(SAVE THESE INSTRUCTIONS)
This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS.
To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.)
To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.
Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.
Do not plug the UPS input into its own output.
Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.
Do not attach a power strip or surge suppressor to the UPS.
If the UPS is with metal chassis, for safety purpose, grounding is a must during UPS installation in order to reduce leakage current below 3.5mA.Attention hazardous through electric shock. Also with disconnection of this unit from the mains, hazardous voltage still may be accessible through supply from battery. The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary.
Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
When replacing the batteries, use the same number and type of batteries.
Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
A battery can present a risk of electric shock and high short circuit current. The following precaution should be observed before replacing batteries:
Inspect the UPS upon receipt. The box should contain the following:
The Value1200ELCD/1500ELCD/2200ELCD provides automatic voltage regulation for inconsistent utility power, and provides battery backup during power outages. The Value1200ELCD/1500ELCD/2200ELCD ensures consistent power to your computer system and its included software will automatically save your open files and shut down your computer system during a utility power loss.
LCD Indication
Line mode
"V": Illuminated, "X": Not Illuminated, "--": Either
Battery mode
"V": Illuminated, "X": Not Illuminated, "--": Either
CyberPower's Green Commitment
CyberPower is dedicated to the development of green products, and has adopted Green practices throughout its business, including: membership in Climate Savers Computing Initiative (CSCI), accordance with the Restriction on Hazardous Substances (RoHS), Waste Electrical and Electronic Equipment (WEEE) protocols, as well as ISO 14001 and IECQ QC080000. CyberPower pledges to provide the advanced energy solution for the environment and become a leading eco-friendly organization in the UPS industry.
Reduce Energy Cost with GreenPower UPSTM Technology
CyberPower's goal is not only to provide eco-friendly products but also to bring the best value for consumers. The advanced energy-saving design improves the operating efficiency and eliminates waste energy consumption. As a result, consumers will enjoy significant energy cost savings with the adoption of GreenPower UPSTM technology.
Problem | Possible Cause | Solution |
The UPS does not perform expected runtime | Batteries are not fully charged. | Recharge the battery by leaving the UPS plugged in. |
Battery is slightly worn out. | Contact CyberPower Systems Technical Support. | |
The UPS will not turn on | The on/off switch is designed to prevent damage by rapidly turning it off and on. | Turn the UPS off. Wait 10 seconds and then turn the UPS on. |
The unit is not connected to an AC outlet. | The unit must be connected to a 220-240V 50/60Hz outlet. | |
The battery is worn out. | Contact CyberPower Systems Technical Support. | |
Mechanical problem. | Contact CyberPower Systems Technical Support. | |
Outlets do not provide power to equipment | Circuit breaker is tripped due to overload | Turn the UPS off and unplug at least one piece connected equipment. Unplug the power cord of the UPS then press the circuit breaker knob. |
Batteries are discharged | Allow the unit to recharge for at least 4 hours. | |
Unit has been damaged by a surge or spike. | Contact CyberPower Systems Technical Support. | |
PowerPanel® Personal Edition is inactive | The serial/USB cable is not connected. | Connect the serial/USB cable to the UPS unit and an open serial port on the back of the computer. You must use the cable that came with the unit. |
The unit is not providing battery power. | Shutdown your computer and turn the UPS off. Wait 10 seconds and turn the UPS back on. This should reset the unit. |
For more information, visit www.cpsww.com
All rights reserved. Reproduction without permission is prohibited.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download CyberPower Value1200ELCD, Value2200ELCD, Value1500ELCD - UPS Manual
Advertisement
Need help?
Do you have a question about the Value1200ELCD and is the answer not in the manual?
Questions and answers