Professional analog&digital catv "qam-dvb-c" palm-top analyzer (56 pages)
Summary of Contents for Rover HD TAB 700
Page 1
TAB 700 TAB 700 T A B 7 0 0 T A B 7 0 0 & & Plus Plus TAB 700 TAB 700 & & P l u s P l u s T A B 7 0 0 T A B 7 0 0 TFT 16:10 TFT 16:10...
Page 2
Get to know your tAB 700 Front panel __________________________________ nB: The MENU (functions and Graphics) an be change without advise. • poWEr To turn on To turn off press the press and hold ‘HOME’ key. the ‘HOME’ key • WHEEL Use the wheel to navigate across the screen and adjust the values Select a menu Rotate to select...
SIDE pAnELS ____________________________________________________ • LEFT SIDE • rIGHT SIDE • Top SIDE lAN Eternet RJ45 Analog video IN (CvBS) (only for Plus version) USB B SW upgrades Remote Power Supply switch DC at RF IN ON/OFF USB A memory stick IF/RF IN “F”...
Page 4
Multi-purpose BAG Make work easier by taking advantage of your multi-purpose bag. Work safely and without restrictions with both hands free. Connect the shoulder strap to the two hooks at the corners of the bag (top left and bottom right), so you can hang your meter around your neck leaving both hands free.
HoMe And nAViGAtion ‘HoME’ ScrEEn ________________________________________________ Press the ‘HOME’ key to go to the home screen, then rotate the wheel to navigate on ‘SAT’, ‘Tv’ or ‘CATv’ icons and press the wheel to select the measurement mode required. Press the ‘HOME’ key at any time to return to the home screen nAvIGATIon ____________________________________________________...
Page 6
How to select from the menus and change a value using the drop down menus: • Rotate the wheel and select the menu required (fig. 1) • Keep the wheel pressed for 2” to visualized the drop down menu (fig. 2) •...
Page 7
fig. 3 fig. 5 fig. 4 nAvIGATIon uSInG MIXED coMMAnDS: MEcHAnIcAL & ToucH • Touch a value in the menu (fig. 1) • Rotate the wheel to adjust the value (fig. 3) or touch the value required (fig.2) • Press the wheel and confirm the selection (fig.3) or touch the monitor outside the drop down menu (fig.3) Select from the menus and adjust the value using the drop down menu: •...
Page 8
fig. 2 fig. 3 Example of SATEllITE transponder selection (TP/TS): fig. 1 fig. 2 fig. 3...
Page 9
Select the frequency and set the value using the numerical keyboard: • Touch FREQ to show the menu “INSERT FREQ” (fig. 1) • Touch the numbers to digit the required frequency value (fig. 2) • Finally touch enter and confirm the selection (fig. 3) Example of manual frequency selection (FREQ): fig.
Page 10
confiGurAtion volume selection is immediately active, press “ENTER” for the Display configuration and other important settings vIDEo In ________________________________________________________ “vIDEO IN” (connector 7): Select “EXT” to visualize an external video source. BATTEry SAvInG AnD TIMEr oFF ________________________ Settings for battery save mode. Choose “BATTERY SAvING”...
ToucHScrEEn cALIBrATIon _____________________________ if the touchscreen does not respond to the commands, it may be necessary to calibrate: Touch “CONFIGURATION MENU” Touch “METER” from the volume window; then “CAlIBRATE TOUCHSCREEN”; Touch the center of the squares that appear in the corners of the screen, repeat four times for every squares.
Page 12
DIScovEry _____________________________________________________ Identifies the modulation of a tuned Tv channel in the Tv master PlAN Touch the “CONFIGURATION MENU” in the vOlUME window. Tv MoDE cATv (cABLE) MoDE ____________________ ____ Touch “Tv” and then “DISCOvERY” Touch “CATv” and then “DISCOvERY” and set the identification mode: and set the identification mode: - TERR ONlY...
Page 13
c/n TypE _____________________________________________________________ Set the measurement mode of the carrier noise ratio “C/N” (in band-out band). Touch ‘CONFIGURATION MENU’ Touch “Tv” then “C/N TYPE”. from the volume screen. C/N measurement mode “IN BAND”: C/N measurement mode “OUTSIDE THE BAND”: the signal/noise ratio is measured The signal/noise ratio is measured between the between the signal level of the video signal level of the video carrier...
