5-64 Installing and Using Utilities
Procedure in the Server Maintenance Utility
Start
1.
Select the target component by using the Server Maintenance Utility.
2.
Check the current state of the target component with the LEDs.
3.
Click the [Up] button of the target component.
A certain time is required for the start.
The start result can be confirmed by the LEDs on the target component. The result of the
start operation is registered in the event log.
CHECK:
When starting a stopped IO module, diagnostics of the CPU/IO modules are
automatically performed. The IO module is started after the diagnostics.
Stop
Stop before replacing components.
1.
Select the target component by using the Server Maintenance Utility.
2.
Check the current state of the target component with the LEDs.
3.
Click the [Down] button of the target component.
A certain time is required for the start.
The start result can be confirmed by the LEDs on the target component. The result of the
start operation is registered in the event log.
CHECK:
When stopping IO module, check that the status of Ethernet is "Duplex" on Server
Maintenance Utility. Do not stop the IO module especially when LAN is connected only
to the IO module on that side.

Advertisement