Harmony BACKGROUND

First, thank you for choosing a Holmes Harmony® Air Purifier. The Harmony® Air Purifier was created because consumers, like you, provided a lot of feedback about what you wanted in an air purifier. With the features consumers want in mind, we worked with sound experts and engineers to make the unit quieter and smaller, with more advanced technologies. We designed a patented modular filter system for easier filter replacement. The result is an air purifier that is in harmony with your environment--it cleans your air and fits your life.

FEATURES

Dual Position- the air purifier can stand upright or lie on its side. Also designed to fit with its back flush against the wall. When positioning the unit, please be sure the air inlet grill, filters and air outlet are not blocked to ensure maximum airflow.

Equipped with GE motor for quieter performance and the added durability necessary for continuous use.

Filter Life Indicator- The Filter Life Indicator uses a series of lights to give you an indication of the remaining filter life. When the filters are new and in good condition, the top light will be illuminated green. As the filter life progresses, the Filter Life Indicator will move to yellow. At this point, the carbon and HEPA filters should be checked. When the Filter Life Indicator light is red, it is time to change the filters. (On the HAP675RC, there are 2 filter indicator lights. The first light will be in amber color when the filter is in new or good condition. Over a period of time, the filter performance will begin to decrease. At this point, the second light will become red.)

Remote Control/Push Button Controls (For HAP675RC only)
This unit offers a remote control for convenient operation from anywhere within your room. The push button control area also allows for easy operation. The HAP675RC can be controlled/operated by either the remote control handset or the manual push buttons on the unit. The remote control has 5 buttons – 4 speeds settings and power off. The remote control requires 2 AAA batteries.

BATTERY WARNING:

  • DO NOT mix old and new batteries.
  • DO NOT mix alkaline, standard (carbon-zinc), or rechargeable (nickel-cadmium) batteries.

PRE-OPERATING INSTRUCTIONS

NOTE: The door should not be opened when the unit is on its side.

  1. After removing the unit from the box, take the plastic coveringoff the unit and properly dispose of it.
  2. Place unit with air intake grill pointing up.
  3. Open the door of the air purifier.
  4. The carbon filters, which are packed in a plastic bag in the box, should be removed from plastic bag and then placed on each of the HEPA filters. The plastic tabs on the HEPA filter will hold the carbon in place (see Figure 1).
    Parts and Description - Part 1
    1. HEPA FILTER
    2. CARBON FILTER
  5. Close the air purifier door by pushing firmly against the righthand side of the door.

OPERATING INSTRUCTIONS

  1. Select location where air intake grill and filtered air outlet arenot obstructed.
  2. Plug into a 120V AC electrical outlet.
  3. The air purifier is now ready for use. Set the air purifier to the desired speed setting; High (IIII), Medium (III), Low (II) or Sleep (I) by turning the speed control knob. (On the HAP675RC, you will need to press the ON/OFF button to turn the unit on. ON will automatically cycle to the highest setting. Use the speed button to set the desired speed: High (IIII), Medium (III), Low (II) or Sleep (I).)

For continuous use, it's recommended to operate the air purifier at the MEDIUM setting. For quieter operation or use in a bedroom, select the LOW setting. When high levels of air pollution are present, select the HIGH setting to quickly circulate and filter the room air.

FILTER REPLACEMENT INSTRUCTIONS

  1. On average, HEPA filters need to be replaced every 12-18 months. Carbon filters need to be replaced every 3-6 months. Filter life will vary depending on air quality and usage.
  2. Turn off and unplug the air purifier before attempting to replacethe filters.
  3. Remove each of the filters from the unit by pulling gently towardsyou.
  4. To replace the carbon filter, simply remove the old carbon filterand insert a new carbon in its place, using the plastic tabs as a guideline (see Figure 1).
  5. To replace the HEPA filter, discard the old HEPA filters. DO NOTattempt to clean. Put the carbon filter back on the new HEPA filter. Insert the new HAPF600 HEPA filter into the unit, by sliding it onto the hang tabs. (see Figure 2)
    Parts and Description - Part 2
    1. HANG TABS
  6. After replacing the HEPA filters, RESET the Filter Life Indicator byinserting a small object (such as a pin or paper clip) into the hole below the red filter change light marked RESET.

Parts and Description - Part 3

  1. AIR INTAKE GRILL
  2. FILTERED AIR OUTLET
  3. SPEED CONTROL KNOBS
  4. FILTER LIFE INDICATOR
  5. RESET BUTTON
  6. POWER CORD (not shown)

REPLACEMENT FILTERS ARE AS FOLLOWS:
HAPF600 HEPA Filter
HAPF600D HEPA Filter (2 pack)
HAPF60 Carbon Filter
These filters can be purchased at a retailer near you or by calling 1-800-5-HOLMES.

NOTE: Carbon and HEPA Filters are not washable and should be replaced at the recommended intervals.

CLEANING/MAINTENANCE INSTRUCTIONS

  1. Turn the air purifier off and unplug it before cleaning.
  2. The outside of the air purifier can be cleaned with a soft, clean damp cloth.
  3. The filtered air outlet on the top of the unit can be cleaned of dust with a small, soft brush.
  4. If you wish to clean the inside of the air purifier, please remove filters and only use a dry, soft cloth to wipe it down.
  5. DO NOT wash filters.


Do not allow moisture to come in contact with the main housing of the air purifier.

TROUBLESHOOTING

PROBLEM SOLUTION

Unit will not operate

  • Check to make sure the unit is plugged in.
  • If the door is ajar the unit will not operate. Make sure the filters are properly installed and firmly close the door.
  • Check to make sure the unit is on by turning the knob or pressing the speed button.

Decreased air flow

  • If the Filter Life Indicator is red, the HEPA filters need to be changed.
  • If the filters have not been changed in a year or more, change the HEPA filters.
  • Check to ensure nothing is blocking air inlet and filtered air outlet.
  • Ensure carbon filters are changed every 3-6 months.

Holmes® and the Holmes® logo, Harmony®, are registered trademarks of The Holmes Group, Inc. or its subsidiaries.
GE® is a registered trademark of The General Electric Company.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Holmes HAP615, HAP625, HAP650, HAP675, HAP675RC - 99.97% HEPA Air Purifier Manual

Advertisement

Need help?

Need help?

Do you have a question about the HAP615 and is the answer not in the manual?

Questions and answers

Table of Contents