Page 14
screen sHot The “SCREEN SHOT” function allows you to directly save the TFT monitor screens in an external memory. • Connect an external memory source (not provided) to the USB A socket. • Set the instrument on the screen to be saved: Spectrum, Measurements, Constellation, Echoes etc.
Page 15
sAt MeAsureMents Press the “HOME” key. Touch “SAT”, and then “PlAN” Touch directly the desided satellite, or use or use the encoder to obtain the the encoder. At the end touch “MEAS” to Satellite list. make the measure or “SPECT” for visualize the spectrum.
DvB-S, DvB-S2 SAT MEASurES ________________________ Press the “HOME” key. Touch “SAT” and then “MEAS & PICT” Main measures and image. or use the encoder. rELATED FuncTIonS _________________________________________ Press repeatedly to navigate into Press to enter in SAT measures screens: Measures, the spectrum.
Page 17
vISuALIzE nIT ___________________________________________________ Touch “MENU&?” from the “MAIN Touch “vISUAlIzE NIT”. MEASUREMENTS & PICTURES”. Example 1: “NIT INFO vISUAlIzATION” referring to an HOTBIRD 13° East transponder noTE: The function vISUAlIzE NIT is available also in Tv & CATv mode...
cHAnnEL MonITor __________________________________________ The weekly application of SW CHANNEl MONITOR allow you to control and register the trend of the main parameters of a digital signal over time (from 30 minutes to one week): Tv, CATv & SAT. This application is indicated to resolv the reception problems which occur occasionally, it allow you also to measure, memorize and visualize (local or in remote) the digital signals parameters tested: DvB-S/T/C = Power, MER, ERROR, bBer, aBer;...
Page 19
SpEcTruM AnALyzEr ____________________________________ Touch “SAT” and then “SPECT”or use the Press the “HOME” key. encoder. SAT SPAN FUll SAT Spectrum Press again the SPECT key to activate the (from 930 to 2250 MHz). “MAX HOlD” function. Touch “SPAN” and rotate the encoder to select the SPAN value desired: 10-20-50-100-200-500-FUll SAT-FUll EXT Example 1: Example 2:...
Page 20
SAT EXpErT ___________________________________________________________ The SATEXPERT SW function (guided satellite tracking function), is a valuable aid for a fast satellite antenna pointing to a wanted satellite. Through text messages, which appear from time to time on the screen, the measuring instrument will indicate in which direction to move the satellite dish, to the east or to the west, until you reach the wanted satellite.
Page 21
EXAMpLE 3: SAT to be found detected The pointed Salellite is not the correct one. The lower part of the display shows the following information: EuTE7 < Go EAST (move the satellite dish EAST). IMporTAnT: The text messages that from time to time will appear on the screen of the instrument when moving the satellite dish to east or west, are bounded to the diameter of the used antenna: 60-80-90 cm etc.
Page 22
conSTELLATIon AnALySIS _______________________________ Press the “HOME” key. Touch “SAT” and then “CONST” or use the encoder. Example 1: Example 2: QPSK constellation. 8PSK constellation. Touch “FUll and select the zone of constellation to elnarge. rELATED FuncTIonS _________________________________________ Press repeatedly to navigate into Press to enter in SAT measures screens: Measures, the spectrum.
SAT FInDEr ________________________________________________ The SAT FINDER function allow you to check the quality of 4 transponders simultaneity and to check the operation of the 4 lNB polarities. Press the “HOME” key. Touch “SAT” and then “SAT FINDER” or use the encoder. Satellite locked.
Page 24
Az/EL poInTInG DATA _____________________________________ Press “HOME” key. Touch “SAT” and then “Az/El”. Calculation of the pointing data: - Touch “SAT ORBIT” and set up the orbit position of the desired satellite, for example 13,0 EAST. - Touch “COUNTRY” and select your Nation, for example Italy. - Touch “CITY”...
