6702 HERCULES SURGICAL TABLE OWNER'S MANUAL (Includes Operation, Maintenance and Parts) Read this manual before operating the table! This information is necessary for the safe and efficient operation of the equipment. TEC-D-0083 REV6 09/27/2017...
Page 2
The base language for this document is ENGLISH. Any translations must be from the base language document. Printed copies are not controlled documents. Although current at the time of publication, SKYTRON'S policy of continuous development makes this manual subject to change without notice. If current manuals are required, contact your local SKYTRON representative or contact SKYTRON...
Prior to use, all personnel that may operate this table must be instructed in the correct operational a. Remove the power cord. procedures. The 6702 HERCULES surgical table is b. Place the main POWER SWITCH in the OFF designed for use by trained and qualified personnel position.
Page 7
WARNING - Possible Pinch / Crush Points HEAD AND BACK LEG SECTION AND LEG SECTION AND SECTION CAN FLOOR CAN COLLIDE ELEVATION COLUMN COLLIDE WITH BASE CAN COLLIDE Figure 1-1. Possible Pinch or Crush Points 6702 HERCULES Owner's • REV6...
Consult with Skytron before reversing DO NOT use the table to transport a patient on the table. a patient. There is a risk of injury to the patient and staff if the patient should fall during transport. 6702 HERCULES Owner's • REV6...
Page 9
Patient's head must be on the after rotation. DO NOT rotate the top head section. Head section with an unevenly distributed patient must be attached in its normal weight load as instability may result. orientation to the table's back section. 6702 HERCULES Owner's • REV6...
Page 10
NOTICE inoperable. Indicates important information not related to Refer all service to a SKYTRON personal injury. authorized service representative. 6702 HERCULES Owner's • REV6...
Maximum Lifting Capacity: 1200 lbs (540 kg) Condensation) Maximum Articulating Capacity: 1000 lbs (450 kg) Atmospheric Pressure: 21 in-Hg to 30 • Unit Weight: 750 lbs (340 kg) in-Hg (700 hPa to 1000 hPa) Maximum Patient Weight: (1200 lbs (540 kg) 6702 HERCULES Owner's • REV6...
MAIN POWER SWITCH FLOOR/LOCK BRAKE Figure 3-1. 6702 Surgical Table 3-1. General NOTICE The 6702 HERCULES surgical table is an electro- The battery charging indicator (BATTERY hydraulically operated, general purpose surgical INDICATOR) and foot control connector table (Figure 3-1). are also located on the electrical panel.
If any of the buttons on the pendant control are pressed continuously for longer than 4 minutes, the thermal protector of the solenoid valve will actuate and the operation will be stopped. The thermal protector will reset in approximately 30 minutes. 6702 HERCULES Owner's • REV6...
BATT ON/OFF button on earth ground is compromised, equipment the pendant control to turn the battery power must be operated in battery mode. OFF. 6702 HERCULES Owner's • REV6...
The table can be operated on AC power In charging mode, three (3) green LEDs, four (4) while the battery is being charged. yellow LEDs, and one (1) red LED are turned on sequentially, then turned off, and then turned on 6702 HERCULES Owner's • REV6...
(Figure 3-9) for proper patient observation and The brake delay circuit automatically retracts the access to the emergency stop switch. brake system. It takes approximately 7-8 seconds to totally release the system. 6702 HERCULES Owner's • REV6...
Page 20
To move the table safely, one staff (head up) position, press the REV TREND button. member should be positioned at Reverse Trendelenburg positioning of up to 30° the head end and one at the foot may be obtained. 6702 HERCULES Owner's • REV6...
Page 21
23-5/8 inches (600 mm). DOWN Leg Section To lower the leg section, press the LEG DOWN button. The leg section will go down to 100° below horizontal (Figure 3-15). 40° Figure 3-13. Back Section Positioning 6702 HERCULES Owner's • REV6...
Page 22
When the REFLEX button is activated, if Figure 3-18. Return To Level the kidney bridge is up, the back section will not go above horizontal. NOTICE Elevation and brake system functions are not affected by the Return To Level function. 6702 HERCULES Owner's • REV6...
(Figure 3-22). REV. TILT BACK TABLE BRAKE TREND RIGHT LOCK TILT BACK TABLE KIDNEY Figure 3-20. Emergency Stop Switch TREND LEFT DOWN DOWN DOWN DOWN Figure 3-22. Emergency Back-Up Controls 6702 HERCULES Owner's • REV6...
An uneven patient control will have to be pressed to reset weight load may cause instability. the timer circuit before brakes will lock If circumstances demand table again. brakes to be unlocked: 6702 HERCULES Owner's • REV6...
2. Simultaneously depress both release levers, then pull the section out. 3. Press the LEG DOWN or BACK DOWN button on the pendant control to position the attachment pins down and out of the way. 6702 HERCULES Owner's • REV6...
