NEC Built-In AIT User Manual page 28

Table of Contents

Advertisement

3
Attach the cover to the basic processing unit. Plug the power cable to the outlet.
4
Turn on the basic processing unit.
5
When the SCSI bus can be set on the side of the basic processing unit, set the following on the
Built-In AIT.
• Transfer rate
• Data bus width
• DISCONNECT/RECONNECT function
This device has a maximum transfer rate of 160 Mbyte/second. Set the transfer rate to 160
Mbyte/second on Built-In AIT units that support it, and to the next greatest transfer rate under
160 Mbyte/second on those that do not.
When using the Ultra 160 or higher SCSI controller board, set to 160 Mbyte/second.
Also, when the N8141-28AF/-28BF expansion unit is connected, even if the transfer rate of
the Built-In AIT is 160 Mbyte/second, set it to the next greatest transfer rate under
160 Mbyte/second.
For details, see the instruction manual provided with the basic processing unit.
Important
Set the maximum transfer rates as follows according to the number of devices connected to the
bus and the SCSI cable length.
The following are standard values.
If you have other specifications at your disposal, use them over the ones below.
SCSI ID
Ultra 160 SCSI
Ultra 2 Wide SCSI
Ultra Wide SCSI
Ultra Wide SCSI
Ultra Wide SCSI
Fast Wide SCSI
Wide SCSI
* When the SCSI host and all devices connected to the same bus are LVD-compatible.
28 Built-in AIT
Maximum transfer
rate (Mbyte/s)
width (bit)
160
80
40
40
40
20
10
: 160 Mbyte/second (max., synchronous)
: 16 bits (Ultra Wide SCSI, LVD/SE)5
: Enable
Data bus
Maximum cable Maximum number
length (m)
Single-ended
16
4
16
-
16
3
16
1.5
16
-
16
3
16
6
of devices
(SCSI host +
LVD*
number of devices)
12
16
12
16
-
4
-
8
3
16
3
16
3
8

Advertisement