Holmes HAP702-NTU-1 - Allergen Remover Performance Plus Air Purifier Manual

Holmes HAP702-NTU-1 - Allergen Remover Performance Plus Air Purifier Manual

Advertisement

Holmes HAP702-NTU-1 - Allergen Remover Performance Plus Air Purifier Manual

POWER CORD INSTRUCTIONS

  • The length of cord used on this appliance was selected to reduce tangling or tripping hazards.
  • If a longer cord is necessary, an approved extension cord may be used. The electrical rating of the extension cord must be equal to or greater than the electrical rating of the air purifier (see rating label marked on bottom of the product).
  • Care must be taken to arrange the extension cord so that it will not drape over the countertop or tabletop where it can be pulled on by children or accidentally tripped over.

GET TO KNOW YOUR DEVICE

This unit is compatible with all Aer1 Filters. This allows you to choose the filter that is just right for you. Below is information on each filter:
TOTAL AIR - Advanced Dust Eliminating Technology
ODOR ELIMINATOR - 10x the odor fighting power
ALLERGEN REMOVER - True HEPA technology improves air quality for allergy sufferers
ALLERGEN PERFORMANCE PLUS - True HEPA technology improves air quality for allergy sufferers.
SMOKE GRABBER - 99% effective at removing smoke from the air steam (*as small as 0.3 microns from air passing through the filter)

FEATURES

IONIZER

This appliance has an optional ionizer feature which, when turned on, releases negative ions into outgoing filtered air to help the air purification process.

What Are Ions?
Ions are tiny particles that carry a positive or negative charge. They exist naturally around us: in the air, water, and ground. Both positive and negative ions are colorless, odorless, and harmless.

How Does The Ionizer Work?
Negative ions help air purification by attaching themselves to very small airborne particles in the room. These particles take on a negative charge and may join with positively charged particles such as dust, pollen, smoke, and pet dander to form larger particles. These larger particles are then more easily captured by the filter system.

Important Notes:
Your ionizer may produce an occasional popping or cracking sound. This is normal and occurs when a small buildup of ions is discharged.
After extended use, you may notice dust around the grills or front panel. This is caused by negative ions exiting the air outlet, evidence of the ionizer's air cleaning effectiveness. You can remove the dust with a soft brush or clean, damp cloth.
Larger particles may be attracted to positively charged surfaces throughout the home, like walls or floors.

  • This may occur more frequently when the filter is nearing the end of its useful product life and unable to capture as many charged particles.
  • Excessive amounts of pet dander, dust, or smoke may decrease the life expectancy of the filter and interfere with the ionization process. To help prevent particles from attracting to surfaces throughout your home:
  • You may want to run the ionizer less often.
  • Check the condition of the filter more frequently.


The ionizer in this appliance produces less ozone than the UL established limits of 50ppb. However, in high concentrations, ozone can be harmful to birds and small pets. To prevent ozone buildup, we suggest using the ionizer in well ventilated areas with the air purifier fan on.

HIGH, MEDIUM AND LOW SPEED SETTINGS

For optimum air filtration, operate your Holmes air purifier continuously on the MEDIUM (Med) setting. Its rugged motor has been designed to give many years of use. For quieter operation (such as in a bedroom), select the LOW (Lo) setting. When high levels of air pollution are present, select the HIGH (Hi) setting to quickly circulate and filter the room air.

FILTER CHECK INDICATOR

Your Holmes Air Purifier includes Aer1 Allergen Performance Plus Filter, specially designed to improve air quality for allergy sufferers!! The Aer1 Allergen Performance Plus filter last for 12 months. See back panel for other filter options.

The Filter Check Indicator light is designed to remind you to check and change your filter every 11 months. To reset the Filter Check Indicator, press and hold the Filter Reset Button for 3 seconds only under working mode.

BEFORE USE

Part Names

  1. Filter Reset Button/Light
  2. Ionizer Button/Light
  3. Speed Control Knob
  4. Control Panel
  5. Filtered Air Outlet
  6. Aer1 Filter
  7. Carbon Filter
  8. Washable Foam Pre-Filter
  9. Air Inlet Grill
  1. Carefully unpack your Air Purifier. Select a firm level place where there are no obstructions to the air inlet or filtered air outlet.
  2. Remove the air inlet grill and check if the filter is covered by a plastic bag. If it is, remove plastic bag before use.
  3. The carbon filter is packed in a plastic bag in the box. Remove plastic bag, use the provided Velcro to attach the carbon filter onto the Aer1 filter. Then, place all filters back into the unit, and reinstall the air inlet grill (see Fig. 1).
  4. DO NOT POINT FILTERED AIR OUTLET TOWARDS WALL.

OPERATING INSTRUCTIONS

  1. Plug into a 120V AC electrical outlet.
  2. Select the desired operating speed; HIGH (Hi), MEDIUM (Med), LOW (Lo), by turning Speed Control Knob to the appropriate setting. For optimum air filtration, it is recommended to operate the air purifier continuously. Its rugged motor has been designed to give many years of use.
  3. To release negative ions into the filtered air, press the ionizer button ( ) to ON and the button will illuminate in blue.
    NOTE: The ionizer will not work unless the unit is running.

CLEANING/MAINTENANCE INSTRUCTIONS

  1. Turn the air purifier off and unplug it before cleaning.
  2. The outside of the air purifier can be cleaned with a soft, clean dampened cloth.
  3. The air inlet grill (reference Fig. 1) can be removed and washed in warm soapy water (not dishwasher safe). Dry before replacing in the unit.
  4. The filtered air outlet can be cleaned of dust with a small, soft brush.
  5. If you wish to clean the inside of the air purifier, please only use a dry, soft cloth to wipe it down.

