Electrical Section - Kenwood CK305-1 Instructions For Use Manual

Dual fuel cooker
Table of Contents

Advertisement

10 - ELECTRICAL INSTALLATION
IMPORTANT: The appliance must be installed in accordance with the manufacturer's
instructions. Incorrect installation, for which the manufacturer accepts no
responsibility, may cause damage to persons, animals and property.
The connection of the appliance to earth is mandatory. The manufacturer declines
all responsibility for any inconvenience resulting from the inobservance of this
condition.
Before carrying out any work on the electrical parts of the appliance, the appliance
must be disconnected and locked off from the mains.
The appliance must be connected to the electrical network verifying that the voltage
corresponds to the value indicated on the specifications plate and that the cables section
of the electrical wiring can bear the load which is indicated on the rating plate .
We recommend that the appliance is connected by a suitably qualified person who will
comply with the current IEE and local regulations .
The appliance must be connected via 13 Amp switched fuse spur, with a minimum opening
between the contacts of 3 mm .
The appliance must be connected to a SWITCHED FUSED SPUR OUTLET, similar to that
shown in fig. 10.1 and should be accessible and no more than 2 metres away from the
appliance .
Alternative connection methods may be available as long as they conform to current IEE
wiring regulations .
The power supply cable must not touch the hot parts and must be positioned so that it does
not exceed 75°C at any point .
Once the cooker has been installed, the switch must always be accessible .
36
SWITCHED FUSED
SPUR OUTLET
FUSE
Use a suitable FUSE in accordance
with the appliance power rating
Fig . 10 .1
ON

Advertisement