Page 25
MEASurES WITH Scr LnB/MuLTISWITcH __________ Touch the “HOME” key. Touch “SAT” and then “SCR DCSS” or use the encoder. - Touch “lNB TYPE” and select the installed SCR measures. lNB/multiswitch model (see NOTE). - Touch “USER” and select the user’s number to test (user 1-4).
Page 26
LnB/MuLTISWITcH dcSS MEASurES ________________ Press the “HOME” key. Touch “SAT” and then “SCR DCSS” or use the encoder. - Touch “lNB TYPE” and select the installed dCSS measures. lNB/multiswitch model (see NOTE). - Touch “USER” and select the user’s number to test (user 5-16). - Press “SPECT”...
Page 27
IMAGES vISuALIzATIon & SErvIcE cHoIcE __________ Press “HOME” key. Touch “SAT” and then“MPEG” or use the encoder. Touch directly the RADIO/Tv desired service or use the encoder. or touch “vpid-Apid” in Measure screen. Images and MPEG service list. RADIO & Tv service selection. Touch the image to enlarge.
Page 28
tV MeAsure Press the “HOME” key. Touch “Tv” and then “PlAN” Touch directly the desided canalization or use the encoder to access or use the encoder. At the end touch at the Tv canalizations list. “MEAS” to make the measure or “SPECT” for visualize the spectrum.
Page 29
DIGITAL Tv MEASurEMEnT DISpLAyS DvB-T & DvB-T2 M-pLp Press the “HOME” key. Touch “Tv” and then “MEAS & PICT” Main menu and image. or use the encoder. rELATED FuncTIonS _________________________________________ Press repeatedly to navigate into Tv measures screens: Press to enter in Measures, Constellation, Echoes the spectrum.
Page 30
DvB-T2 SIGnAL: pLp SELEcTIon ________________________________ Touch “MENU” from Touch “PlP #” and select the desired PlP MAIN MEASURES & IMAGES screen. (transport Stream) DvB-T2 SIGnAL: proFILE SELEcTIon _________________________ Touch “MENU” from Touch “PROFIlE” MAIN MEASURES & IMAGES screen. and select the desired profile: “Basic”...
Page 31
SpEcTruM AnALyzEr ____________________________________ Touch “Tv” and then “SPECT” Press the “HOME” key. or use the encoder. Tv spectrum SPAN 50 MHz Press again te spectrum key to activate the “MAX HOlD” function. Touch “SPAN” and rotate the encoder to select the desired SPAN value: 1-2-5-7-10-20-50-100-200-500-FUll-UHF vHF Example 1: Example 2:...
Page 32
conSTELLATIon AnALySIS _______________________________ Press the “HOME” key. Touch “Tv” and the “CONST” or use the encoder. Example 1: Example 2: Constellation DvB-T. Constellation DvB-T2. Touch “FUll” and select the box of constellation to enlarge. rELATED FuncTIonS _________________________________________ Press repeatedly to navigate into Tv measures screens: Press to enter in Measures, Constellation, Echoes...
Page 33
MEr vS cArrIEr MEASurEMEnT _______________________ The MER vs CARRIER measure allow to make analysis of the trend MER for single COFDM carriers which make up a signal DvB-T or DvB-T2. Press the “HOME” key. Touch “Tv” and then “MER vs CARRIER” or use the encoder.
Page 34
Example 1: Example 2: MER vs CARRIER : visualization mode MER vs CARRIER : visualization mode “vIS. TYPE: REvERSE” & “PICTURE: FUll” “vIS. TYPE: NORMAl” & “PICTURE: CONTOURS”. Example 3: MER vs CARRIER: visualization mode “vIS. TYPE: NORMAl”, “PICTURE: FUll” & “START/STOP CARR from 3000 to 4000”.
Page 35
EcHoES AnALySIS __________________________________________ Press the “HOME” key. Touch “Tv” and then “ECHOES” or use the encoder. Touch “TYPE” and select the echoes visualization mode: DISTAncE or TIME Impulse response (echo). MIcroEcHoES vISuALIzATIon ________________________________ Touch “MENU”, than “TYPE” MicroEchoes visualization, touch the Marker and select “...
Page 36
Once again Rover Instruments is the fi rst company to supply meters for TV installers, that can measure up to 16 ECHOES and PRE-ECHOES in real time. ROVER meters allow you to see ECHOES, measure the power and the delay in uS and the distance of the interfering broadcaster in Km.
