Slope sensor kit

Advertisement

Calibrating the Sensor
Note:
When you first turn the ignition key to on,
the InfoCenter shows advisory 194, Calibrate Slope
Sensor.
1.
While on a flat surface, remove the plug from
the calibration connectors
1. Calibration connectors
2.
Plug the calibration connectors together as
shown in
Figure
3.
Turn the ignition key to the O
not start the engine.
4.
The InfoCenter shows advisory 195, Slope
Sensor Calibrating.
Note:
The LED light at the top of the display
screen
(Figure
8) blinks as the sensor calibrates.
(Figure
7).
Figure 7
2. Plug
7.
position, but do
N
1. LED light
5.
When the InfoCenter shows advisory 196, Slope
Sensor Calibrated, and the light no longer blinks,
turn the ignition key to the O
g317369
6.
Disconnect the calibration connectors and install
the plug onto the connectors
1. Calibration connectors
g317368
Updating the Machine
Software
Check and ensure your machine software is at
revision W or higher. Contact your authorized Toro
distributor to update the machine software.
5
Figure 8
position.
FF
(Figure
9).
Figure 9
2. Plug
g317524
g315597

Advertisement