurse
9262-0119 Issue I
57