    Do not allow moisture to come in contact with the main housing of the air purifier.

FILTER REPLACEMENT INSTRUCTIONS

  • DO NOT attempt to wash and re-use the Aer1 Filters.
  • If the filters are enclosed in plastic bags, remove them before use.

NOTE: Every few weeks, check the condition of filter. Filter life will vary, depending on air quality and usage (see below). Under normal conditions of continuous use, the Aer1 Total Air, Odor and Smoke Filter will last 4 months while the Allergen and Allergen Performance Plus Filter will last 12 months. Check the condition of the Carbon Filter for every 3-4 months and replace if needed. Carbon filter needs to be replaced every 60-90 days.
After approximately 11 months of operation, the Filter Check Indicator will light up to alert you to service the filters.

  • This Filter Check indicator is to remind you to wash the foam pre-filter and replace your Aer1 Filter.

To replace your filter:

  1. Turn off and unplug the air purifier.
  2. Open the air inlet grill and examine the black foam prefilter. Remove any dust or lint and wash in warm soapy water. Rinse, drip dry and place back into grill inlet.
  3. Remove the used Aer1 filter from the unit by pulling it gently towards you and discard it. DO NOT attempt to clean the Aer1 filter.
  4. To replace the carbon filter, simply remove the old carbon filter with the Velcro, and insert a new carbon filter in place after first removing the plastic bag. Using the new Velcro provided with the carbon filter to attach the new carbon filter onto the new Aer1 filter.
  5. Install the new Aer1 filter into the unit.
  6. Align the clip on the side of Aer1 filter with rails on the inside of the purifier unit. Gently slide the filter onto the rail.
  7. Replace air inlet grill.
  8. To reset the Filter Check Indicator, press and hold the Filter Reset Button for 3 seconds only under working mode when unit is powered on.

NOTE: Every time you power on the air purifier by selecting any speed setting, the Filter Check checks the current usage of the filter. If the filter timer has not reached the filter life, the indicator light will go off. If not, the indicator will remain lit until filter have been replaced and Filter Check Indicator ( ) has been reset (see instructions above).

Filters can be purchased at a retailer near you, online at www.holmesproducts.com.

Air Purifier Model Number Filter Quantity Needed Compatible with all filter models below Filter Description
HAP702 1 HAPF30AT*
HAPF30AO
HAPF30AS
HAPF300AH
HAPF300AP (D filter)
HAPF30 (A filter)
aer1 Total Air Filter
aer1 Odor Filter
aer1 Smoke Grabber Filter
aer1 Allergen Remover Filter
aer1 Allergen Performance Plus "D" Filter
Holmes "A" Filter
1 BHOR31 Carbon Filter

*HAPF30AT Come with the original box "HAPF30AT (equipped with this unit)

TROUBLESHOOTING

TROUBLESHOOTING
Problem Solution
  • Unit will not operate

Check if unit is properly plugged in and outlet is energized.
Make sure unit turned ON.
Make sure filters are properly installed and rear grill is seated correctly.
  • Decreased air flow

Make sure nothing is blocking air inlet and filtered air outlets.
Check condition of the filters and replace if necessary.
Check filter to remove any plastic wrapping/packaging.
Ensure carbon filter is changed every 60-90 days.
  • Excessive Noise

Make sure parts are firmly positioned in place.
Open the air inlet grill and make sure that any plastic packaging was removed from the filters, if applicable.
  • The filter check indicator will not reset

Check condition of the filters and replace if necessary.
Press and hold the Filter Reset Button for 3 seconds under power on condition.

LEARNING MORE

For a wealth of information about your air purifier and other Holmes products, visit our website at www.holmesproducts.com or call 1-800-546-5637. For inquiries regarding recycling and proper disposal of this product, please contact your local waste management facility.

AER1 FILTER SERIES

Congratulations! Your new air purifier is equipped with the Aer1 Performance Plus Filter.

Filter Type Technology Consumer Benefit
Total Air 99% HEPA-Type technology.
Infused with baking soda.
Ideal for dust reduction. Delivers 30% better air quality.
Odor Eliminator 10 times the odor fighting power.
Contains baking soda, carbon and zeolite for odor control.
Ideal for eliminating odors from pets, tobacco smoke and cooking fumes.
Allergen Remover 99.97% True HEPA technology.
Removes up to 99.97% of particles as small as 0.3 microns passing through the filter such as pollen, dust, mold and dander.
Ideal for allergy sufferers.
Allergen Performance Plus 99.99% True HEPA technology.
Helps remove up to 99.99% of particles as small as 0.3 microns passing through the filter such as pollen, dust, mold and dander.
Ideal for allergy sufferers.
Smoke Grabber HEPA-type filtration.
Triple layer protection specially formulated with Baking Soda, Carbon and Zeolite.
Removes up to 99% of smoke and pollutants as small as 0.3 microns from air passing through the filters.
Ideal for reducing smoke and odors from smoke and VOC's.

© 2017 Sunbeam Products, Inc. doing business as Jarden Consumer Solutions. All Rights Reserved.
Distributed by Sunbeam Products, Inc. doing business as Jarden Consumer Solutions, Boca Raton, Florida 33431.
Sunbeam Products, Inc. is a subsidiary of Newell Brands Inc. (NYSE: NWL).

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Holmes HAP702-NTU-1 - Allergen Remover Performance Plus Air Purifier Manual

Advertisement

Need help?

Need help?

Do you have a question about the HAP702-NTU-1 and is the answer not in the manual?

Questions and answers

Table of Contents