Conversion from LP Gas to
Natural Gas
Orifice Change and the Installation of the NG regulator
1.
Turn off the main gas supply valve.
2.
Disconnect 20 lb LP gas fuel tank (if present).
3.
Turn off burner control valve.
4.
Use screwdriver to remove screw holding the corrugated
pipe connector to the enclosure.
5.
Use adjustable wrench to remove hose and regulator from
corrugated pipe connector.
6.
Remove side burner cooking grid and burner cover.
7.
Remove igniter junction wire from electronic igniter module.
8.
Remove 3 screws off the front baffle.
9.
Lift up front baffle away from burner.
10. Use a 6 mm socket and wrench or 6 mm nut driver to
remove the LP gas orifice from the end of gas valve.
11. Use a 6 mm socket and wrench or 6 mm nut driver to
install NG gas orifice to the end of gas valve.
19