Page 37
IMAGES vISuALIzATIon & SErvIcE cHoIcE __________ Touch “Tv” and then“MPEG” Press “HOME” key. ou use the encoder. Touch directly the RADIO/Tv desired service or use the encoder. or touch “vpid-Apid” in Measure screen. Images and MPEG service list. RADIO & Tv service selection. Touch the image to enlarge.
cHAnnEL MonITor _______________________________________ The weekly application of SW CHANNEl MONITOR allow you to control and register the trend of the main parameters of a digital signal over time (from 30 minutes to one week): Tv, CATv & SAT. This application is indicated to resolv the reception problems which occur occasionally, it allow you also to measure, memorize and visualize (local or in remote) the digital signals parameters tested: DvB-S/T/C = Power, MER, ERROR, bBer, aBer;...
Page 39
fM MeAsure Press the “HOME” key. Touch “Tv” and then “PlAN” Touch directly the desided canalization or use the encoder to access or use the encoder. At the end touch at the Tv canalizations list. “MEAS” to make the measure or “SPECT” for visualize the spectrum.
Page 40
FM MEASurEMEnT _______________________________________ Press the “HOME” key. Touch “CHAN” and select the Touch “Tv” and then “MEAS & PICT” “FMl” channel or “FMH”. or use the encoder. Touch “FREQ” and type the desired Main menu. frequency value, then touch “ENTER”. rELATED FuncTIonS _________________________________________ Press to enter in...
Page 41
SpEcTruM AnALyzEr ____________________________________ Touch “Tv” and then “SPECT” Press the “HOME” key. or use the encoder. FM spectrum SPAN 20 MHz Touch “SPAN” and rotate the encoder to select the desired SPAN value: 1-2-5-7-10-20-50-100-200-500-FUll-UHF vHF Example: FM spectrum SPAN 2 MHz...
Page 42
CATV CATV cAtV MeAsures CATV CATV Press the “HOME” key. Touch “CATv” and then “PlAN” or use Touch directly the desided canalization the encoder to access at the CATv or use the encoder. At the end touch canalizations list. “MEAS” to make the measure or “SPECT” for visualize the spectrum.
Page 43
DIGITAL DvB-c & DvB-c2 MEASurES (opt.) _____ Press the “HOME” key. Touch “CATv” and then “MEAS & PICT” Main measures and image. or use the encoder. rELATED FuncTIonS _________________________________________ Press repeatedly to navigate Press to enter in the into CATv measures screens: spectrum.
Page 44
SpEcTruM AnALyzEr ____________________________________ Touch “CATv” and then “SPECT” Press the “HOME” key. or use the encoder. Press again te spectrum key to activate the CATv spectrum SPAN 50 MHz. “MAX HOlD” function. Touch “SPAN” and rotate the encoder to select the desired SPAN value: 1-2-5-7-10-20-50-100-200-500-FUll-UHF vHF Example 1: Example 2:...
Page 45
conSTELLATIon AnALySIS _______________________________ Press the “HOME” key. Touch “CATv” and then “CONST” or use the encoder. Example 1: Example 2: 64 QAM constellation. 256 QAM constellation. Touch “FUll” and select the box of constellation to enlarge. rELATED FuncTIonS _________________________________________ Press repeatedly to navigate Press to enter in into CATv measures screens: the spectrum.
Page 46
LEAKAGE ______________________________________________________ Press the “HOME” key. Touch “CATv” and then “lEAKAGE” or use the encoder. Set the desired parameters, leakage measures. at the end touch “START” to start the leakage measures.
Page 47
InGrESS _____________________________________________________ Press the “HOME” key. Touch “CATv” and then “lEAKAGE” or use the encoder. Ingress measures. Set the desired parameters, at the end touch “START” to start the Ingress measures.
Page 48
IMAGES vISuALIzATIon & SErvIcE cHoIcE __________ Touch “CATv” and then “MPEG” Press the “HOME” key. or use the encoder. Touch directly the RADIO/Tv desired service or use the encoder or touch “vpid-Apid” in Measure screen. Images and MPEG service list. RADIO &...