Page 26
Always lock the table top in position A table support rod is required for after rotation. DO NOT rotate the top 90° positioning. with an unevenly distributed patient weight load as instability may result. 6702 HERCULES Owner's • REV6...
Compliance with IEC60601-1 edition 3 has been confirmed without the pad set. The SKYTRON pad sets are available in 2 inch (51 mm) or larger thickness and have a velcro strip which holds them in place on the table surface.
Page 28
Page 25 6702 General Purpose Patient Positioning Guidelines Upper Body Imaging Lower Body Imaging Lap Nissen Urology Ophthalmic/ENT Nephrectomy Accessories shown may not be available in all markets. Contact your SKYTRON Representative for details. 6702 HERCULES Owner's • REV6...
Page 29
Page 26 6702 General Purpose Patient Positioning Guidelines (Cont'd) Neuro (Neck) Neuro (Lumbar) Shoulder Arthroscopy Neuro (Head) Hip Revision Cardiovascular Accessories shown may not be available in all markets. Contact your SKYTRON Representative for details. 6702 HERCULES Owner's • REV6...
Page 30
Page 27 6702 Bariatric Recommended Patient Positioning Guidelines Cysto/GYN Gall Bladder Abdominal Accessories shown may not be available in all markets. Contact your SKYTRON Representative for details. 6702 HERCULES Owner's • REV6...
IF POSITIONED WITHIN THE BLUE RANGE, WEIGHT CAPACITY IS 1,200 LBS (540 KG). BUT A HEAVY DUTY SUPPORT ROD MUST BE.USED ON THE BACK SECTION. THE TABLE CANNOT BE ARTICULATED WHEN THE SUPPORT ROD IS USED. TOP ROTATED 180° BACK 37” (940mm) 6702 HERCULES Owner's • REV6...
Page 32
WEIGHT CAPACITY 1,000 LBS (450 KG) BACK WITH BACK OVER THE LONG PART OF THE BASE. 23” ROTATED 180° MAXIMUM (584mm) WEIGHT CAPACITY IS 800 LBS (360 KG). WARNING Consult with Skytron before reversing a patient on the table. 6702 HERCULES Owner's • REV6...
Ensure that the active WARNING ingredients of the product are compatible with the materials of the SKYTRON table. Personal injury to patient or staff 6. Apply cleaning fluid liberally to top and sides may result from a lack of proper of each pad and wipe with a clean lint-free maintenance of this equipment.
4-2. Routine Inspections and services are recommended to ensure the CAUTION serviceability and proper operation of your SKYTRON surgical table. Maintenance must be DO NOT use the table if any of the performed by a SKYTRON authorized service inspection points fail.
The status of Battery Indicator is Fuse requires replacement Contact SKYTRON Service. 2 Red Replacement of fuse must be performed by a certified SKYTRON technician. 4-4. Operator Troubleshooting Annually or as required based on usage, the following checks and services should be performed: When troubleshooting a table malfunction, first a.
Page 36
7. Ensure the head section is level (parallel to the floor) and even with the back section. 9. Place an X-ray top into the table top sections If it is not, notify a certified SKYTRON to ensure that it has a snug fit. technician.
Page 37
3. Remove the oil filler cap from the oil reservoir post is installed and is securely attached. (Figure 4-5). 5. Observe that the pendant control cover is not torn or has sections missing. Replace as needed. 6702 HERCULES Owner's • REV6...
Page 38
7. Connect the correct wires to the battery 2. Carefully remove the service access cover terminals as shown in Figure 4-8. without disconnecting the cord attached to the cover. 6702 HERCULES Owner's • REV6...
Overall appearance and cleanliness 4-7. Disposal Instructions CAUTION The end of the useful life for the SKYTRON surgical If the table is stored for a period greater table is 10 years under normal operating conditions. than 6 months, the batteries should Service parts are available for this period.
For optimal usage, safety and longevity of the product, The specific items listed in the MAINTENANCE have it serviced only by a SKYTRON authorized MATRIX should be inspected and repaired or service representative using SKYTRON authorized replaced as necessary.
Page 38 SECTION 5. REPLACEMENT PARTS Replacement parts listed in this section have been NOTICE identified by SKYTRON as servicable by facility The following abbreviations are used personnel and are available for purchase. To obtain in this section: SKYTRON certified parts and authorized service, •...
Class A IEC 61000-3-2 and those directly connected to the public low- voltage power supply network that supplies buildings Voltage fluctuations / used for domestic purposes. flicker emissions Complies IEC 61000-3-3 6702 HERCULES Owner's • REV6...
Page 48
NOTE 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. 6702 HERCULES Owner's • REV6...
Page 49
3 A / m 3 A / m magnetic field location in a typical IEC 61000-4-8 commercial or hospital environment NOTE: U is the a.c. mains voltage prior to application of the test level. 6702 HERCULES Owner's • REV6...
Page 50
If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the 6702 Surgical Table. Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. 6702 HERCULES Owner's • REV6...