Page 1
Mira Move 8.5, 9.5, & 10.8 kW For SPARES, ADVICE or REPAIRS Please call us on 0844 571 5000 (UK Only) These instructions must be left with the user Installation and User Guide...
Page 2
Products manufactured by Kohler Mira Ltd are designed to be safe provided, that they are installed used and maintained in good working order, in accordance with our instructions and recommendations.
9. DO NOT perform any unspecified modifications to the shower or its accessories. When servicing only use genuine Kohler Mira replacement parts. 10. If the shower is dismantled during installation or servicing then upon completion the product must be inspected to ensure all electrical connections are tight and that there are no leaks.
PACK CONTENTS Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. 1 x Blank Insert 1 x Mira Move Electric Shower 1 x Insert RH 1 x Insert LH Documentation 1 x Installation Guide 1 x Installation Template...
INSTALLATION REQUIREMENTS Please read the Important Safety Information and specifications sections at the front of this guide, and the requirements detailed in this section before installing the shower. WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Plumbing The plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice...
Page 8
15. A full bore/non restrictive servicing valve must be fitted in a readily accessible position adjacent to the shower to facilitate maintenance of the shower. DO NOT use a valve with a loose washer plate (jumper) as this can lead to a build up of static pressure.
Page 9
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: Electrical The electrical installation must comply with BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant building regulations, or any particular regulation or practice specified by the local electricity supply company. Ensure that all circuit protection devices, switches and cabling is adequate for the rated current of the shower and that the rating of the electricity supply company fuse and the consumer unit are adequate for the additional demand.
INSTALLATION Replacing an Existing Shower 45 mm 170 mm 170 mm 40 mm Terminal Block 309 mm 300 mm Inlet Water Inlet Water 150 mm Supply Supply 150 mm 212 mm 50 mm 220 mm 55 mm Check the existing installation is positioned according to the dimensions specified in the diagram above.
Page 11
Isolate the electrical and water Retaining Screws supplies. Disconnect and remove the old shower from the wall. Remove the cover and service tunnels from the Mira Sport Multi-fit. Keep the retaining Cover Service Retaining Tunnel screws (x3) for later use. Screw Position the Mira Move shower on the existing pipework.
Page 13
Adjustment For Right Hand Entry Electrical Supply Isolate the electrical and water supplies. Unscrew the terminal block retaining screw. Carefully lift the terminal block from its location on the left of the case and remove the retaining screw. Taking care not to damage the wires, reposition the terminal block and the splashguard to the location on the right hand side of...
Page 14
Connecting Electricity and Water Supplies Flush the inlet water pipe through to clear any debris. Inlet Connector Connect the inlet supply pipe to the Compression Nut shower inlet using a 1/2” BSP nipple Olive with compression nuts and olives (as shown) or a push-fit connector. 1/2’’...
Page 15
If necessary, fit an earth bonding Retaining Screws clamp to the supply pipe. Make sure the bonding complies with the relevant regulations in force at the time of installation. Turn on the water supply and check for any leaks. Refit the service tunnel and the required insert.
Page 16
COMMISSIONING Caution! If you are unsure how electric showers work, please read the Operation section before continuing. Turn the temperature control fully anticlockwise to cold and the heater control to “LOW”. Switch on the electrical supply at the double pole switch. The power light will indicate electricity is being supplied to the shower.
Page 17
The Effect of Seasonal Changes * * * For a cold shower select Low. For a summer warm shower select Eco. For a winter warm shower select High. During extremes of mains water supply temperature, adjust heater setting to obtain a better showering temperature.
DO NOT connect the outlet of the shower to any tap, control valve, trigger handset or showerhead other than those specified for use with this shower. Only Kohler Mira recommended accessories should be used.
Page 19
Operating Instructions Turn the shower on Switch on the electrical supply at the double pole switch. The power light is illuminated. Turn the shower on by pressing the start/stop button. Select heater setting Turn the heater control to High. Allow 15-20 seconds for warm water to reach the handset.
FAULT DIAGNOSIS The troubleshooting information tabled below gives you details on probable causes and remedies should difficulties be encountered whilst the shower is in operation. Warning! There are no user serviceable components beneath the cover of the appliance. ONLY A COMPETENT TRADESPERSON SHOULD REMOVE THE FRONT COVER! Malfunction Probable Cause Possible Remedy...
Page 21
The handset sprayplate is Remove and clean the handset water temperature. blocked. sprayplate (see User Maintenance). If the fault persists, contact Kohler Mira Customer Services. Clean the handset sprayplate (see User No water or very low The handset sprayplate and/or flow rate.
Page 22
Clean the inlet filter (see Servicing). The inlet filter is blocked. Renew the fuse or reset the MCB/RCD. The fuse is blown or the If the fault persists, contact Kohler Mira MCB/RCD has been tripped, Customer Services to help diagnose indicating a possible electrical the fault and replace any parts as fault;...
USER MAINTENANCE WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY: There are no user serviceable DO NOT use the showerhead to parts inside the shower. Only clean the shower. qualified, competent personnel If the shower is not to be used for should remove the front cover, a long period, the electrical supply mains connections are exposed...
Page 24
SERVICING WARNING There are no user serviceable parts inside the shower. Servicing of the shower must only be carried out by qualified, competent personnel following the instructions provided in this guide and those provided with any spare part. Before replacing any parts, ensure that the underlying cause of the malfunction has been resolved.
Need help?
Do you have a question about the Mira Move 8.5 and is the answer not in the manual?
Questions and answers