Download Print this page
Toro 08865 Installation Instructions Manual
Toro 08865 Installation Instructions Manual

Toro 08865 Installation Instructions Manual

Laser level installation kit for field pro 6040 traction unit

Advertisement

Quick Links

Laser Level Installation Kit
Field Pro
Model No. 08865
Installation
Loose Parts
Use the chart below to verify that all parts have been shipped.
Procedure
1
2
3
4
© 2023—The Toro® Company
8111 Lyndale Avenue South
Bloomington, MN 55420
®
6040 Traction Unit
Description
No parts required
No parts required
Bolt (3/8 x 1/2 inch)
Flat washer
Spacer
Locknut (3/8 inch)
Curved washer
Bushing
Receiver mast
Locknut (1/2 inch)
Thrust washer
Mast-support mount
Carriage bolt (1/2 x 2-1/2 inches)
Carriage bolt (3/8 x 1-1/4 inches)
Hydraulic hose (65 cm or 25-1/2 inches)
Hydraulic hose (48 cm or 19 inches)
Long hydraulic tube (mid-port)
Short hydraulic tube (mid-port)
Hydraulic tube (no port)
Hydraulic hose (90° elbow fitting)
Long 90° elbow fitting
Short 90° elbow fitting
Straight fitting
Carriage bolt (5/16 x 3/4 inch)
Control manifold
Valve bracket
Bolt (1/4 x 5/8 inch)
Nut (5/16 inch)
Register at www.Toro.com.
Form No. 3459-473 Rev B
Installation Instructions
Qty.
Prepare the machine.
Remove the hood.
2
4
2
3
2
2
Install the receiver mast.
1
1
1
1
1
2
1
1
1
1
1
1
1
Install the hydraulics.
1
2
2
1
1
3
2
Original Instructions (EN)
Printed in the USA
All Rights Reserved
Use
*3459-473*

Advertisement

loading

Summary of Contents for Toro 08865

  • Page 1 Form No. 3459-473 Rev B Laser Level Installation Kit Field Pro ® 6040 Traction Unit Model No. 08865 Installation Instructions Installation Loose Parts Use the chart below to verify that all parts have been shipped. Procedure Description Qty. – No parts required Prepare the machine.
  • Page 2: Preparing The Machine

    Procedure Description Qty. Bolt (1/4 x 5/8 inch) Locknut (#6) Carriage bolt (#10 x 5/8 inch) Laser controller mount Install the laser controller mount. Nut (#10) Grommet Screw (#6 x 1/2 inch) Nut (1/4 inch) Switch bracket Proximity switch Switch plate Carriage bolt (#10 x 5/8 inch) Locknut (#10 inch) Install the operator presence switch.
  • Page 3: Removing The Hood

    Removing the Hood No Parts Required Procedure Remove the latches from the latch pins (Figure g362440 Figure 1 1. Latch 2. Latch pin Lift the hood from the machine (Figure g362438 Figure 2...
  • Page 4 Installing the Receiver Mast Parts needed for this procedure: Bolt (3/8 x 1/2 inch) Flat washer Spacer Locknut (3/8 inch) Curved washer Bushing Receiver mast Locknut (1/2 inch) Thrust washer Mast-support mount Carriage bolt (1/2 x 2-1/2 inches) Carriage bolt (3/8 x 1-1/4 inches) g389485 Figure 3 Procedure...
  • Page 5 Install the mast to the mast-support mount as shown in Figure Install the upper part of the mast to the machine fork as shown in Figure Installing the Hydraulics Parts needed for this procedure: Hydraulic hose (65 cm or 25-1/2 inches) Hydraulic hose (48 cm or 19 inches) Long hydraulic tube (mid-port) Short hydraulic tube (mid-port)
  • Page 6 Remove the existing hoses from the cylinder and the control valve (Figure g389240 Figure 6 g389238 Figure 5 1. Control valve end 2. 90° elbow fitting 1. Existing hoses for the cylinder Remove the 90° elbow fitting from the cooler and at the front of the control valves (Figure 6 Figure...
  • Page 7 g389239 Figure 7 1. Control valve end Install the 90° elbow fittings, straight fittings, and the bracket to the control manifold (Figure g389237 Figure 8 1. 90° elbow fitting (short) 4. Valve bracket 2. 90° elbow fitting (long) 5. Bolt (1/4 x 5/8 inch) 3.
  • Page 8 Install the control manifold and bracket to the Figure 10 to identify the hydraulic tubes and machine as shown in Figure the hoses. g389303 Figure 10 1. Hydraulic hose (90° elbow 4. Long hydraulic tube fitting) (mid-port) 2. Hydraulic hose (48 cm or 5.
  • Page 9 Install the hydraulic hose (90° elbow fitting) to the straight fitting on the manifold, route it back to the hydraulic fluid cooler, and attach the 90° elbow fitting to the hydraulic fluid cooler; refer to Figure Figure 11, and Figure Note: Ensure the hose is routed away from hot surfaces, not rubbing on other parts, and not...
  • Page 10 Install the short hydraulic tube (mid-port) to the Install the long hydraulic tube (mid-port) to the valve control and the 90° elbow fitting (short) on valve control and the 90° elbow fitting (long) on the manifold; refer to Figure Figure 10, and the manifold;...
  • Page 11 Installing the Laser Controller Mount Parts needed for this procedure: Bolt (1/4 x 5/8 inch) Locknut (#6) Carriage bolt (#10 x 5/8 inch) Laser controller mount Nut (#10) Grommet Screw (#6 x 1/2 inch) Nut (1/4 inch) g389243 Figure 15 Procedure 1.
  • Page 12 g389352 g389353 Figure 17 1. Grommet 7. Laser controller mount 2. Locknut (#6) 8. Carriage bolt (#10 x 5/8 inch) 3. Locknut (#10) 9. Laser controller mount with grommet 4. RAM ® mount—provided in the display kit 10. Nut (1/4 inch) 5.
  • Page 13 Assemble the switch plate and the proximity switch to the switch bracket using a carriage bolt (#10 x 5/8 inch) and locknut (#10) as shown in Figure Installing the Operator Note: Route the wire connector (not shown) of the proximity switch up through the hole in the Presence Switch switch bracket.
  • Page 14 Install the proximity switch assembly to the Install the flange bushing and spring to the chassis using 2 carriage bolts (1/4 x 3/4 inch) activator bracket (A of Figure 21), then install and locknuts (1/4 inch) as shown in Figure the assembly to the forward joint of the standing platform (B of Figure...
  • Page 15 Remove the jumper from the machine wire Connect the proximity switch to the machine harness connector that hangs near the forward wire harness connector as shown in Figure joint of the standing platform (Figure 22). g411719 Figure 22 1. Machine wire harness 3.