ABB IPS/S 2.1 - IP-Interface Manual

Device Connection

Device Connection

  1. ON LED
  2. LAN/LINK-LED
  3. Telegram LED
  4. 10...30 VDC connection
  5. KNX connection
  6. Programming LED
  7. Programming button
  8. Type-plate holder
  9. LAN/Ethernet connection

Device Description

The IP Interface converts telegrams on the KNX into IP telegrams on the Ethernet network according to the configuration in the ETS. In this way, data can be exchanged between the KNX and the IP network. The IPS/S fulfils the requirements of the EIBnet/IP specification. Together with the ETS (from ETS 3.0d), the IPS/S can also program devices via an LAN.

Technical Data (excerpt)

Technical Data

Operating voltage 10...30 VDC
Power consumption Max. 190 mA @ 10 V
Temperature range 0°C... + 45°C (operation)
- 25°C... + 55°C (transport/storage)
Protection class IP20 in accordance with EN 60 529
Safety class II
KNX connection Via bus connection terminal
LAN connection 10/100 BaseT, IEEE 802.3 via RJ45 connector
Weight 0.1 kg

Operating and Display Elements

On
Lights green when the power supply is available and the device is ready for operation (approx. 80 sec after connection of power supply); blinks green when the devices starts or if an error has occurred.

LAN/LINK
Lights yellow when the connection to the Ethernet network has been set up; blinks yellow during data traffic.

Programming LED and button
Lights red when the device is in programming mode (after programming button has been pressed).

Installation

The device is suitable for installation in distribution boards or small enclosures and can be snapped onto 35 mm mounting rails according to DIN EN 60 715.
Ensure that after the installation the device is always accessible for operation, testing, inspection, maintenance or repair.

Connection

The terminal designations can be found on the housing. The connection to the KNX is made via the enclosed bus connection terminal.
The connection to the IP network (LAN) is set up via a connection with the RJ45 connector.

Commissioning

The physical address and the parameter settings are set using the Engineering Tool Software ETS (from Version ETS 3.0d).

information A detailed description of the parameter configuration and commissioning steps can be found in the technical data. This information can be downloaded from the Internet site: www.abb.com/KNX


warning Installation and commissioning of the device may only be carried out by trained electricians. The relevant standards, directives, regulations and instructions must be observed when planning and implementing the electrical installation.

  • Protect the device against moisture, dirt and damage during transport, storage and operation!
  • Do not operate the device outside the specified technical data (e.g. Temperature range)!
  • The device may only be operated in closed enclosures (e.g. distribution boards)

Cleaning

Should the device become soiled, it may be cleaned with a dry cloth. If this does not suffice, a cloth lightly moistened with soap solution may be used. On no account should caustic agents or solvents be used.

Maintenance

The device is maintenance free. Should damage have occurred, e.g. due to transport or storage, no repairs should be carried out.

The warranty expires if the device is opened!

ABB STOTZ-KONTAKT GmbH
Eppelheimer Straße 82, 69123 Heidelberg, Germany
Postfach 10 16 80, 69006 Heidelberg, Germany
+49 (0) 6221 701 607
+49 (0) 6221 701 724
www.abb.com/knx
www.abb.com/stotz-kontakt

Technische Helpline / Technical Support:
+49 (0) 6221 701 434
E-Mail: knx.helpline@de.abb.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download ABB IPS/S 2.1 - IP-Interface Manual

Advertisement

Need Assistance?

Do you have a question about the IPS/S 2.1 that isn't answered in the manual? Leave your question here.

Error while submitting your question. Please, reload page and try again.

Thank you! Your question has been received!

Table of Contents