Page 49
cHAnnEL MonITor ________________________________________ The weekly application of SW CHANNEl MONITOR allow you to control and register the trend of the main parameters of a digital signal over time (from 30 minutes to one week): Tv, CATv & SAT. This application is indicated to resolv the reception problems which occur occasionally, it allow you also to measure, memorize and visualize (local or in remote) the digital signals parameters tested: DvB-S/T/C = Power, MER, ERROR, bBer, aBer;...
SPECT spectruM AnAlysis After selecting the desired Operation Mode, Tv, CATv or SAT, you can directly access the Spectrum Analyzer by touching the “SPECT” icon from the “HOME” menu or by pressing the “SPECT” button directly. SAT SpEcTruM _____________________________________________________ SPECT Press the “HOME”...
Page 51
OPTIC OPTIC opticAl MeAsureMents (opt.) The instrument in version PlUS, equipped with an internal optical converter, allows you to perform POWER and OPTICAl ATTENUATION measurements as well as perform RF measurements from optical inputs, decode services, and display Spectrum. opTIcAL poWEr & ATTEnuATIon MEASurES Press the “HOME”...
Page 52
opTIcAL InpuT rF MEASurES After selecting the desired Operation Mode, Touch “OPTIC” and then “MEAS & PICT” Tv, CATv or SAT, press the “HOME” key. or use the encoder. Example 1: Example 2: Main measures and image of a SAT signal. Main measures and image of a Tv signal.
Page 53
rF SpEcTruM ForM opTIc InGrESS After selecting the desired Operation Mode, Touch “OPTIC” and then “SPECT” Tv, CATv or SAT, press the “HOME” key. or use the encoder. SAT spectrum SPAN “Full SAT” SAT spectrum SPAN “Full EXT” (from 930 to 2250 MHz). (from 230 to 2610 MHz).
Page 54
BARSCAN BARSCAN BArscAn cHEcK ALL cHAnnELS LEvEL/poWEr BARSCAN BARSCAN Press the “HOME” key, then touch “BARSCAN”. In the Tv standard canalization the meter displays the level/power of all Tv channels. In AUTOMEMORY or MANUMEMORY PlAN the meter displays the memorized channels and distinguishes Analog and Digital signals using 2 different colours.
Page 55
MEMORY MEMORY MeMory: cHAnnEL pLAnS AnD LoG FILES ______ MEMORY MEMORY AuToMEMory (Tv) ___________________________________________ Press the “HOME” key. Touch “AUTOMEMORY tv” or use the encoder. Set the desired parameters: Touch “to FIlE N” and select the destination file “AUTO” where the search must be saved. Touch “DISCOvERY”...
Page 56
Search channels complete. Search channels in progress. Once the Automemory is completed, the “AUTO” plan is automatically selected.
Page 57
LoGGEr SAvE (Tv/cATv) ___________________________________ Press the “HOME” key. Touch “SPECIAl FUNCT” and then “SAvE DATAlOGGER”. Touch “SAvE DATAlOGGER” and set the DATA lOGGER run. parameters required. Touch “START SAvE” to create a new log file. note: if the MANU plan has mixed Tv and SAT programs, the “STOP&GO” function will assist when running a lOGGER asking to move the cable lead from a Tv to a SAT signal source.
Page 58
LoGGEr rEcALL (Tv/cATv) ________________________________ Touch “SPECIAl FUNCT” Press the “HOME” key. and then “RECAll DATAlOGGER”. Touch “RECAll DATAlOGGER” Example of saved measured in the log file. and Set the lOG file parameters. Touch the screen to browse through Touch “RECAll?” to see them. measurements.
Page 59
LoGGEr SAvE (SAT) __________________________________________ Press the “HOME” key. Touch “SPECIAl FUNCT” and then “SAvE DATAlOGGER” Touch “SAvE DATAlOGGER” and set the DATA lOGGER run. parameters required. Touch “START SAvE” to create a new log file. note: if the MANU plan has mixed Tv and SAT programs, the “STOP&GO” function will assist when running a lOGGER asking to move the cable lead from a Tv to a SAT signal source.
