NEC Express5800/R120g Maintenance Manual page 204

Express server
Table of Contents

Advertisement

Chapter 3 Appendix
Error Message
C301
SDR mismatch error
Hardware configuration
C302
error.
FAN Structure ID command
C303
error.
Necessary to update SDR
C304
Version for new RAID Card.
C310
Hardware configuration of
cooling is insufficient.
C320
Unmatched PSUs.
C321
System power consumption is
out-of-range in PSUs.
C322
No information for system
power consumption check.
C323
Internal Use Area of BMC FRU is
incompatible.
C501
ME is in Recovery Mode.
C600
Internal Flash is not valid.
C624
Invalid internal BIOS
Configuration Data.
C625
BIOS Configuration Data Send
Error.
C626
BIOS Configuration Data Read
Error.
C627
BIOS Configuration Data Write
Error.
C628
System configuration data
cleared by System Boot Options
command.
204
Cause
Inconsistency in the hardware
information of the sensor data
record was detected
Illegal hardware configuration
was detected.
Illegal fan control was detected
when RAID controller is
installed.
SDR for RAID controller is
inappropriate.
Detected that cooling power is
insufficient in this hardware
configuration.
Unmatched power supply units
are configured.
System power consumption
exceeds the power output
capacity limit.
No information is acquired in
checking system power
consumption.
FRU containing the device
information is unmatched.
Intel Node Manager is in
Recovery Mode.
Internal Flash Memory was
specified by a one-time boot
device but could not be
enabled.
Internal error of BIOS
Configuration Data was
detected.
This is an error when BIOS
Configuration Data is sent.
This is a read error on BIOS
Configuration Data.
This is a write error on BIOS
Configuration Data.
The SETUP settings were
cleared by the standard
IPMI-compliant command of
"Set System Boot Options."
Express5800/R120g-2E, T120g Maintenance Guide
Solution
Contact your sales representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. If the same error
is detected repeatedly, contact your sales
representative.
Unplug the power cord, wait for at least 30
seconds, then restart the server. At that time,
check the jumper switch setting on motherboard.
If the same error is detected repeatedly, contact
your sales representative.
Unplug the power cord, wait for at least 30
seconds, and then restart the server.
If the same error is detected repeatedly, contact
your sales representative.
Run SETUP and re-specify each item.
If the problem cannot be solved, contact your
sales representative.
1. POST Error Message

Advertisement

Table of Contents
loading