Page 60
LoGGEr rEcALL (SAT) _______________________________________ Press the “HOME” key. Touch “SPECIAl FUNCT” and then “RECAll DATAlOGGER”. Touch “RECAll DATAlOGGER” Example of saved measured in the log file. and Set the lOG file parameters. Touch the screen to browse through Touch “RECAll?” to see them. measurements.
Page 61
The instrument, equipped with “SW RIFlECTOMETER App”, allows you to check the correct impedance matching of a 75Ω distribution installation. Through the use of calibrated noise generator (for Example ROvER mod. CNG 90 STC/CNG 70 USB), if in a distribution installation there was an impedance mismatch, such as a cable short-...
Page 62
Touch “SPAN” and select the correct Touch “dB DIv” and select the correct visualization value. visualization value. Touch “vERT.POS” and select the correct Touch “MRK1.freq” then “MRK2.freq” and set visualization value. the marker frequencies in correspondence with the first and second minimum points. Example 1: Example 2: In the DISTANCE window, read...
Page 63
• leave the value set by the manufacturer: 0 MHz. connEcTIon DIAGrAM Distribution cable mod. ROvER mod. ROvER HD TAB 700 CNG 90 STC noTE: for more information about the “APP”s, contact your distributor or send an e-mail to: wecare@roverinstruments.com...
Page 64
BuzzEr & noISE MArGIn GrApH _____________________________ After selecting the Tv/CATv canalization and Touch “SPECIAl FUNCT”, the desired channel press the “HOME” key. and then touch “BUzz & NOIS MARGIN”. Buzzer & Graphic of the progress of the noise NOISE MARGIN of the Tv/CATv tuned channel according to time. high tones = the BEST Noise Margin level deep tones = the WORST noise margin level Noise Marg = real time noise margin...
Page 65
TEST InTErFErEnzE LTE ____________________________________________ Or press 2 time “BARSCAN” key. In Tv or CATv mode press the “HOME” key. Touch “SPECIAl FUNCT”, and then “lTE AUTOTEST”. Example 1: Example 2: low lTE interference. High lTE interference. The lower part of the display shows The lower part of the display shows the the following information: following information:...
Page 66
SPECIAL SPECIAL sAt speciAl functions FUNCT FUNCT noTE: the special functions depend SPECIAL SPECIAL on the active operating mode: FUNCT FUNCT Tv SAT or CATv. BuzzEr & noISE MArGIn GrApH _____________________________ After selected the Satellite and Transponder Touch “SPECIAl FUNCT”, desired press the “HOME”...
optionAl “App ” rEMoTE conTroL _____________________________________________ The REMOTE CONTROL is available only in the PLUS version, because it is equipped with LAN. The SW REMOTE CONTROl application allow to configure and memorized the instruments and all measurements remotely via web browser (PC, TABlET and SMARTPHONE) “DHcp”...
Page 68
Example of “DHCP” remote connection: HD TAB 900 51945 _HD TAB 900_ 1. Open a web browser, 2. Insert the assigned IP, Example 192.168.15.134/index.html, 3. Insert in the “USERNAME” field the name of the instruments (NAME) preceded and followed with symbol_ , Example: _HD TAB 900_, 4.
Page 69
EXAMpLE oF “STATIc” conFIGurATIon. Touch “CONFIGURATION MENU” Touch “METER” and then from “vOlUME” screen. “lAN CONFIGURATION” Touch “IP CONFIG” and select “STATIC”, Touch “CHECK”. insert the “IP”, “NMASK” and “GWAY” parameters. At the end touch “EXIT” to exit. noTE: for more information about the “APP”s, contact your distributor or send an e-mail to: wecare@roverinstruments.com...
Page 70
You will also receive an e-mail message, reminding you of your chosen user name and the • password assigned by ROvER. Keep it in a safe place for future access to the Update SW Area and so that you can download new SW upgrades and/or Memory Plans;...
Meter and click on “upgrade” to carry out the Upgrade manually; 10. Wait a few minutes, the ROvER S.M.A.R.T. program will load the new SW in your Meter; 11. Once the download has been completed, the following message on the PC will appear: power on the meter to activate FW **proGrAM SuccESFuL**;...
Page 72
Connect the USB cable, first to the Meter and then to the PC; Make sure that you have installed the PRO version and start up the ROvER S.M.A.R.T. program in your PC; In the ROvER S.M.A.R.T. PRO program window, click on “Instrument” followed by “Connect Instrument”;...
Page 73
li-ion poliMer BAtteries IMporTAnT: • Do noT LEAvE THE BATTErIES DIScHArGED For LonG pErIoDS; • ALWAyS cHArGE THE BATTErIES AT nIGHT, EvEn IF THEy ArE noT coMpLETELy DIScHArGED. uSEFuL InForMATIon: 1. The batteries supplied are high quality and tested individually, the autonomy depending on the following conditions: •...
BAttery test & BAttery reGenerAtion THIS procEDurE EXpLAInS HoW To rEGEnErATE/cHEcK your BATTErIES AnD cALIBrATE THE BATTEry cHArGE InDIcATor uSEFuL ADvIcE: • Charge the batteries every night after use, even if they are not completely discharged; • Always use the “battery save” & “timer off” functions to increase your meter’s autonomy; •...
Page 75
ALIMENTATORE SPENTO 0,5 SECONDI OFF SPENTO Controllare il trasformatore di alimentazione NON ORIGINALE 0,5 SECONDI ON deve essere 12 Vdc e non 18 Vdc. ROVER LAMPEGGIA IN ACCENSIONE Indiiferente SPENTO Strumento in fase di accensione 15 VOLTE LAMPEGGIANTI Lo Strumento ha rilevato un’anomalia...
Do not use hairdryer or other strong heating sources, but just leave the meter in quiet air. If possible, contact Rover laboratories S.p.A. Technical Assistance.
GuArAnTEE rEGuLATIonS: 1. IMPORTANT: the guarantee is valid only upon the presentation of invoice or receipt to ROvER laboratories S.p.A. The purchase date must be clearly indicated on the invoice/receipt.
Risks and costs for transport to ROvER laboratories S.p.A. must be sustained by the buyer. After repair, if the equipment is under guarantee, ROvER laboratories S.p.A. will pay for the transport returning the goods to the customer. If the instrument is not under guarantee, after repair, the equipment will be returned by courier service with the amount to be paid by the customer shown on the invoice.
Page 79
• IBAN code *: ..............................* Fields noT required for official rovEr dealers (required for any end customer). n.B. please enter the TAX coDE even if it the same as your vAT number. In the case of sole proprietorship, please communicate the name and surname of the owner.
suGGested VAlues This table shows the suggested measurements at a user’s socket for the main digital modulations. � DVB-T2 & GB COFDM dBµV dBµV PE R –7 256 QAM 2 / 3 FEC 26,5 29,5 256 QAM 3 / 4 FEC 28,5 31,5 256 QAM...
• Battery charger power supply • User guide (CD or USB) • F Female - F Female connector LIST oF provIDED AccESSorIES HD TAB 700 Plus : • Rugged Elite BAG • Removeable side pocket for tools and accessories •...
Page 82
ABBreViAtions & tecHnicAl terMs • APID (Audio Packet Identifier): Audio reception parameters in the MPEG data stream. • aBER (Bit Error Rate after Viterbi): Ratio of the transmitted bits to the erroneous bits after Reed Solomon (viterbi). • BCH (Bose Chaudhuri Hocquenghem): External error protection decoder. •...
Page 83
– Get to know your HD TAB 700/700 Plus – Multi-porpose bag – HOME and Navigation CONFIG – Configuration – ScreenShot SAT Measure – Tv Measure – FM Measure CATV – CATv Measure SPECT – SPECTRUM Analyzer OPTIC –...
custoMer support wecare@roverinstruments.com skype ® only for call wecare.roverinstruments UG-HDTAB700ePlUS-EN-v1 Designed & Assembled in Sirmione, Europe. RO.vE.R. lABORATORIES S.p.A. via Parini 2, 25019 Sirmione (BS) Italy tel. +39 030 9198 1 fax +39 030 990 6894 Product specification are subject to change without notice . All trademarks used are properties of their respective owners.
Need help?
Do you have a question about the HD TAB 700 and is the answer not in the manual?
Questions and answers